Serviceline Industrial Sensors
Serviceline Explosion Protection

Inductive sensor NEN40-30GM60-E0

NEN40-30GM60-E0
  • 40 mm non-flush
  • Increased operating distance

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  NEN40-30GM60-E0

General specifications
Switching functionNormally open (NO)
Output typeNPN
Rated operating distance40 mm
Installationnon-flush
Output polarityDC
Assured operating distance0 ... 32.4 mm
Reduction factor rAl 0.42
Reduction factor rCu 0.37
Reduction factor r304 0.78
Nominal ratings
Installation conditions
Ain aluminum: 25 mm
in steel 1.0037 (St37): 35 mm
in brass 25 mm
in stainless steel 20 mm
B55 mm
C120 mm
F150 mm
Operating voltage10 ... 30 V
Switching frequency0 ... 100 Hz
Hysteresis≤ 10 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionpulsing
Voltage drop≤ 2 V
Operating current0 ... 200 mA
Off-state current0 ... 0.1 mA typ. 0.1 µA at 25 °C
No-load supply current≤ 10 mA
Switching state indicatorLED, yellow
Functional safety related parameters
MTTFd211 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Approvals and certificates
CCC approvalCCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection typecable PVC , 2 m
Core cross-section0.34 mm2
Housing materialchromium plated brass
Sensing facePBT
Housing diameter30 mm
Degree of protectionIP67

Documents: NEN40-30GM60-E0

Technical informationLanguageFile TypeFile Size
Installation conditionsENGPDF1053 KB
EinbaubedingungenGERPDF1054 KB
Documents
EPLAN macro EMA / EPLAN Makro EMAALLEMA91 KB

Approvals+Certificates: NEN40-30GM60-E0

Statements of complianceCertificate No.File TypeFile Size
EU-Declaration of conformity / EU-KonformitätserklärungDOC-3027APDF170 KB

Associated Products: NEN40-30GM60-E0

Accessories

Mounting flange, 30 mmfa
VariKont with Active Shielding Technology

The VariKont inductive sensors with Active Shielding Technology ensure high switching distances, no matter the installation situation and the surrounding material. Benefit from easier equipment design and reduced costs!

Inductive Safety Sensors SIL 2 PL d

As the SIL 2/PL d inductive safety sensors have no dead band, data transfer can occur with no minimum distance between sensor and target. Discover the optimized portfolio for demanding environments.