Serviceline Industrial Sensors
Serviceline Explosion Protection

Inductive sensor NJ4-30GM-N-200-10M

NJ4-30GM-N-200-10M
  • Temperature range
    0 ... 200 °C (0 ... 392 °F)


NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below:

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  NJ4-30GM-N-200-10M

General specifications
Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance4 mm
Installationflush
Assured operating distance0 ... 3.04 mm
Reduction factor rAl 0.15
Reduction factor rCu 0.05
Reduction factor r304 0.55
Output type2-wire
Nominal ratings
Nominal voltage8.2 V (Ri approx. 1 kΩ)
Switching frequency0 ... 1000 Hz
Hysteresis≤ 20 % at 200°C
Suitable for 2:1 technologyyes , Reverse polarity protection diode not required
Current consumption
Measuring plate not detectedmin. 3 mA
Measuring plate detected≤ 1 mA
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000
IEC 60947-5-6:1999
StandardsEN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Approvals and certificates
IECEx approval
Equipment protection level GaIECEx PTB 11.0037X
Equipment protection level GbIECEx PTB 11.0037X
Equipment protection level DaIECEx PTB 11.0037X
Equipment protection level MbIECEx PTB 11.0037X
ATEX approval
Equipment protection level GaPTB 00 ATEX 2048 X
Equipment protection level GbPTB 00 ATEX 2048 X
Equipment protection level DaPTB 00 ATEX 2048 X
UL approval
Ordinary LocationE87056
Hazardous LocationE501628
Control drawing116-0452
CCC approvalCCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature0 ... 200 °C (32 ... 392 °F)
Mechanical specifications
Connection typecable SIHF , 10 m
Core cross-section0.34 mm2
Housing materialStainless steel 1.4305 / AISI 303
Sensing facePPS
Degree of protectionIP65
Cable
Bending radius> 10 x cable diameter
Noteamplifier -25°C...70°C
2 m PTFE cable between amplifier and oscillator
General information
Use in the hazardous areasee instruction manuals

Documents: NJ4-30GM-N-200-10M

Instruction manualsLanguageFile TypeFile Size
ИнструкцииBULPDF173 KB
Návod k poużitíCZEPDF165 KB
Instruktions manualDANPDF163 KB
Instruction manualENGPDF166 KB
KasutusjuhendESTPDF158 KB
KäyttöohjeFINPDF158 KB
Manuel d'instructionsFRAPDF168 KB
BetriebsanleitungGERPDF165 KB
Οδηγίες χρήσηςGREPDF175 KB
HandleidingHOLPDF164 KB
Instruction manual / BetriebsanleitungHRVPDF163 KB
Használati útmutatóHUNPDF168 KB
Manuale di istruzioniITAPDF166 KB
Lietošanas pamācībaLAVPDF163 KB
Instrukciju vadovasLITPDF164 KB
Instrukcja obsługiPOLPDF167 KB
Manual de instruçõesPORPDF167 KB
Manual de utilizareRONPDF167 KB
Návod na poużitieSLKPDF165 KB
Navodila za uporaboSLVPDF163 KB
Manual de instruccionesSPAPDF168 KB
ManualSWEPDF162 KB

Approvals+Certificates: NJ4-30GM-N-200-10M

Statements of complianceCertificate No.File TypeFile Size
EU-Declaration of conformity / EU-KonformitätserklärungDOC-3559PDF347 KB
Certificates
Canada USA UL Hazardous LocationE501628:1:2PDF444 KB
Canada USA UL Ordinary Location20170306-E87056PDF407 KB
EU PTB ATEX ia 2G, 1G, 1D s. certificatePTB 00 ATEX 2048 XPDF29071 KB
Worldwide PTB IECEx iaIECEx PTB 11.0037XLINK---
Control drawings
Control drawing UL / Control drawing UL   PDF286 KB

Associated Products: NJ4-30GM-N-200-10M

Accessories

Mounting flange, 30 mmfa

Quick mounting bracket with dead stopfa
VariKont with Active Shielding Technology

The VariKont inductive sensors with Active Shielding Technology ensure high switching distances, no matter the installation situation and the surrounding material. Benefit from easier equipment design and reduced costs!

Inductive Safety Sensors SIL 2 PL d

As the SIL 2/PL d inductive safety sensors have no dead band, data transfer can occur with no minimum distance between sensor and target. Discover the optimized portfolio for demanding environments.