Serviceline Industrial Sensors
Serviceline Explosion Protection

Inductive sensor NBB2-12GM50-E2-T-V1

NBB2-12GM50-E2-T-V1
  • 2 mm flush
  • Extended operating voltage range
  • Extended temperature range

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  NBB2-12GM50-E2-T-V1

General specifications
Switching functionNormally open (NO)
Output typePNP
Rated operating distance2 mm
Installationflush
Output polarityDC
Assured operating distance0 ... 1.62 mm
Actuating elementmild steel, e. g. 1.0037, SR235JR (formerly St37-2)
12 mm x 12 mm x 1 mm
Reduction factor rAl 0.35
Reduction factor rCu 0.2
Reduction factor r304 0.7
Reduction factor rBrass 0.4
Nominal ratings
Operating voltage10 ... 65 V
Switching frequency0 ... 1200 Hz
Hysteresis0.02 ... 0.44
Reverse polarity protectionyes
Short-circuit protectionyes
Overload resistanceyes
Wire breakage protectionyes
Inductive overvoltage protectionyes
Surge suppressionyes
Ripple10 %
Voltage drop≤ 2.5 V
Repeat accuracy0.1 mm
Operating current0 ... 300 mA
Off-state current0.01 mA
No-load supply current≤ 10 mA
Switching state indicatorMultihole-LED, yellow
Functional safety related parameters
MTTFd1510 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Ambient conditions
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Storage temperature-40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Connection type4-pin, M12 x 1 connector
Housing materialbrass, nickel-plated
Sensing facePBT
Housing diameter12 mm
Degree of protectionIP67
Mass20 g

Documents: NBB2-12GM50-E2-T-V1

Technical informationLanguageFile TypeFile Size
Installation conditionsENGPDF1054 KB
EinbaubedingungenGERPDF1060 KB

Associated Products: NBB2-12GM50-E2-T-V1

Accessories

Mounting flange, 12 mmfa

Female cordset single-ended M12 straight A-coded, 4-pin, PUR cable greyfa

Female cordset single-ended M12 angled A-coded, 4-pin, PUR cable greyfa
VariKont with Active Shielding Technology

The VariKont inductive sensors with Active Shielding Technology ensure high switching distances, no matter the installation situation and the surrounding material. Benefit from easier equipment design and reduced costs!

Inductive Safety Sensors SIL 2 PL d

As the SIL 2/PL d inductive safety sensors have no dead band, data transfer can occur with no minimum distance between sensor and target. Discover the optimized portfolio for demanding environments.