AS-Interface actuator module VAA-4A-G4-E2

VAA-4A-G4-E2
  • AS-Interface certificate
  • Degree of protection IP67
  • Flat or round cable connection (via standardized EEMS base, not included with delivery)
  • Cable piercing method for flat cable
  • Communication monitoring, turn-off
  • Power supply of outputs from the external auxiliary voltage
  • Function display for bus and outputs

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Datasheet excerpt: Technical data of  VAA-4A-G4-E2

Product Description
G4 module IP67
4 electronic outputs (PNP)
General specifications
Node typeStandard node
UL File NumberE87056
Indicators/operating means
LED AS-iAS-Interface voltage; LED green
LED OUTSwitching state (output); 4 LED yellow
Electrical specifications
Auxiliary voltage (output)24 V DC ± 15 % PELV
Rated operating voltage26.5 ... 31.6 V from AS-Interface
Rated operating current≤ 60 mA
Protection classIII
Output
Number/Type4 electronic outputs, PNP
Supplyfrom external auxiliary voltage UAUX
Current1.5 A per output, 4 A total
Voltage≥ (UAUX - 0.5 V)
Programming instructions
ProfileS-8.0
IO code8
ID code0
Data bits (function via AS-Interface) input output
D0 - OUT1
D1 - OUT2
D2 - OUT3
D3 - OUT4
Parameter bits (programmable via AS-i)function
P0communication monitoring
P0 = 1 (default settings), monitoring = ON, i.e. if communication fails, the outputs are de-energised
P0 = 0, monitoring = OFF, if communication fails, the outputs maintain their condition
P1not used
P2not used
P3not used
Ambient conditions
Ambient temperature-25 ... 60 °C (-13 ... 140 °F)
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Mechanical specifications
Degree of protectionIP67 according to EN 60529
ConnectionInsulation penetration technique or terminal compartment
yellow flat cable/black flat cable or standard round cable
Outputs: M12 x 1.5 cable gland and cage tension spring terminals
Mass180 g
MountingDIN rail or screw mounting

Classifications

SystemClasscode
ECLASS 13.027242604
ECLASS 12.027242604
ECLASS 11.027242604
ECLASS 10.0.127242604
ECLASS 9.027242604
ECLASS 8.027242604
ECLASS 5.127242604
ETIM 9.0EC001599
ETIM 8.0EC001599
ETIM 7.0EC001599
ETIM 6.0EC001599
ETIM 5.0EC001599
UNSPSC 12.139121535

Details: VAA-4A-G4-E2

Datasheet: VAA-4A-G4-E2

DatasheetFile TypeFile Size
Datasheet VAA-4A-G4-E2PDF270 KB
Fiche de données VAA-4A-G4-E2PDF283 KB
Datenblatt VAA-4A-G4-E2PDF199 KB

CAD+CAE: VAA-4A-G4-E2

CADFile TypeFile Size
CAD 3-D / CAD 3-DSTP2960 KB

Associated Products: VAA-4A-G4-E2

Matching System Components

AS-Interface module mounting base with adressing jack for connection to flat cable (AS-Interface and external auxiliary power)fa
AS-Interface module mounting base for connection to flat cable (AS-Interface and external auxiliary power)fa
Accessories

AS-Interface Handheld with accessoryfa
Blind plug M12fa
Free Download: White Paper on TCP-Based Communication Protocols (PDF)

This free PDF white paper compares the different TCP-based communication protocols (AMQP, OPC UA, MQTT, REST API) that have found their way up and are considered the enablers of IIoT and Industry 4.0. Get your free download now!

AS-Interface Switch Cabinet Module KE5 – Simple Handling and Improved Manageability

The unique housing design of the new KE5 switch cabinet module enables distinct visibility and simplifies mounting, wiring, and maintenance inside switch cabinets and junction boxes.

AS-Interface Product Range

Get to know our full range of AS-Interface products.