Serviceline Industrial Sensors
Serviceline Explosion Protection

Inductive sensor NRN10-12GS40-E2-IO-V1

NRN10-12GS40-E2-IO-V1
  • 10 mm non-flush
  • Reduction factor = 1
  • Magnetic field resistant
  • IO-link interface for service and process data
  • Switch point mode or window mode can be set
  • Switching function, stability alarm and pulse extension can be set

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH, also apply to Pepperl+Fuchs AG.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  NRN10-12GS40-E2-IO-V1

General specifications
Switching functionNormally open/closed (NO/NC) programmable
Output typePNP
Rated operating distance10 mm (factory setting)
Near operating distance8 mm (can be activated by software)
Installationnon-flush
Output polarityDC
Assured operating distance0 ... 8.1 mm
Reduction factor rAl 1
Reduction factor rCu 1
Reduction factor r304 1
Reduction factor rSt37 1
Output type3-wire
Nominal ratings
Operating voltage10 ... 30 V DC
Switching frequency0 ... 1300 Hz (switch point mode)
0 ... 80 Hz (window mode, switch point mode with stability alarm)
Hysteresistyp. 3 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionpulsing
Voltage drop≤ 0.5 V
Operating current0 ... 200 mA
Off-state current0 ... 0.5 mA typ. 60 µA at 25 °C
No-load supply current≤ 15 mA
Time delay before availabilitymax. 150 ms
Constant magnetic field200 mT
Alternating magnetic field200 mT
Status indicatorMultihole-LED, yellow
Functional safety related parameters
MTTFd362 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Interface
Interface typeIO-Link ( via C/Q = pin 4 )
Transfer rateCOM 2 (38.4 kBaud)
IO-Link Revision1.1
Min. cycle time2.3 ms
Process data witdhProcess data input (control system side): 2 Bit
Process data output (control system side): none
SIO mode supportyes
Device ID0x201104 (2101508)
Compatible master port typeA
Compliance with standards and directives
Standard conformity
StandardsEN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Approvals and certificates
Protection classII
Rated insulation voltage60 V
Rated impulse withstand voltage800 V
UL approvalcULus Listed, General Purpose
Class 2 power source
CCC approvalCCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection typeConnector plug M12 x 1 , 4-pin
Housing materialStainless steel 1.4305 / AISI 303
Sensing facePBT
Degree of protectionIP67
Mass24 g
Factory settings
Default settingoperating mode = switch point mode with stability alarm
switching function = Normally open (NO)
switching distance = 10 mm
General information
Scope of delivery2 self locking nuts in scope of delivery

Documents: NRN10-12GS40-E2-IO-V1

ManualsLanguageFile TypeFile Size
Manual Reduction Factor 1 Sensors with IO-LinkENGPDF1772 KB
Handbuch Reduktionsfaktor-1-Sensoren mit IO-LinkGERPDF1687 KB
Technical information
Installation conditionsENGPDF166 KB
Installation conditionsFINPDF269 KB
EinbaubedingungenGERPDF165 KB

CAD+CAE: NRN10-12GS40-E2-IO-V1

CADFile TypeFile Size
3-D model in IGS format / 3-D-Modell im IGS-FormatIGS643 KB
3-D model in STP format / 3-D-Modell im STP-FormatSTP104 KB

Approvals+Certificates: NRN10-12GS40-E2-IO-V1

Statements of complianceCertificate No.File TypeFile Size
EU-Declaration of conformity / EU-KonformitätserklärungDOC-3977APDF206 KB
Certificates
/cert/cert5023.pdfCERT-5023PDF162 KB
Canada USA UL Ordinary Location20190220-E87056PDF406 KB

Associated Products: NRN10-12GS40-E2-IO-V1

Accessories

Mounting flange, 12 mmfa

Quick mounting bracket with dead stopfa

Female cordset, M12, 4-pin, PVC cablefa

Female cordset, M12, 4-pin, PVC cablefa
IO-Link master, supply via USB port or separate power supply, LED indicators, M12 plug for sensor connectionfa