Serviceline Industrial Sensors
Serviceline Explosion Protection

AS-Interface Handheld VBP-HH1-V3.0-V1

VBP-HH1-V3.0-V1
  • Addressing and programming AS-Interface nodes
  • Displaying the assigned node addresses and the status of the inputs
  • Setting outputs at the AS-Interface node
  • Also supports profiles S-7.7.A.7 (Spec 3.0), S-0.B and S-7.B (AS Interface Safety at Work)
  • The node connection is short-circuit and overload proof
  • Additional M12 plug for external power supply for AS-Interface and AUX
  • Connecting cable included with delivery
  • Battery charger included with delivery

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  VBP-HH1-V3.0-V1

Product Description
AS-Interface Handheld
General specifications
AS-Interface specificationV3.0
Operating modePlug-in charging unit, 230 V AC, included in the delivery package
Indicators/operating means
DisplayLC display
Keyboardmembrane keys, 5 keys
Electrical specifications
Operating duration8 h or ≥ 250 read/write procedures for fully charged battery
Power supplybattery mode, please use only battery charger included with delivery to charge (charging time about 14 h)
Interface
Interface typeAS-Interface, short-circuit and overload protected
Open loop voltage28 V (internal power supply)
Load current100 mA at 25 V (internal power supply)
Interface 2
Interface typeM12 connector for external power supply
Physical AUX: 24 V PELV, 2 A (not short-circuit proof)
AS-Interface: 31,6 V PELV (DC or AS-Interface), 200 mA (short-circuit proof)
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUHandheld: EN 61326-1:2013
Plug-in charging unit EN 61000-3-2:2014 , EN 61000-3-3:2013 , EN 61000-4-2:2009 , EN 61000-4-3:2006+A1:2008+A2:2010, EN 61000-4-4:2012, EN 61000-4-5:2014+A1:2017, EN 61000-4-6:2014+AC:2015, EN 61000-4-8:2010, EN 61000-4-11:2004+A1:2017 , EN 55032:2015+AC:2016 , EN 55035:2017
Low voltage
Directive 2014/35/EUPlug-in charging unit EN 62368-1:2014+A11:2017
Standard conformity
Degree of protectionEN 60529:2000
Electrical safetyPlug-in charging unit EN 62368-1:2014+A11:2017
Emitted interferenceHandheld: EN 61326-1:2013
Plug-in charging unit EN 55032:2015+AC:2016 , EN 55035:2017
Noise immunityHandheld: EN 61326-1:2013
Plug-in charging unit EN 61000-3-2:2014 , EN 61000-3-3:2013
Ambient conditions
Ambient temperature0 ... 40 °C (32 ... 104 °F)
Storage temperature-20 ... 40 °C (-4 ... 104 °F)
Mechanical specifications
Degree of protectionIP20
Material
Housingplastic
Massapprox. 610 g
Dimensions
Height34 mm
Width80 mm
Length214 mm

Classifications

SystemClasscode
ECLASS 13.027242692
ECLASS 12.027242692
ECLASS 11.027242692
ECLASS 10.0.127242692
ECLASS 9.027242692
ECLASS 8.027279212
ECLASS 5.127279212
ETIM 9.0EC003015
ETIM 8.0EC003015
ETIM 7.0EC003015
ETIM 6.0EC003015
ETIM 5.0EC003015
UNSPSC 12.139121535

Details: VBP-HH1-V3.0-V1

Function

The AS-Interface handheld VBP-HH1-V3.0-V1 is an addressing device according to ASInterface specification 3.0.

This addressing device is used to program AS-Interface slaves and for function testing purposes.

In addition, the following new functionalities have been integrated:

  • Permanent data interchange with AS-Interface slaves

  • Support of the data interchange with 4E4A slaves in ext. addressing mode

  • Display of the safety code for AS-Interface Safety at Work slaves

The AS-Interface connection adapter on the top of the addressing device is used for the connection of AS-Interface slaves (sensors, actuators and modules) to the addressing device. The following devices and models can be connected via a plug connection on the AS-Interface connection adapter to the addressing device:

devices with M12 plug, VariKont M system, VariKont system, FP model, AS-Interface module of models G1, G4, G16.

Please use the adapter cable VAZ-PK-1,5M-V1-G (included in the scope of delivery) for device models with integrated addressing jacks.

There is an additional M12 plug on the front side of the housing. It provides a connection possibility with external auxiliary voltage AUX for slaves, which expect this at the connection adapter. Due to the integrated decoupling coil it is also possible to connect DC- or AS-Interface voltage to energize the slave directly and to relieve the internal battery.

A connection cable for the extension is included in the scope of delivery.

Product Documentation: VBP-HH1-V3.0-V1

Language Selection:
Brief InstructionsLanguageFile TypeFile Size
Brief Instructions - VBP-HH1-V3.0*ENGPDF2006 KB
Manuals
Manual VBP-HH1-V3.0*ENGPDF4223 KB

Approvals: VBP-HH1-V3.0-V1

Language Selection:
Declaration of ConformityCertificate No.LanguageFile TypeFile Size
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-2412EALLPDF108 KB
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F)DOC-7018ALLPDF106 KB

Associated Products: VBP-HH1-V3.0-V1

Accessories

Adapter cable module/hand-held programming devicefa
T-Splitter M12 plug to M12 plug / M12 socket 4-pin A-codedfa
Adapter cable G10 module/hand-held programming devicefa
Adapter cable G20 module/hand-held programming devicefa
Free Download: White Paper on TCP-Based Communication Protocols (PDF)

This free PDF white paper compares the different TCP-based communication protocols (AMQP, OPC UA, MQTT, REST API) that have found their way up and are considered the enablers of IIoT and Industry 4.0. Get your free download now!

AS-Interface Product Range

Get to know our full range of AS-Interface products.