General specifications |
Operating frequency | 125 kHz |
Transfer rate | 2 kBit/s |
Sensing range | |
| Read distance | 1 ... 75 mm |
| Write distance | 2 ... 65 mm |
| Width | max. 60 mm |
Operating distance | maximum: 80 mm |
UL File Number | E87056 |
Indicators/operating means |
LED green/yellow | green: power on green flashing: read/write attempt performed yellow: data carrier detected |
Electrical specifications |
Power consumption | ≤ 1.2 W |
Supply | from the IDENTControl |
Compliance with standards and directives |
Directive conformity | |
| R&TTE Directive 1995/5/EC | EN 301489-1 V1.8.1 (2008-04), EN 301489-3 V1.4.1 (2002-08), EN 300330-2 V1.3.1 (2006-04), EN 60950-1:2006 |
Standard conformity | |
| Electromagnetic compatibility | EN 61326 |
| Degree of protection | EN 60529 |
Approvals and certificates |
EAC conformity | TR CU 020/2011 |
Ambient conditions |
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Mechanical specifications |
Degree of protection | IP67 |
Connection | M12 x 1 connector |
Material | |
| Housing | PA-GF35 Zinc die cast |
| Encapsulation compound | Fermadur |
Installation | non-flush in metal |
| Distance between two heads | Multiplex on: ≥ 60 mm Multiplex off: ≥ 450 mm |
Mass | approx. 210 g |