Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Download the complete datasheet as a PDF:
General specifications | ||
---|---|---|
Signal type | Digital Input | |
Supply | ||
Connection | Power Rail or terminals 11+, 12- | |
Rated voltage | 20 ... 30 V DC | |
Input | ||
Connection side | field side | |
Connection | terminals 1 (mass), 2 (min), 3 (max) | |
Open circuit voltage/short-circuit current | approx. 10 V AC (approx. 1 Hz) / approx. 5 mA | |
Control input | min./max. control system: terminals 1, 2, 3 on/off control system: terminals 1, 3 |
|
Response sensitivity | 5 ... 150 kΩ , adjustable via potentiometer (20 turns) | |
Output | ||
Connection side | control side | |
Connection | terminals 7, 8, 9 | |
Output | 1 changeover contact | |
Contact loading | 253 V AC/2 A/cos φ > 0.7; 40 V DC/2 A resistive load | |
Energized/De-energized delay | approx. 1 s / approx. 1 s | |
Galvanic isolation | ||
Input/Output | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff | |
Input/power supply | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff | |
Output/power supply | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff | |
Indicators/settings | ||
Display elements | LEDs | |
Control elements | DIP-switch potentiometer |
|
Configuration | via DIP switches via potentiometer |
|
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Low voltage | ||
Directive 2014/35/EU | EN 61010-1:2010 | |
Conformity | ||
Electromagnetic compatibility | NE 21:2006 | |
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals , max. 2.5 mm2 | |
Mass | approx. 110 g | |
Dimensions | 20 x 107 x 115 mm (0.8 x 4.2 x 4.5 inch) , housing type B1 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Indication and operation | ||
Control elements | switch S1 Position I open circuit current: In the open circuit current principle, the relay becomes active when the limit is reached. Position II closed circuit current: In closed circuit current principle, the relay is activated when power is applied. The relay is deactivated when the limit is reached. |
|
General information | ||
Supplementary information | Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Manuals | Language | File Type | File Size |
---|---|---|---|
Manual Signal Conditioners K-System | ENG | 694 KB | |
Handbuch Signaltrenner K-System | GER | 698 KB | |
Manual Signal Conditioners K-System | RUS | 3736 KB | |
Instruction manuals | |||
Инструкции | BUL | 53 KB | |
Návod k poużití | CZE | 47 KB | |
Instruktions manual | DAN | 47 KB | |
Instruction manual | ENG | 41 KB | |
Kasutusjuhend | EST | 44 KB | |
Käyttöohje | FIN | 44 KB | |
Manuel d'instructions | FRA | 79 KB | |
Betriebsanleitung | GER | 43 KB | |
Οδηγίες χρήσης | GRE | 55 KB | |
Handleiding | HOL | 56 KB | |
Instruction manual / Betriebsanleitung | HRV | 55 KB | |
Használati útmutató | HUN | 55 KB | |
Manuale di istruzioni | ITA | 77 KB | |
Lietošanas pamācība | LAV | 54 KB | |
Instrukciju vadovas | LIT | 55 KB | |
Instrukcja obsługi | POL | 57 KB | |
Manual de instruções | POR | 56 KB | |
Manual de utilizare | RON | 56 KB | |
Návod na poużitie | SLK | 115 KB | |
Manual de instrucciones | SPA | 79 KB | |
Manual | SWE | 53 KB |
CAD | File Type | File Size | |
---|---|---|---|
CAD Portal / CAD Portal | LINK | --- | |
Dimension drawing 2-D (DXF) / Abmessungszeichnung 2-D (DXF) | ZIP | 450 KB | |
Dimension drawing 3-D in IGS format / Abmessungszeichnung 3-D im IGS-Format | IGS | 118 KB | |
Dimension drawing 3-D in STP format / Abmessungszeichnung 3-D im STP-Format | STP | 105 KB | |
EPLAN | |||
EPLAN Data Portal / EPLAN Data Portal | LINK | --- | |
EPLAN macro P+F.KFD2-ER-1.6 / EPLAN-Makro P+F.KFD2-ER-1.6 | EDZ | 56 KB |
Statements of compliance | Certificate No. | File Type | File Size |
---|---|---|---|
EU-Declaration of conformity / EU-Konformitätserklärung | DOC-3574 | 80 KB |
Matching System Components | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
Accessories | ||||||
|
This signal conditioner provides the AC measuring voltage for the levelsensing electrodes.
Once the measured medium reaches the electrodes, the unit reacts by energizing a form C changeover relay contact.
The module is voltage and temperature stabilized and guarantees defined switching characteristics. An electronic holding circuit is used that allows minimum/maximum control. Since the conductance of the media may vary, the relay response sensitivity is adjustable.
The normal output state can be reversed through the mode of operation switch S1.