Serviceline
Serviceline Industrial Sensors
Serviceline Explosion Protection

Connection cable V15-G-2M-PUR-CAN-V15-G

V15-G-2M-PUR-CAN-V15-G
  • Suitable for DeviceNet and CANopen
  • Shield connected to pin 1
  • Knurled nut suitable for tool assembly
  • Immunity to vibration, with mechanical latching
  • Halogen-free

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of V15-G-2M-PUR-CAN-V15-G

Product Description
DeviceNet/CANOpen bus cable, M12 to M12, PUR cable 5-pin
General specifications
Number of pins5
Connection 1socket
Construction type 1straight
Threading 1M12
Connection 2Male connector
Construction type 2straight
Threading 2M12
Electrical specifications
Operating voltagemax. 60 V DC
Operating currentmax. 4 A
Volume resistance< 5 mΩ
Ambient conditions
Ambient temperature-25 ... 90 °C (-13 ... 194 °F)
cable, fixed: -40 ... 80 °C (-40 ... 176 °F)
cable, flexing: -20 ... 75 °C (-4 ... 167 °F)
Pollution degree3
Mechanical specifications
Contact elementsspring-loaded contact socket
Pin diameter1 mm
Degree of protectionIP65/IP67
Material
ContactsCuSn
Contact surfaceNi/Au
BodyTPU, black
CablePUR
Slotted nutZinc die-casting, nickel-plated
Sleeve connectorZinc die-casting, nickel-plated
SealNBR
Core insolationPE
Cable2 pairs, each with 2 leads, wrapped around a drain wire
Sheath diameter∅ 6.7 mm
Bending radius> 10 x cable diameter, moving
Colorviolet
Cores2 x 0.2 mm2 (signal wire)
2 x 0.32 mm2 (power supply)
1 x 0.32 mm2 (drain wire)
Conductor construction19 x 0.12 mm ∅ (signal wire)
19 x 0.15 mm ∅ (power supply)
Shieldgrid
Tin-plated copper wires, 70 % coverage
Length2 m
Flammability
Housing94 HB

Associated Products: V15-G-2M-PUR-CAN-V15-G

Accessory of

E1-Type approval, Measuring range 0 ... 360°, High shock resistance, Extended temperature range
-40 ... +85 °C, CANopen interface, Increased noise immunity 100 V/mfa

E1-Type approval, Measuring range 0 ... 360°, High shock resistance, Extended temperature range
-40 ... +85 °C, CANopen interface, Increased noise immunity 100 V/mfa

Read head for incident light positioning system, Non-contact positioning on Data Matrix code tape, Mechanically rugged: no wearing parts, long operating life, maintenance-free, High resolution and precise positioning, especially for facilities with curves and switch points as well as inclines and declines., Travel ranges up to 10 km, in X and Y direction, CANopen interfacefa
Sturdy housing, High accuracy of ≤ ± 0,15°, Communication via MODBUS RTU, 1-axis with 360° measuring rangefa
Sturdy housing, High accuracy of ≤ ± 0,15°, Communication via MODBUS RTU, 2-axis with ±80° measuring rangefa
Sturdy housing, High accuracy of ≤ ± 0,15°, Communication via MODBUS RTU, 2-axis with ±80° measuring rangefa
Sturdy housing, High accuracy of ≤ ± 0,15°, Communication via MODBUS RTU, 1-axis with 360° measuring rangefa
E1-Type approval, Measuring range 0 ... 360°, High shock resistance, Extended temperature range
-40 ... +85 °C, CAN bus with SAE J1939 protocolfa
Sturdy housing, High accuracy of ≤ ± 0,15°, CANopen interface, 2-axis with ±80° measuring rangefa
Sturdy housing, High accuracy of ≤ ± 0,15°, CANopen interface, 2-axis with ±80° measuring rangefa
Sturdy housing, High accuracy of ≤ ± 0,15°, CANopen interface, 1-axis with 360° measuring rangefa
Sturdy housing, High accuracy of ≤ ± 0,15°, CANopen interface, 1-axis with 360° measuring rangefa
E1-Type approval, High shock resistance, Extended temperature range
-40 ... +85 °C, Measuring range -60° ... +60°, CAN bus with SAE J1939 protocolfa
E1-Type approval, High shock resistance, Extended temperature range
-40 ... +85 °C, CANopen interface, Measuring range -15° ... +15°, Increased noise immunity 100 V/mfa
E1-Type approval, High shock resistance, Extended temperature range
-40 ... +85 °C, Measuring range -15° ... +15°, CAN bus with SAE J1939 protocolfa
E1-Type approval, Measuring range 0 ... 360°, High shock resistance, Extended temperature range
-40 ... +85 °C, CAN bus with SAE J1939 protocolfa
Inertial measurement unit 6-axis, Measurement of inclination, acceleration and rotation rate in 3 axes each, Compensation of dynamic disturbance, F99-Fusion technology, CAN bus with SAE J1939 protocol, High EMC resistancefa
Read head for incident light positioning system, Mechanically rugged: no wearing parts, long operating life, maintenance-free, CANopen interface, Noncontact lane tracking of a colored strip, Noncontact positioning along the colored strip using Data Matrix codes, Reading of Data Matrix control codesfa
Read head for incident light positioning system, Mechanically rugged: no wearing parts, long operating life, maintenance-free, CANopen interface, Reading of Data Matrix control codes, Non-contact positioning on Data Matrix code tape, Infrared lightfa
Read head for incident light positioning system, Mechanically rugged: no wearing parts, long operating life, maintenance-free, CANopen interface, Reading of Data Matrix control codes, Non-contact positioning on Data Matrix code tape, Infrared lightfa
Read head for incident light positioning system, Non-contact positioning on Data Matrix code tape, Mechanically rugged: no wearing parts, long operating life, maintenance-free, High resolution and precise positioning, especially for facilities with curves and switch points as well as inclines and declines., Travel ranges up to 10 km, in X and Y direction, CANopen interfacefa
Read head for incident light positioning system, Non-contact positioning on Data Matrix code tape, Mechanically rugged: no wearing parts, long operating life, maintenance-free, High resolution and precise positioning, especially for facilities with curves and switch points as well as inclines and declines., Travel ranges up to 10 km, in X and Y direction, CANopen interfacefa