Serviceline Industrial Sensors
Serviceline Explosion Protection

Current Driver KFD2-CD-1.32

KFD2-CD-1.32
  • 1-channel signal conditioner
  • 24 V DC supply (Power Rail)
  • Current input 0 mA ... 20 mA
  • Current output 0 mA ... 20 mA
  • Accuracy 0.1 %
  • Up to SIL 2 acc. to IEC 61508

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH, also apply to Pepperl+Fuchs AG.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  KFD2-CD-1.32

General specifications
Signal typeAnalog output
Functional safety related parameters
Safety Integrity Level (SIL)SIL 2
Supply
ConnectionPower Rail or terminals 7+, 8-
Rated voltage20 ... 35 V DC
Ripplewithin the supply tolerance
Rated current≤ 50 mA
Power dissipation1.2 W
Input
Connection sidecontrol side
Connectionterminals 9+, 10-, 11+
Voltage dropapprox. 4 V at 20 mA
LimitInput current: approx. ≤40 mA ; input voltage: ≤ 35 V
Transmission range0 ... 20 mA
Voltage≤ 4 V at 20 mA
Output
Connection sidefield side
Connectionterminals 1+, 2-
Current0 ... 20 mA
Loadmax. 850 Ω
Voltage17 V at 20 mA
Transfer characteristics
Accuracy0.1 %
Deviation
After calibration≤ ± 0.1 % incl. non-linearity and hysteresis at 20 °C (68 °F)
Influence of ambient temperature≤ ± 0.01 %
Rise time< 10 ms
Galvanic isolation
Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Input/power supplyfunctional insulation, rated insulation voltage 50 V AC
Output/power supplysafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Indicators/settings
Display elementsLED
Labelingspace for labeling at the front
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Conformity
Insulation coordinationEN 50178
Galvanic isolationEN 50178
Degree of protectionIEC 60529
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Mechanical specifications
Degree of protectionIP20
Connectionscrew terminals
Massapprox. 100 g
Dimensions20 x 107 x 115 mm (0.8 x 4.2 x 4.5 inch) , housing type B1
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
Data for application in connection with hazardous areas
CertificateTÜV 99 ATEX 1499 X
MarkingEx-Hexagon II 3G Ex nA II T4
Directive conformity
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-15:2010
General information
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Accessories
Optional accessories- power feed module KFD2-EB2(.R4A.B)(.SP)
- universal power rail UPR-03(-M)(-S)
- profile rail K-DUCT-GY(-UPR-03)

Documents: KFD2-CD-1.32

ManualsLanguageFile TypeFile Size
Manual Signal Conditioners K-SystemENGPDF694 KB
Handbuch Signaltrenner K-SystemGERPDF698 KB
Manual Signal Conditioners K-SystemRUSPDF3736 KB
Instruction manuals
ИнструкцииBULPDF61 KB
Návod k poużitíCZEPDF55 KB
Instruktions manualDANPDF54 KB
Instruction manualENGPDF47 KB
KasutusjuhendESTPDF51 KB
KäyttöohjeFINPDF51 KB
Manuel d'instructionsFRAPDF88 KB
BetriebsanleitungGERPDF50 KB
Οδηγίες χρήσηςGREPDF63 KB
HandleidingHOLPDF64 KB
Instruction manual / BetriebsanleitungHRVPDF64 KB
Használati útmutatóHUNPDF64 KB
Manuale di istruzioniITAPDF85 KB
Lietošanas pamācībaLAVPDF62 KB
Instrukciju vadovasLITPDF62 KB
Instrukcja obsługiPOLPDF65 KB
Manual de instruçõesPORPDF65 KB
Manual de utilizareRONPDF65 KB
Návod na poużitieSLKPDF123 KB
Manual de instruccionesSPAPDF87 KB
ManualSWEPDF61 KB

Approvals+Certificates: KFD2-CD-1.32

Statements of complianceCertificate No.File TypeFile Size
EU-Declaration of conformity / EU-KonformitätserklärungDOC-0050BPDF399 KB
Certificates
Belarus Pattern ApprovalNr. 11709PDF15640 KB
Canada UL cULE106378 cUL (QUZW7)LINK---
Europe TUV Nord ATEX Category 3 GTÜV 99 ATEX 1499XPDF1999 KB
Russia VNIIMS Pattern ApprovalDE.C.34.004.A No.56757PDF6680 KB
USA ULE106378 UL (QUZW)LINK---
exida Functional Safety AssessmentP+F 03/10-12 R014PDF302 KB

Associated Products: KFD2-CD-1.32

Accessories

Interface for Power Rail, Used for redundant configuration, Supply current ≤ 4 A, Replaceable fuse, Relay contact output, reversible, LED status indicationpa

Interface for Power Rail, Supply current ≤ 4 A, Replaceable fuse, Relay contact output, reversible, LED status indicationpa

35 mm DIN mounting rail with 3-conductor insert, Provides DC supply voltage to all equipped K-System modules, Standard length 2 m (6 foot), simple to customize to application space, Eliminates daisy-chainspa

35 mm DIN mounting rail with 3-conductor insert, Provides DC supply voltage to all equipped K-System modules, Standard length 0.8 m (2.6 ft), simple to customize to application space, Eliminates daisy-chainspa
Interface for Power Rail, Used for redundant configuration, Supply current ≤ 4 A, Replaceable fuse, Relay contact output, reversible, LED status indication, Connection via spring terminals with push-in connection technologypa
Interface for Power Rail, Supply current ≤ 4 A, Replaceable fuse, Relay contact output, reversible, LED status indication, Connection via spring terminals with push-in connection technologypa
35 mm DIN mounting rail with 3-conductor insert, Provides DC supply voltage to all equipped K-System modules, Standard length 1.6 m (5 foot), simple to customize to application space, Eliminates daisy-chainspa
Cable trunking is integrated in the mounting profile, Safe spacious separation of field and control signals, No additional cable guides necessary, Standard length 1.8 m (5.8 ft), simple to customize to application space, With mounting aidspa
Cable trunking with integrated Power Rail UPR-03, Safe spacious separation of field and control signals, No additional cable guides necessary, Provides DC supply voltage to all equipped K-System modules, Standard length 1.8 m (5.8 ft), simple to customize to application space, With end caps UPR-E, cover and mounting aidspa