Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Download the complete datasheet as a PDF:
Product Description | ||
---|---|---|
Single head system |
General specifications | ||
---|---|---|
Sensing range | 80 ... 2000 mm | |
Adjustment range | 100 ... 2000 mm | |
Dead band | 0 ... 80 mm | |
Standard target plate | 100 mm x 100 mm | |
Transducer frequency | approx. 175 kHz | |
Response delay | ≤ 150 ms | |
Indicators/operating means | ||
LED green | solid green: monitoring system green flashing: program function |
|
LED yellow | solid yellow: object in the evaluation range yellow, flashing: program function, object detected |
|
LED red | flashing: normal mode: error Program function: no object detected permanently: Program mode, object uncertain |
|
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC , ripple 10 %SS | |
No-load supply current | ≤ 55 mA | |
Input/Output | ||
Synchronization | 1 synchronous input 0-level: -UB...+1 V 1-level: +4 V...+UB input impedance: > 12 KOhm synchronization pulse: 0,1 ... 28 ms |
|
Synchronization frequency | ||
Common mode operation | max. 33 Hz | |
Multiplex operation | ≤ 33 / n Hz, n = number of sensors | |
Input | ||
Input type | 1 program input lower evaluation limit A1: -UB ... +1 V, upper evaluation limit A2: +4 V ... +UB input impedance: > 4.7 kΩ, pulse duration: ≥ 1 s |
|
Output | ||
Output type | 1 analog output 4 ... 20 mA | |
Default setting | evaluation limit A1: 100 mm evaluation limit A2: 2000 mm | |
Resolution | 0.5 mm | |
Deviation of the characteristic curve | ± 1 % of full-scale value | |
Repeat accuracy | ± 0.1 % of full-scale value | |
Load impedance | 0 ... 300 Ohm | |
Temperature influence | ± 1.5 % of full-scale value | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated ≤36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Connection type | Connector M12 x 1 , 5-pin | |
Degree of protection | IP65 | |
Material | ||
Housing | ABS | |
Transducer | epoxy resin/hollow glass sphere mixture; polyurethane foam | |
Mass | 100 g |
Instruction leaflets | Language | File Type | File Size |
---|---|---|---|
Instruction leaflet / Beipackzettel | ALL | 143 KB | |
Documents | |||
Application report - Ultrasonic Technology - Ultrasonic Sensors Regulate Material Feed | ENG | 224 KB | |
Applikationsbericht - Ultraschalltechnologie - Ultraschallsensor regelt Materialzufuhr | GER | 236 KB |
CAD | File Type | File Size | |
---|---|---|---|
3-D model in IGS format / 3-D-Modell im IGS-Format | IGS | 207 KB | |
3-D model in STP format / 3-D-Modell im STP-Format | STP | 140 KB | |
CAD Portal / CAD Portal | LINK | --- | |
EPLAN | |||
EPLAN Data Portal / EPLAN Data Portal | LINK | --- | |
EPLAN macro EDZ / EPLAN Makro EDZ | EDZ | 61 KB |
Statements of compliance | Certificate No. | File Type | File Size |
---|---|---|---|
EU-Declaration of conformity / EU-Konformitätserklärung | DOC-2595A | 238 KB | |
Certificates | |||
Canada USA CSA Ordinary Location | 1007121 | 99 KB | |
US CA UL General Purpose | E87056 | LINK | --- |
Accessories | ||||||
---|---|---|---|---|---|---|
|
||||||
|