Serviceline
Serviceline Industrial Sensors
Serviceline Explosion Protection

Inductive sensor NJ15-M1-E2-V1

NJ15-M1-E2-V1
  • 15 mm non-flush
  • 3-wire DC

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of NJ15-M1-E2-V1

General specifications
Switching functionNormally open (NO)
Output typePNP
Rated operating distance15 mm
Installationnon-flush
Output polarityDC
Assured operating distance0 ... 12.15 mm
Actual operating distance13.5 ... 16.5 mm typ. 15 mm
Reduction factor rAl 0.39
Reduction factor rCu 0.36
Reduction factor r304 0.73
Nominal ratings
Operating voltage10 ... 60 V DC
Switching frequency0 ... 200 Hz
Hysteresistyp. 5 %
Reverse polarity protectionyes
Short-circuit protectionpulsing
Voltage drop≤ 2.5 V
Voltage drop at IL
Voltage drop IL = 200 mA, switching element on1 ... 2.5 V typ. 2.2 V
Rated insulation voltage500 V
Operating current0 ... 200 mA
No-load supply current≤ 14 mA
Operating voltage indicatorLED, green
Switching state indicatorLED, yellow
Functional safety related parameters
MTTFd932 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Approvals and certificates
EAC conformityTR CU 020/2011
CCC approvalCertified by China Compulsory Certification (CCC)
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection typeConnector M12 x 1 , 4-pin
Housing materialPBT/metal RAL 7011
Sensing facePBT
Degree of protectionIP67

Approvals+Certificates: NJ15-M1-E2-V1

CertificatesCertificate No.File TypeFile Size
Canada USA CSA Ordinary Location1007121PDF99 KB
US CA UL General PurposeE87056LINK---

Associated Products: NJ15-M1-E2-V1

Accessories

Female cordset, M12, 4-pin, PUR cablefa

Female cordset, M12, 4-pin, PUR cablefa