Serviceline
Serviceline Industrial Sensors
Serviceline Explosion Protection

Inductive sensor NBB2-12GM50-E2-T-V1

NBB2-12GM50-E2-T-V1
  • 2 mm flush
  • Extended operating voltage range
  • Extended temperature range

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of NBB2-12GM50-E2-T-V1

General specifications
Switching functionNormally open (NO)
Output typePNP
Rated operating distance2 mm
Installationflush
Output polarityDC
Assured operating distance0 ... 1.62 mm
Actuating elementmild steel, e. g. 1.0037, SR235JR (formerly St37-2)
12 mm x 12 mm x 1 mm
Reduction factor rAl 0.35
Reduction factor rCu 0.2
Reduction factor r304 0.7
Reduction factor rBrass 0.4
Nominal ratings
Operating voltage10 ... 65 V
Switching frequency0 ... 1200 Hz
Hysteresis0.02 ... 0.44
Reverse polarity protectionyes
Short-circuit protectionyes
Overload resistanceyes
Wire breakage protectionyes
Inductive overvoltage protectionyes
Surge suppressionyes
Ripple10 %
Voltage drop≤ 2.5 V
Repeat accuracy0.1 mm
Operating current0 ... 300 mA
Off-state current0.01 mA
No-load supply current≤ 10 mA
Switching state indicatorMultihole-LED, yellow
Functional safety related parameters
MTTFd1510 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Ambient conditions
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Storage temperature-40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Connection type4-pin, M12 x 1 connector
Housing materialbrass, nickel-plated
Sensing facePBT
Housing diameter12 mm
Degree of protectionIP67
Mass20 g

Documents: NBB2-12GM50-E2-T-V1

Technical informationLanguageFile TypeFile Size
Installation conditionsENGPDF191 KB
EinbaubedingungenGERPDF194 KB
warunki montażuPOLPDF245 KB
Условия монтажаRUSPDF274 KB

Approvals+Certificates: NBB2-12GM50-E2-T-V1

CertificatesCertificate No.File TypeFile Size
US CA UL General PurposeE87056LINK---

Associated Products: NBB2-12GM50-E2-T-V1

Accessories

Mounting flange, 12 mmfa

Female cordset, M12, 4-pin, PUR cablefa

Female cordset, M12, 4-pin, PUR cablefa