Inclination sensor INY360D-F99-B20-V15

INY360D-F99-B20-V15
  • E1-Type approval
  • Measuring range 0 ... 360°
  • High shock resistance
  • Extended temperature range
    -40 ... +85 °C
  • CAN bus with SAE J1939 protocol

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH, also apply to Pepperl+Fuchs AG.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  INY360D-F99-B20-V15

General specifications
TypeInclination sensor, 2-axis
Measurement range0 ... 360 °
Absolute accuracy≤ ± 0.5 °
Response delay≤ 25 ms
Resolution≤ 0.1 °
Repeat accuracy≤ ± 0.1 °
Temperature influence≤ 0.027 °/K
Functional safety related parameters
MTTFd650 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Indicators/operating means
Operation indicatorLED, green
Status indicatorLED, yellow
Error indicatorLED, red
Electrical specifications
Operating voltage5 ... 30 V DC
No-load supply current≤ 100 mA
Power consumption≤ 0.7 W
Interface
Interface typeJ1939
Data output codebinary code
Transfer rate10 ... 1000 kBit/s , programmable
Node ID0 ... 253 , programmable
Terminationexternal
Cycle timeprogrammable
SLOT Range0 ... 359.99 °
SLOT Offset0 °
Compliance with standards and directives
Standard conformity
Shock and impact resistance100 g according to DIN EN 60068-2-27
StandardsEN 60947-5-2:2007
IEC 60947-5-2:2007
Approvals and certificates
UL approvalcULus Listed, Class 2 Power Source
CSA approvalcCSAus Listed, General Purpose, Class 2 Power Source
E1 Type approval10R-04
Ambient conditions
Ambient temperature-40 ... 85 °C (-40 ... 185 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type5-pin, M12 x 1 connector
5-pin, M12 x 1 socket
internal bridged
Housing materialPA
Degree of protectionIP68 / IP69K
Mass240 g
Factory settings
Node ID128
Transfer rate250 kBit/s

Documents: INY360D-F99-B20-V15

ManualsLanguageFile TypeFile Size
Manual Inclination Sensor CAN Bus with J1939 ProtocolENGPDF1468 KB

CAD+CAE: INY360D-F99-B20-V15

CADFile TypeFile Size
3-D model in IGS format / 3-D-Modell im IGS-FormatIGS2767 KB
3-D model in STP format / 3-D-Modell im STP-FormatSTP842 KB
CAD Portal / CAD PortalLINK---

Approvals+Certificates: INY360D-F99-B20-V15

Statements of complianceCertificate No.File TypeFile Size
EU-Declaration of conformity / EU-KonformitätserklärungDOC-0724CPDF169 KB
Certificates
Canada USA CSA Ordinary Location1007121PDF99 KB
US CA UL General PurposeE87056LINK---

Associated Products: INY360D-F99-B20-V15

Accessories
DeviceNet/CANOpen bus cable, M12 to M12, PUR cable 5-pinfa
DeviceNet/CANOpen bus cable, M12 to M12, PUR cable 5-pinfa
DeviceNet/CANOpen bus cable, M12 to M12, PUR cable 5-pinfa
Y distributor, M12 socket on M12 connector/socketfa