Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH, also apply to Pepperl+Fuchs AG.
Download the complete datasheet as a PDF:
Datasheet excerpt: Technical data of
NBB4-12GM30-E2-5M
General specifications |
Switching function | Normally open (NO) |
Output type | PNP |
Rated operating distance | 4 mm |
Installation | flush |
Output polarity | DC |
Assured operating distance | 0 ... 3.24 mm |
Reduction factor rAl | 0.45 |
Reduction factor rCu | 0.35 |
Reduction factor r304 | 0.7 |
Nominal ratings |
Operating voltage | 10 ... 30 V |
Switching frequency | 0 ... 500 Hz |
Hysteresis | typ. 5% |
Reverse polarity protection | reverse polarity protected |
Short-circuit protection | pulsing |
Voltage drop | ≤ 3 V |
Operating current | 0 ... 150 mA |
Off-state current | 0 ... 0.5 mA typ. 0.1 µA |
| Off-state current TU =40 °C, switching element off | ≤ |
No-load supply current | ≤ 15 mA |
Switching state indicator | LED yellow |
Functional safety related parameters |
MTTFd | 1770 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Approvals and certificates |
UL approval | cULus Listed, General Purpose |
CSA approval | cCSAus Listed, General Purpose |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions |
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
Mechanical specifications |
Connection type | cable PVC , 5 m |
Core cross-section | 0.14 mm2 |
Housing material | brass, nickel-plated |
Sensing face | PBT |
Housing diameter | 12 mm |
Degree of protection | IP67 |
Mass | 30 g |
Documents:
NBB4-12GM30-E2-5M
CAD+CAE:
NBB4-12GM30-E2-5M
Approvals+Certificates:
NBB4-12GM30-E2-5M
Associated Products:
NBB4-12GM30-E2-5M
Accessories |
|
|
|
Mounting flange, 12 mmfa |
|
|
|
|
Quick mounting bracket with dead stopfa |
|