Serviceline
Serviceline Industrial Sensors
Serviceline Explosion Protection

Inductive ring sensor RC10-14-N3

RC10-14-N3
  • 10 mm inside diameter
  • Bistable
  • Direction detection

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH, also apply to Pepperl+Fuchs AG.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  RC10-14-N3

General specifications
Switching functionNormally closed (NC)
Output typeNAMUR, bistable
Inside diameter10 mm
Measuring cylinder
Diameter2.5 mm
Length3 mm
Measuring cone
Material9S20K
Output type2-wire
Nominal ratings
Nominal voltage8.2 V (Ri approx. 1 kΩ)
Hysteresistyp. 1 %
Reverse polarity protectionreverse polarity protected
Current consumption
Traverse B3 mA
Traverse A1 mA
Time delay before availability≤ 5 ms
Functional safety related parameters
MTTFd2144 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000
IEC 60947-5-6:1999
StandardsEN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Approvals and certificates
FM approval
Control drawing116-0165
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
Ambient conditions
Ambient temperature-20 ... 100 °C (-4 ... 212 °F)
Mechanical specifications
Connection typecable PVC , 2 m
Core cross-section0.14 mm2
Housing materialPBT
Degree of protectionIP67
Cable
Bending radius> 10 x cable diameter
Equipment protection level Gb
CE marking[*PD-Z02585A*]
ATEX markingEx-Hexagon II 2G Ex ia IIC T6…T1 Gb
The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013, EN 60079-11:2012
Ignition protection "Intrinsic safety"
Use is restricted to the following stated conditions
Appropriate typeRC10-...-N3...
Effective internal capacitancemax. 90 nF ; a cable length of 10 m is considered.
Effective internal inductancemax. 120 µH ; a cable length of 10 m is considered.
Maximum permissible ambient temperatureDetails of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EU-type examination certificate.
General information
Use in the hazardous areasee instruction manuals
Category2G

Documents: RC10-14-N3

Instruction manualsLanguageFile TypeFile Size
Instruction manualENGPDF53 KB
Manuel d'instructionsFRAPDF52 KB
BetriebsanleitungGERPDF55 KB
Manuale di istruzioniITAPDF50 KB
Manual de instruccionesSPAPDF52 KB

Approvals+Certificates: RC10-14-N3

Statements of complianceCertificate No.File TypeFile Size
EU-Declaration of conformity / EU-KonformitätserklärungDOC-1257APDF135 KB
Certificates
Canada USA CSA Ordinary Location1007121PDF99 KB
Canada USA UL Ordinary Location20170306-E87056PDF407 KB
EU PTB ATEX ia 2GPTB 99 ATEX 2128 XPDF958 KB
Control drawings
Control Drawing FM / Control Drawing FM   PDF686 KB