Serviceline Industrial Sensors
Serviceline Explosion Protection

Control interface unit IC-KP-B6-V15B

IC-KP-B6-V15B
  • Max. 4 read/write heads connectable
  • Alternative 2 read/write heads and 2 trigger sensors can be connected
  • LC display with background lightning
  • Direct operation via 4 keys
  • LED status indicator of bus communication and read/write heads

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  IC-KP-B6-V15B

Product Description
Control interface unit IDENTControl with PROFIBUS DP interface
General specifications
Number of read/write headsmax. 4
alternative 2 read/write heads and 2 trigger sensors
UL File NumberE87056
Indicators/operating means
LEDs 1, 2, 3, 4Status indicator for read/write heads
green: command at read/write head active
yellow: approx. 1 second long, if command was successfully executed
LED PWR/ERRgreen: power on
red: Hardware fault
LED ULgreen: Interface Power ON/OK
LED Bus Errorred: Bus error
LED Data Exchgreen: Slave is at state "Data Exchange"
LED DPV1Yellow: not used
LC displaytwo-line multi-function display with 12 characters per line
configuration of the control interface and display of connected read/write heads as additional pictograms; easy and direct selection of operating commands and addressing
Button4 keys: ESC, up, down and return
Electrical specifications
Rated operating voltage20 ... 30 V DC , PELV
Ripple≤ 10 % at 30 V DC
Current consumption≤ 2 A incl. read/write heads
Power consumption3.5 W Without read/write heads
Galvanic isolationbasic insulation acc. to DIN EN 50178, rated insulation voltage of 50 Veff
Interface
Physical RS-485
ProtocolPROFIBUS DP acc. to EN 50170
Transfer rate9.6; 19.2; 93.75; 187.5; 500; 1500 kBit/s
3; 6; 12 Mbit/s self-synchronizing
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1
RoHS
Directive 2011/65/EU (RoHS)IEC/EN 63000
Standard conformity
Degree of protectionIEC 60529
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-30 ... 80 °C (-22 ... 176 °F)
Climatic conditionsair humidity max. 96 %
Salt spray resistant to EN 60068-2-52
Shock and impact resistanceOscillation (Sine): 5 g, 10 - 1000 Hz to EN 60068-2-6
Shock (Half-sine): 30 g, 11 ms in accordance with EN 60068-2-27
Mechanical specifications
Housing length148 mm
Housing width105 mm
Housing height73 mm
Degree of protectionIP67
ConnectionRead/write heads: shielded, 4-pin, M12 connector
Power supply: M12 connector
Protective earth: M6 earthing screw
PROFIBUS: M12 connector, B-coded
Material
Housingpowder coated aluminum
Installationsnap-on to 35 mm standard rail or screw fixing
Massapprox. 1000 g

Classifications

SystemClasscode
ECLASS 11.027280401
ECLASS 10.0.127280401
ECLASS 9.027280401
ECLASS 8.027280401
ECLASS 5.127280401
ETIM 8.0EC002998
ETIM 7.0EC002998
ETIM 6.0EC002998
ETIM 5.0EC002998
UNSPSC 12.143211710

Documents: IC-KP-B6-V15B

ManualsLanguageFile TypeFile Size
Manual Communication IRI/IVI modeENGPDF2721 KB
Manual IC-KP-B6-V15BENGPDF3394 KB
Manual Read / Write Ranges and Passing Speeds RFIDENGPDF3640 KB
Handbuch IC-KP-B6-V15BGERPDF3392 KB
Handbuch Kommunikation IRI/IVI-ModusGERPDF506 KB
Handbuch Schreib- und Leseabstände und Vorbeifahrgeschwindigkeiten RFIDGERPDF3642 KB
Instruction leaflets
Device mounting / GerätemontageALLPDF917 KB
Short instructions, safety information
Quick Start Guide IC-KP-*ENGPDF1019 KB
Kurzanleitung IC-KP-*GERPDF1014 KB
Application reports
Application Report - RFID Systems in Industrial Metal StampingENGPDF1773 KB
Applikationsbericht - RFID-Systeme beim industriellen MetallstanzenGERPDF716 KB

CAD+CAE: IC-KP-B6-V15B

CADFile TypeFile Size
3-D model / 3-D-ModellSTP7111 KB
CAD Portal / CAD PortalLINK---

Approvals+Certificates: IC-KP-B6-V15B

CertificatesCertificate No.File TypeFile Size
Australia Declaration of ConformityACMA Supplier's declaration of conformityPDF734 KB
Canada, USA ULCoC UL-CA-L87056-31-61115002-0 / UL-US-L87056-11-61115002-0PDF561 KB
Korea Radio ApprovalMSIP-REI-PF1-ICKPB6V15BPDF362 KB
Declaration of Conformity
EU-Declaration of conformity / EU-KonformitätserklärungDOC-1845CPDF108 KB
UK-Declaration of conformity / UK-KonformitätserklärungDOC-7045PDF107 KB

Commissioning: IC-KP-B6-V15B

Commissioning examplesLanguageFile TypeFile Size
Commissioning IC-KP-B6 with PROFIBUS at S7-400ENGPDF929 KB
Inbetriebnahme IC-KP-B6 mit PROFIBUS an S7-400GERPDF494 KB
Commissioning files
Function block Step 7 Classic for the evaluation unit IC-KP-Bxx (Profinet + Profibus) with the RFID heads IPH-...-V1 for complete reading and writing of the IPC03 data carrier / Funktionsbaustein Step 7 Classic für die Auswerteeinheit IC-KP-Bxx (Profinet + Profibus) mit den RFID-Köpfen IPH-...-V1 zum vollständigen Lesen und Schreiben des IPC03 DatenträgersALLZIP2184 KB
Function block Step 7 Classic for the evaluation unit IC-KP-Bxx (Profinet + Profibus) with the RFID heads IQH1-...-V1 for complete reading and writing of the IQC21 data carrier / Funktionsbaustein Step 7 Classic für die Auswerteeinheit IC-KP-Bxx (Profinet + Profibus) mit den RFID-Köpfen IQH1-...-V1 zum vollständigen Lesen und Schreiben des IQC21 DatenträgersALLZIP2180 KB
Function block Step 7 Classic for the evaluation unit IC-KP-Bxx (Profinet + Profibus) with the RFID heads IQH1-...-V1 for complete reading and writing of the IQC22 data carrier / Funktionsbaustein Step 7 Classic für die Auswerteeinheit IC-KP-Bxx (Profinet + Profibus) mit den RFID-Köpfen IQH1-...-V1 zum vollständigen Lesen und Schreiben des IQC22 DatenträgersALLZIP2181 KB
Function block Step 7 Classic for the evaluation unit IC-KP-Bxx (Profinet + Profibus) with the RFID heads IQH1-...-V1 for complete reading and writing of the IQC24 data carrier / Funktionsbaustein Step 7 Classic für die Auswerteeinheit IC-KP-Bxx (Profinet + Profibus) mit den RFID-Köpfen IQH1-...-V1 zum vollständigen Lesen und Schreiben des IQC24 DatenträgersALLZIP2182 KB
Function block Step 7 Classic for the evaluation unit IC-KP-Bxx (Profinet + Profibus) with the RFID heads IQH1-...-V1 for complete reading and writing of the IQC33 data carrier / Funktionsbaustein Step 7 Classic für die Auswerteeinheit IC-KP-Bxx (Profinet + Profibus) mit den RFID-Köpfen IQH1-...-V1 zum vollständigen Lesen und Schreiben des IQC33 DatenträgersALLZIP2176 KB
Function block Step 7 Classic for the evaluation unit IC-KP-Bxx (Profinet + Profibus) with the RFID heads IQH1-...-V1 for complete reading and writing of the IQC35 data carrier / Funktionsbaustein Step 7 Classic für die Auswerteeinheit IC-KP-Bxx (Profinet + Profibus) mit den RFID-Köpfen IQH1-...-V1 zum vollständigen Lesen und Schreiben des IQC35 DatenträgersALLZIP2180 KB
Function block TIA Portal (S7-1200/1500) for the evaluation units IDENTControl IC-KP-Bxx (Profinet + Profibus) when using IPH-...-V1, IQH1-...-V1 or IUH-...-V1 RFID heads with single-frame protocol. / Funktionsbaustein TIA Portal (S7-1200/1500) für die Auswerteeinheiten IDENTControl IC-KP-Bxx (Profinet + Profibus) bei der Verwendung von IPH-...-V1, IQH1-...-V1 oder IUH-...-V1 RFID-Köpfen mit Single-Frame Protokoll.ALLZIP12098 KB
Function block TIA Portal (S7-300/400) for the evaluation units IDENTControl IC-KP-B17 (Profinet) und IC-KP-B6 (Profibus) when using IPH-...-V1, IQH1-...-V1 or IUH-...-V1 RFID heads with single-frame protocol. / Funktionsbaustein TIA Portal (S7-300/400) für die Auswerteeinheiten IDENTControl IC-KP-B17 (Profinet) und IC-KP-B6 (Profibus) bei der Verwendung von IPH-...-V1, IQH1-...-V1 oder IUH-...-V1 RFID-Köpfen mit Single-Frame Protokoll.ALLZIP10516 KB
SIMATIC S7 sample project file for PROFIBUS with IC-KP-B6 / SIMATIC S7 Beispielprojekt für PROFIBUS Anbindung mit IC-KP-B6ALLZIP357 KB

Software: IC-KP-B6-V15B

Device DriverRelease InfoFile TypeFile Size
GSD file IC-KP-B6-... / GSD-Datei IC-KP-B6-...11/2005ZIP6 KB

Associated Products: IC-KP-B6-V15B

Accessory of

HF read/write head, ISO 15693, for IDENTControlfa

HF read/write head, ISO 15693, for IDENTControlfa

HF read/write head, ISO 15693, for IDENTControlfa

Read/Write head for IDENTControl, 125 kHz, thread M30 x 1.5fa

Read/Write head for IDENTControl, 125 kHz, thread M18 x 1fa

Read/Write head for IDENTControl, 125 kHz, flat housingfa

Read/Write head for IDENTControl, 125 kHz, square housingfa
HF read/write head, ISO 15693, for IDENTControlfa
HF read/write head, ISO 15693, for IDENTControlfa
HF read/write head, ISO 15693, for IDENTControlfa
Read/Write head for IDENTControl, 125 kHz, square housingfa
LF read/write head for IDENTControlfa
LF read/write head for IDENTControlfa
Read/Write head for IDENTControl, 125 kHzfa
Accessories

Cordset M12 socket straight to M12 plug angled A-coded, 4-pin, PUR cable grey, shieldedfa

Cordset M12 socket straight to M12 plug angled A-coded, 4-pin, PUR cable grey, shieldedfa

Female cordset single-ended M12 straight A-coded, 4-pin, PUR cable greyfa

Cordset M12 socket straight to M12 plug angled A-coded, 4-pin, PUR cable grey, shieldedfa

Female cordset single-ended M12 straight A-coded, 4-pin, PUR cable grey, shieldedfa

Y connection cable for PROFIBUSfa

Terminal cable for PROFIBUS with terminal resistorfa
PROFIBUS bus cable M12 socket straight to M12 plug straight B-coded, 5-pin, PUR cable 2-core violet, shieldedfa

Function: IC-KP-B6-V15B

The innovative concept of the RFID identification system IDENTControl from Pepperl+ Fuchs has many advantages in comparison to other systems. The core piece of the system is the evaluation unit IDENTControl.

Thanks to the integrated interfaces for all standard field bus systems such as PROFIBUS, EtherNet, PROFINET IO, DeviceNet, serial connections (RS 232/RS 485/RS 422) and numerous connection options for inductive write/read heads as well as microwave antennas, the evaluation unit IDENTControl can be adjusted to your needs in a flexible and easy manner.

LEDs indicate operating power and bus communication, connected write/read heads and active write/read commands.

Mounting the unit onto DIN mounting rails is easy thanks to the snap-fits on the back of the housing of the evaluation unit IDENTControl .

With its L-shaped housing, the evaluation unit including bus connector fits into a 120 mm grid in the switch cabinet. The mounting depth of 70 mm furthermore enables installation in flat switch boxes with a depth of only 100 mm.

There are 3 further mounting holes for field mounting.

Visit the RFID Hub

Visit our "RFID Hub"—this special website is a knowledge base for RFID. Get answers on frequently asked questions and learn about typical RFID applications …