Serviceline Industrial Sensors
Serviceline Explosion Protection

Voltage limiter VAZ-G10-LIMITER

VAZ-G10-LIMITER
  • One piece housing
  • Simple and fast mounting
  • Limitation of the voltage feedback
  • Gold-plated and machined contacts
  • Degree of protection IP68 / IP69K

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  VAZ-G10-LIMITER

Product Description
Voltage limiter G10
General specifications
Construction typeFlat cable terminals
Electrical specifications
Rated operating voltage24 V DC ± 10 % PELV
Protection classIII
Compliance with standards and directives
Standard conformity
Degree of protectionEN 60529:2000
Ambient conditions
Ambient temperature-25 ... 50 °C (-13 ... 122 °F)
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Pollution degree3
Mechanical specifications
Degree of protectionIP67
IP67 / IP68 / IP69K with flat cable VAZ-FK-S-*
ConnectionFlat cable: cable piercing method
Material
ContactsCuSn / Au
HousingPBT
Mounting screwStainless steel 1.4305 / AISI 303
Mass40 g
Tightening torque, fastening screws1.65 Nm
Dimensions
Height22 mm
Width27.7 mm
Length40.5 mm

Classifications

SystemClasscode
ECLASS 13.027242692
ECLASS 12.027242692
ECLASS 11.027242692
ECLASS 10.0.127242692
ECLASS 9.027242692
ECLASS 8.027279212
ECLASS 5.127279212
ETIM 9.0EC003015
ETIM 8.0EC003015
ETIM 7.0EC003015
ETIM 6.0EC003015
ETIM 5.0EC003015
UNSPSC 12.139121535

Details: VAZ-G10-LIMITER

Function

Motor rollers that regenerate braking energy increase the voltage on the connecting cable when switching off. The VAZ-G10-LIMITER limits the voltage on the supply line so that there is no power supply switch-off or error message. The energy is absorbed in the VAZ-G10-LIMITER. The design depends on the speed of the motor rollers, the load, the type of motor rollers and the ambient temperature.

The maximum energy absorption per LIMITER is indicated in the performance diagram. For a given weight of the individual masses transported and given transport speed of the rollers, the maximum permissible number of braking operations on the monitored supply line per LIMITER can be read off. The maximum permissible number can be increased by connecting additional LIMITERS.

A VAZ-G10-LIMITER can buffer at least 2 motor rollers.

Design / Simulation: VAZ-G10-LIMITER

Language Selection:
CADLanguageFile TypeFile Size
CAD 3-D / CAD 3-DALLSTP137 KB

Approvals: VAZ-G10-LIMITER

Language Selection:
Declaration of ConformityCertificate No.LanguageFile TypeFile Size
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-4489AALLPDF214 KB

Associated Products: VAZ-G10-LIMITER

Accessory of
G20 module for digital inputs/outputs, 3 inputs and 3 outputsfa
G20 module for digital inputs/outputs, 4 inputs and 3 outputsfa
G20 module for digital inputs/outputs, 4 inputs and 3 outputsfa
G20 motor control module for Interroll EC310, Interroll EC5000 24V AI, Rulmeca BL3, Itoh Denki PM500XK, Itoh Denki PM500XC, PULSEROLLER Senergy-IDCfa
G20 motor control module for Interroll EC310, Interroll EC5000 24V AI, Rulmeca BL3, Itoh Denki PM500XK, Itoh Denki PM500XC, PULSEROLLER Senergy-IDCfa
G20 motor control module for Itoh Denki PM500XE and PM500XPfa
G20 motor control module for Interroll EC310, Interroll EC5000 24V AI, Rulmeca BL3, Itoh Denki PM500XK, Itoh Denki PM500XC, Winroller WIN50 Series DC, PULSEROLLER Senergy-IDCfa
G20 motor control module for Interroll EC5000 48V AIfa
Free Download: White Paper on TCP-Based Communication Protocols (PDF)

This free PDF white paper compares the different TCP-based communication protocols (AMQP, OPC UA, MQTT, REST API) that have found their way up and are considered the enablers of IIoT and Industry 4.0. Get your free download now!

AS-Interface Product Range

Get to know our full range of AS-Interface products.