Connection module for RS-232 and RS-485 enabled devices
Electrical specifications
Operating voltage10 ... 30 V DC PELV
Current consumptionmax. 2.5 A
Interface
Physical RS-485
Transfer rate9.6; 19.2; 93.75; 187.5; 500; 1500 kBit/s
3; 6; 12 Mbit/s self-synchronizing
Compliance with standards and directives
Directive conformity89/336 EWG
Standard conformity
Noise immunityEN 61000-6-2
Degree of protectionEN 60529
Shock and impact resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6
Ambient conditions
Relative humidity90 % , noncondensing
Mechanical specifications
Degree of protectionIP40
Connection25-pin Sub-D socket for Barcode scanner ,
M16 cable gland for system connection (5x) ,
9-pin Sub-D socket for PROFIBUS interface

Documents: CBX800-KIT-B6

ManualsLanguageFile TypeFile Size
Manual CBX800ENGPDF1535 KB
Manual DAD DriverENGPDF604 KB
Manual Host Interface ModulesENGPDF1556 KB

Software: CBX800-KIT-B6

DriversRelease InfoFile TypeFile Size
GSD file for Interface box / GSD-File für AnschaltboxV 1.1ZIP14 KB
Software Tools
Genius Software / Genius SoftwareV. 1.16ZIP95060 KB

Function: CBX800-KIT-B6

Devices from the CBX* series enable RS-232 and RS-485-compatible devices to be connected quickly and easily. A wide variety of connections also allows other field devices to be connected.

By reducing installation time and the number of system failures when a device is replaced, your operating costs will be significantly lower.

Standardized pinning of connections and simple attachment of cable ends using spring terminals ensures easy cable installation.

To facilitate installation of the device, the continuous mounting holes are easy to access and the top section of the housing can be removed.