Capacitive sensor CJ10-30GK-WS

CJ10-30GK-WS
  • 10 mm non-flush
  • The switching distance can be set over a wide range with the potentiometer

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH, also apply to Pepperl+Fuchs AG.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  CJ10-30GK-WS

General specifications
Switching functionNormally open (NO)
Output typeTwo-wire
Rated operating distance10 mm
Installationnon-flush
Output polarityAC
Assured operating distance0 ... 7.2 mm
Output type2-wire
Nominal ratings
Installation conditions
A18 mm
B10 mm
C20 mm
F60 mm
Operating voltage20 ... 253 V AC 1)
Switching frequency0 ... 10 Hz
Hysteresis2 ... 10 typ. 5 %
Reverse polarity protectionreverse polarity tolerant
Voltage drop at IL
Voltage drop IL = 100 mA, switching element ontyp. 7 V
Momentary current
(20 ms, 0.1 Hz)
0 ... 1200 mA
Rated insulation voltage1500 V
Operating current5 ... 200 mA
Lowest operating current5 mA
Off-state current0.7 ... 1.5 mA typ.
Time delay before availability≤ 300 ms
Switching state indicatorLED, yellow
Indicators/operating means
Potentiometersensitivity adjustment
Compliance with standards and directives
Standard conformity
StandardsEN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Approvals and certificates
UL approvalcULus Listed, General Purpose
CCC approvalCertified by China Compulsory Certification (CCC)
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Mechanical specifications
Connection typecable PVC , 2 m
Core cross-section0.75 mm2
Housing materialPBT
Sensing facePBT
Degree of protectionIP67
Note1) In the temperature range below 0 °C, permissible operating voltage Ub 80...253 V
Safety fuse ≤ 0.8 A (quick-blow) according to IEC 60127-2 Sheet 1
Recommendation: after a short circuit, check that the device is functioning correctly.

Documents: CJ10-30GK-WS

Technical informationLanguageFile TypeFile Size
Installation conditionsENGPDF219 KB
EinbaubedingungenGERPDF345 KB

Approvals+Certificates: CJ10-30GK-WS

CertificatesCertificate No.File TypeFile Size
Canada USA CSA Ordinary Location1007121PDF99 KB
Canada USA UL Ordinary Location20170306-E87056PDF407 KB

Associated Products: CJ10-30GK-WS

Accessories

Mounting flange, 30 mmfa