Serviceline Industrial Sensors
Serviceline Explosion Protection

Inductive sensor NCB1,5-12GM70-E2-D-V1

NCB1,5-12GM70-E2-D-V1
  • 1.5 mm flush
  • Operating pressure 500 bar, peak pressure 1000 bar
  • For applications in hydraulic cylinder

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  NCB1,5-12GM70-E2-D-V1

General specifications
Switching functionNormally open (NO)
Output typePNP
Rated operating distance1.5 mm
Installationflush
Output polarityDC
Nominal ratings
Operating voltage10 ... 30 V DC
Switching frequency0 ... 600 Hz
Hysteresistyp. 8 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionpulsing
Voltage drop≤ 2 V
Operating current0 ... 200 mA
No-load supply current≤ 10 mA
Limit data
Operating pressure500 bar (7252 psi)
Peak pressure1000 bar (14504 psi)
Functional safety related parameters
MTTFd728 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Mechanical specifications
Connection typeConnector M12 x 1 , 4-pin
Housing materialStainless steel 1.4305 / AISI 303
Sensing faceCeramic
Housing diameter12 mm
Degree of protectionIP68
Mass42 g

Documents: NCB1,5-12GM70-E2-D-V1

Technical informationLanguageFile TypeFile Size
Installation conditionsENGPDF1053 KB
EinbaubedingungenGERPDF1054 KB

Approvals+Certificates: NCB1,5-12GM70-E2-D-V1

Statements of complianceCertificate No.File TypeFile Size
EU-Declaration of conformity / EU-KonformitätserklärungDOC-3028APDF169 KB
Certificates
Canada USA CSA Ordinary Location1007121PDF99 KB
Canada USA UL Ordinary Location20170306-E87056PDF407 KB

Associated Products: NCB1,5-12GM70-E2-D-V1

Accessories

Female cordset, M12, 4-pin, PUR cablefa

Female cordset, M12, 4-pin, PUR cablefa
VariKont with Active Shielding Technology

The VariKont inductive sensors with Active Shielding Technology ensure high switching distances, no matter the installation situation and the surrounding material. Benefit from easier equipment design and reduced costs!

Inductive Safety Sensors SIL 2 PL d

As the SIL 2/PL d inductive safety sensors have no dead band, data transfer can occur with no minimum distance between sensor and target. Discover the optimized portfolio for demanding environments.