Serviceline Industrial Sensors
Serviceline Explosion Protection

Inductive sensor FJ7-N

FJ7-N
  • 7 mm flush


NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below:

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH, also apply to Pepperl+Fuchs AG.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  FJ7-N

General specifications
Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance7 mm
Installationflush
Assured operating distance0 ... 5.67 mm
Reduction factor rAl 0.4
Reduction factor rCu 0.3
Reduction factor r304 0.85
Output type2-wire
Nominal ratings
Nominal voltage8.2 V (Ri approx. 1 kΩ)
Operating voltage5 ... 25 V
Switching frequency0 ... 200 Hz
Hysteresistyp. %
Current consumption
Measuring plate not detected≥ 3 mA at nominal voltage
Measuring plate detected≤ 1 mA at nominal voltage
Switching state indicatorLED, yellow
Functional safety related parameters
MTTFd4080 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000
StandardsEN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Approvals and certificates
FM approval
Control drawing116-0165
CCC approvalCCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Mechanical specifications
Connection typecable PUR , 2 m
Core cross-section0.34 mm2
Housing materialbrass, zinc plated
Sensing facePOM
Degree of protectionIP67
Cable
Bending radius> 10 x cable diameter
General information
Use in the hazardous areasee instruction manuals

Documents: FJ7-N

Instruction manualsLanguageFile TypeFile Size
ИнструкцииBULPDF164 KB
Návod k poużitíCZEPDF156 KB
Instruktions manualDANPDF154 KB
Instruction manualENGPDF156 KB
KasutusjuhendESTPDF150 KB
KäyttöohjeFINPDF150 KB
Manuel d'instructionsFRAPDF158 KB
BetriebsanleitungGERPDF157 KB
Οδηγίες χρήσηςGREPDF166 KB
HandleidingHOLPDF156 KB
Instruction manual / BetriebsanleitungHRVPDF153 KB
Használati útmutatóHUNPDF158 KB
Manuale di istruzioniITAPDF156 KB
Lietošanas pamācībaLAVPDF154 KB
Instrukciju vadovasLITPDF155 KB
Instrukcja obsługiPOLPDF158 KB
Manual de instruçõesPORPDF158 KB
Manual de utilizareRONPDF158 KB
Návod na poużitieSLKPDF156 KB
Navodila za uporaboSLVPDF153 KB
Manual de instruccionesSPAPDF219 KB
ManualSWEPDF153 KB

Approvals+Certificates: FJ7-N

Statements of complianceCertificate No.File TypeFile Size
EU-Declaration of conformity / EU-KonformitätserklärungDOC-3775PDF135 KB
Certificates
EU PTB ATEX ia 2G, 1G, 1D s. certificatePTB 00 ATEX 2032 XPDF29293 KB
Europe Pepperl+Fuchs Certificate ATEX Category 3PF13CERT2895XPDF495 KB
Worldwide PTB IECEx iaIECEx PTB 11.0021XLINK---
Control drawings
Control Drawing FM / Control Drawing FM   PDF686 KB
VariKont with Active Shielding Technology

The VariKont inductive sensors with Active Shielding Technology ensure high switching distances, no matter the installation situation and the surrounding material. Benefit from easier equipment design and reduced costs!

Inductive Safety Sensors SIL 2 PL d

As the SIL 2/PL d inductive safety sensors have no dead band, data transfer can occur with no minimum distance between sensor and target. Discover the optimized portfolio for demanding environments.