Serviceline Industrial Sensors
Serviceline Explosion Protection

Inductive sensor NCN4-12GM40-E2-V1-3G-3D

NCN4-12GM40-E2-V1-3G-3D
  • 4 mm non-flush
  • ATEX-approval for zone 2 and zone 22

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  NCN4-12GM40-E2-V1-3G-3D

General specifications
Switching functionNormally open (NO)
Output typePNP
Rated operating distance4 mm
Installationnon-flush
Output polarityDC
Assured operating distance0 ... 3.24 mm
Actual operating distance3.6 ... 4.4 mm typ. 4 mm
Reduction factor rAl 0.4
Reduction factor rCu 0.36
Reduction factor r304 0.74
Reduction factor rBrass 0.45
Output type3-wire
Nominal ratings
Operating voltage10 ... 30 V DC
Switching frequency0 ... 2200 Hz
Hysteresis3 ... 15 typ. 7 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionpulsing
Voltage drop≤ 3 V
Voltage drop at IL
Voltage drop IL = 200 mA, switching element on1 ... 2 V typ. 1.5 V
Operating current≤ 200 mA
Off-state current0 ... 0.5 mA typ. 0.01 mA
No-load supply current≤ 15 mA
Time delay before availability≤ 100 ms
Switching state indicatorLED, yellow
Functional safety related parameters
MTTFd1517 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
StandardsEN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Approvals and certificates
UL approvalcULus Listed, General Purpose, Class 2 Power Source
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection typeConnector plug M12 x 1 , 4-pin
Housing materialStainless steel 1.4305 / AISI 303
Sensing facePBT
Degree of protectionIP66 / IP67
General information
Scope of delivery2 self locking nuts in scope of delivery
Use in the hazardous areasee instruction manuals

Documents: NCN4-12GM40-E2-V1-3G-3D

Instruction manualsLanguageFile TypeFile Size
ИнструкцииBULPDF156 KB
Návod k poużitíCZEPDF150 KB
Instruktions manualDANPDF149 KB
Instruction manualENGPDF149 KB
KasutusjuhendESTPDF144 KB
KäyttöohjeFINPDF144 KB
Manuel d'instructionsFRAPDF153 KB
BetriebsanleitungGERPDF150 KB
Οδηγίες χρήσηςGREPDF159 KB
HandleidingHOLPDF149 KB
Instruction manual / BetriebsanleitungHRVPDF148 KB
Használati útmutatóHUNPDF151 KB
Manuale di istruzioniITAPDF148 KB
Lietošanas pamācībaLAVPDF148 KB
Instrukciju vadovasLITPDF150 KB
Instrukcja obsługiPOLPDF152 KB
Manual de instruçõesPORPDF151 KB
Manual de utilizareRONPDF149 KB
Návod na poużitieSLKPDF150 KB
Navodila za uporaboSLVPDF148 KB
Manual de instruccionesSPAPDF211 KB
ManualSWEPDF146 KB

CAD+CAE: NCN4-12GM40-E2-V1-3G-3D

CADFile TypeFile Size
3-D model in IGS format / 3-D-Modell im IGS-FormatIGS1153 KB
3-D model in STP format / 3-D-Modell im STP-FormatSTP310 KB

Approvals+Certificates: NCN4-12GM40-E2-V1-3G-3D

Statements of complianceCertificate No.File TypeFile Size
EU-Declaration of conformity / EU-KonformitätserklärungDOC-4118PDF345 KB
Certificates
/cert/cert4467d.pdf20190220-E87056PDF445 KB
Europe Pepperl+Fuchs ATEX Category 3 D CertificatePF15CERT3774XPDF1001 KB
Europe Pepperl+Fuchs ATEX Category 3 G CertificatePF15CERT3754XPDF1015 KB

Associated Products: NCN4-12GM40-E2-V1-3G-3D

Accessories

Mounting flange, 12 mmfa
VariKont with Active Shielding Technology

The VariKont inductive sensors with Active Shielding Technology ensure high switching distances, no matter the installation situation and the surrounding material. Benefit from easier equipment design and reduced costs!

Inductive Safety Sensors SIL 2 PL d

As the SIL 2/PL d inductive safety sensors have no dead band, data transfer can occur with no minimum distance between sensor and target. Discover the optimized portfolio for demanding environments.