Serviceline Industrial Sensors
Serviceline Explosion Protection

Inductive sensor NBB8-18GM50-E2-M-Y257915

NBB8-18GM50-E2-M-Y257915
  • 8 mm flush
  • Increased operating distance
  • Extended temperature range -40 ... +85 °C
  • e1-Type approval
  • Increased noise immunity 100 V/m

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH, also apply to Pepperl+Fuchs AG.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  NBB8-18GM50-E2-M-Y257915

General specifications
Switching functionNormally open (NO)
Output typePNP
Rated operating distance8 mm
Installationflush
Output polarityDC
Assured operating distance0 ... 6.48 mm
Reduction factor rAl 0.45
Reduction factor rCu 0.4
Reduction factor r304 0.7
Nominal ratings
Operating voltage10 ... 30 V
Switching frequency0 ... 400 Hz
Hysteresistyp. 5 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionpulsing
Voltage drop≤ 2.5 V
Operating current0 ... 200 mA
Off-state current0 ... 0.5 mA typ. 0.1 µA at 25 °C
No-load supply current≤ 10 mA
Switching state indicatorall direction LED, yellow
Functional safety related parameters
MTTFd1630 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated ≤36 V
e1 Type approval2006/28/EG
Ambient conditions
Ambient temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection typeCable connector Deutsch
with PUR cable L = 335 mm ± 10 mm
Connection assembly(1) sensor
(2) Identification Number
(3) cable clip
(4) Schlemmer rubber bushing, 8500495
(5) Schlemmer corrugated tube 120010
(6) Deutsch backshell 1011-259-0305
(7) Deutsch housing DT06-3S-C015
(8) Deutsch contact 1062-16-0622
(9) Deutsch wedge W3S
Core cross-section0.75 mm2
Housing materialbrass, nickel-plated
Sensing facePBT
Housing diameter18 mm
Degree of protectionIP68 / IP69K

Approvals+Certificates: NBB8-18GM50-E2-M-Y257915

CertificatesCertificate No.File TypeFile Size
Canada USA CSA Ordinary Location1007121PDF99 KB
US CA UL General PurposeE87056LINK---

Associated Products: NBB8-18GM50-E2-M-Y257915

Accessories

Mounting flange, 18 mmfa