Base for read/write station U-P6-B5

U-P6-B5
  • INTERBUS-remote bus subscriber
  • 2 PG screw fittings for IN and OUT supply
    2 EMV PG screw fittings for BUS IN and OUT
  • Complete read/write functionality via the INTERBUS
  • Transfer of 10 bytes of data in one cycle
  • DIP switch for ring termination
  • Field device with degree of protection IP67

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  U-P6-B5

Product Description
Base for INTERBUS
Indicators/operating means
DIP switchring termination
0 = closed
1 = bus continued
Electrical specifications
Rated operating voltage20 ... 30 V DC , ripple 10 %SS , PELV
Power consumptionmax. 5 W with read/write head IPT*-FP
Galvanic isolation
Operating voltage/interfacefunctional insulation acc. to DIN EN 50178, rated insulation voltage 50 Veff
Interface
Physical RS-485
ProtocolINTERBUS remote bus
ID code03
Transfer rate500 kBit/s or 2 MBit/s internally switchable
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Degree of protectionIP67 according to EN 60529 with IPT*-FP
Connectionscrew terminals
Interface cableup to 1.5 mm2
Supplyup to 3 x 1.5 mm2
Material
Housingaluminum, black anodized
Dimensions
Height50 mm
Width80 mm
Length161 mm

Classifications

SystemClasscode
ECLASS 13.027280492
ECLASS 12.027280490
ECLASS 11.027280490
ECLASS 10.0.127280490
ECLASS 9.027280490
ECLASS 8.027280490
ECLASS 5.127279212
ETIM 9.0EC002997
ETIM 8.0EC002997
ETIM 7.0EC002997
ETIM 6.0EC002997
ETIM 5.0EC003015
UNSPSC 12.131162301

Details: U-P6-B5

Function

The base is used in combination with an upper part, the IPT*-FP read/write station.

The device is operated as a slave on the INTERBUS remote bus. The device makes available the complete read/write functionality. Up to 10 bytes are transmitted per cycle.

The continuing bus is activated via DIP switch.

Product Documentation: U-P6-B5

Language Selection:
Brief InstructionsLanguageFile TypeFile Size
Instruction leaflet / BeipackzettelALLPDF318 KB
Manuals
Manual IPTx-FP with U-P6-B5ENGPDF2421 KB

Design / Simulation: U-P6-B5

Language Selection:
CADLanguageFile TypeFile Size
CAD 3-D / CAD 3-DALLSTP469 KB
CAD Portal / CAD PortalALLLINK---

Approvals: U-P6-B5

Language Selection:
Declaration of ConformityCertificate No.LanguageFile TypeFile Size
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-5411ALLPDF108 KB

Associated Products: U-P6-B5

Matching System Components
LF R/W system, fully assembled as configuration and test stationfa
Visit the RFID Hub

Visit our "RFID Hub"—this special website is a knowledge base for RFID. Get answers on frequently asked questions and learn about typical RFID applications …