Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Download the complete datasheet as a PDF:
General specifications | ||
---|---|---|
Signal type | Analog input/analog output | |
Functional safety related parameters | ||
Safety Integrity Level (SIL) | SIL 2 | |
Supply | ||
Rated voltage | loop powered | |
Power dissipation | 0.2 W | |
Control circuit | ||
Connection | terminals 8-, 9+ | |
Voltage | max. 30 V DC | |
Current | 4 ... 20 mA (quiescent current < 0.5 mA) | |
Power dissipation | 150 mW at 20 mA and Uin < 24 V | |
Field circuit | ||
Connection | terminals 1+, 2 / 3- | |
Voltage | ≥ 16 V for supply voltage > 21 V | |
Current | 4 ... 20 mA (linear transmission 1 ... 22 mA) | |
Load | ≤ 800 Ω (at 20 mA) | |
Transfer characteristics | ||
Voltage drop | see note | |
Influence of ambient temperature | < 0.5 µA/K | |
Damping | approx. 3 dB | |
Rise time | ≤ 20 µs at 0 Ω, ≤ 600 µs with 800 Ω load | |
Indicators/settings | ||
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Electromagnetic compatibility | NE 21:2007 | |
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Mass | approx. 120 g | |
Dimensions | 20 x 124 x 115 mm (0.8 x 4.9 x 4.5 inch) , housing type B2 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | PTB 02 ATEX 2064 | |
Marking | ![]() |
|
Certificate | PF 11 CERT 0902 X | |
Marking | ![]() |
|
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 | |
International approvals | ||
FM approval | device with FM approval on request |
Manuals | Language | File Type | File Size |
---|---|---|---|
Manual | ENG | 3524 KB | |
Handbuch | GER | 3557 KB | |
Instruction manuals | |||
Инструкции | BUL | 135 KB | |
Návod k poużití | CZE | 131 KB | |
Instruktions manual | DAN | 129 KB | |
Instruction manual | ENG | 135 KB | |
Kasutusjuhend | EST | 126 KB | |
Käyttöohje | FIN | 125 KB | |
Manuel d'instructions | FRA | 130 KB | |
Betriebsanleitung | GER | 135 KB | |
Οδηγίες χρήσης | GRE | 138 KB | |
Handleiding | HOL | 129 KB | |
Instruction manual / Betriebsanleitung | HRV | 129 KB | |
Használati útmutató | HUN | 131 KB | |
Manuale di istruzioni | ITA | 129 KB | |
Lietošanas pamācība | LAV | 129 KB | |
Instrukciju vadovas | LIT | 130 KB | |
Instrukcja obsługi | POL | 131 KB | |
Manual de instruções | POR | 130 KB | |
Manual de utilizare | RON | 130 KB | |
Návod na poużitie | SLK | 130 KB | |
Navodila za uporabo | SLV | 128 KB | |
Manual de instrucciones | SPA | 130 KB | |
Manual | SWE | 127 KB |
CAD | File Type | File Size | |
---|---|---|---|
CAD Portal / CAD Portal | LINK | --- | |
Dimension drawing 2-D (DXF) / Abmessungszeichnung 2-D (DXF) | ZIP | 507 KB | |
Dimension drawing 3-D in IGS format / Abmessungszeichnung 3-D im IGS-Format | IGS | 209 KB | |
Dimension drawing 3-D in STP format / Abmessungszeichnung 3-D im STP-Format | STP | 179 KB | |
EPLAN | |||
EPLAN Data Portal / EPLAN Data Portal | LINK | --- | |
EPLAN macro EDZ / EPLAN Makro EDZ | EDZ | 47 KB |
Statements of compliance | Certificate No. | File Type | File Size |
---|---|---|---|
EU-Declaration of conformity / EU-Konformitätserklärung | DOC-0025D | 401 KB | |
Certificates | |||
Belarus Pattern Approval | Nr. 11709 | 15640 KB | |
EAC EAC TP TC 020/2011 | TC RU C-DE.MH04.B.00397 | 680 KB | |
Europe PTB ATEX Category (2) G | PTB 02 ATEX 2064 | 6215 KB | |
Europe Pepperl+Fuchs Certificate of Compliance ATEX Category 3 | PF 11 CERT 0902 X | 179 KB | |
Russia Belarus Kazakhstan EAC EAC TP TC 012/2011 | EAEC RU C-DE.EX01.B.00102/19 | 9815 KB | |
Russia VNIIMS Pattern Approval | OC.C.34.004.A No.56757 | 6680 KB | |
South Africa MASC | MASC MS/17-0867 | 3971 KB | |
exida Functional Safety Assessment | P+F 03/07-04-R013 | 284 KB |
This isolated barrier is used for intrinsic safety applications. It is loop powered and isolates a 4 mA ... 20mA signal for transmitters and positioners and is HART compatible.
With a noticeably lower power loss compared to active isolator modules, the barriers 5 V drop makes it suitable for transmitter applications with unstable power sources between 20 V DC ... 30 V DC.
Line fault detection of the field circuit is possible if the control loop in the safe area is monitored for overscale or underscale conditions of the 4 mA ... 20mA range.
The module can also be used for controlling solenoid valves and discrete outputs, such as LEDs. In this case, terminals 8- and 9+ are driven with a 24 V signal.