Serviceline Industrial Sensors
Serviceline Explosion Protection

WIS transmitter primary NDP5-30GM-5M

NDP5-30GM-5M
  • Transfer range up to 5 mm
  • Short version

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH, also apply to Pepperl+Fuchs AG.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  NDP5-30GM-5M

Product Description
Inductive transmitter system
General specifications
Installationnon-flush
Transfer distance0 ... 5 mm
Output type2-wire
Functional safety related parameters
MTTFd31930 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Approvals and certificates
CCC approvalCCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature0 ... 50 °C (32 ... 122 °F)
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Mechanical specifications
Connection typecable PVC , 5 m
Core cross-section0.75 mm2
Housing materialbrass, nickel-plated
Sensing facePBT
Degree of protectionIP67
Cable
Cable diameter6 mm ± 0.2 mm
Bending radius> 10 x cable diameter
Installationscrew mounting
Free zone≥ 3 mm
Spacing to metal walls≥ ∅ 50 mm
Security zone≥ 60 mm x 15 mm
General information
NoteMaximum cable length between WIS module and WIS transmitter must not exceed 5 m.

Documents: NDP5-30GM-5M

BrochuresLanguageFile TypeFile Size
Application report - Non-Contact, Wear-Free Signal and Power TransmissionENGPDF314 KB
Applilkationsbericht - Berührungslose Übertragung ohne Verschleiß GERPDF317 KB
Instruction leaflets
Instruction leaflet / Beipackzettel ALLPDF335 KB

Associated Products: NDP5-30GM-5M

Matching system components
fa
Accessories

Mounting flange, 30 mmfa
Cable protectorfa