Serviceline Industrial Sensors
Serviceline Explosion Protection

Female cordset, field attachable V15-G-PG9

V15-G-PG9
  • Screw terminal connection
  • Metal locking
  • Knurled nut suitable for tool assembly
  • cURus approval

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  V15-G-PG9

Product Description
Female connector, M12, 5-pin, field attachable
General specifications
Connector 1
Connectionsocket
Construction typeM12
Stylestraight
Lockingscrew connection
Number of pins5
UL File NumberE363587
Electrical specifications
Operating voltagemax. 48 V AC / 60 V DC
Operating currentmax. 4 A
Volume resistance< 8 mΩ
Conformity
Degree of protectionEN 60529
Ambient conditions
Ambient temperature-40 ... 85 °C (-40 ... 185 °F)
Pollution degree3
Mechanical specifications
Plug connector
Tightening torque0.5 Nm
Tool installationstraight knurling , hexagon nut SW = 18 mm
Mating cyclesmin. 50
Degree of protectionIP67
ConnectionScrew terminals for max. 0.75 mm2
PG9 cable gland
Cable
Sheath diameter6 ... 8 mm
Material
Plug connector
Screw connectionZinc diecast, nickel-plated
BodyPA, black
Contact surfaceCuSnZn

Classifications

SystemClasscode
ECLASS 11.027440102
ECLASS 10.0.127440102
ECLASS 9.027440102
ECLASS 8.027440104
ECLASS 5.127279201
ETIM 8.0EC002635
ETIM 7.0EC002635
ETIM 6.0EC002635
ETIM 5.0EC002585

CAD+CAE: V15-G-PG9

CADFile TypeFile Size
3-D model / 3-D-ModellSTP1780 KB
CAD Portal / CAD PortalLINK---
EPLAN
EPLAN Data Portal / EPLAN Data PortalLINK---

Approvals+Certificates: V15-G-PG9

Statements of complianceCertificate No.File TypeFile Size
EU-Declaration of conformity / EU-KonformitätserklärungDOC-4666PDF337 KB
Certificates
US CA ULE363587LINK---

Associated Products: V15-G-PG9

Accessory of

Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 50 m, PROFIBUS, M12 plug, Measuring method PRT (Pulse Ranging Technology), Non-contact precision measurement, Ultra-fast data acquisition, Active dynamic control, Modern lightweight design, extremely robustfa

Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 300 m, PROFIBUS, M12 plug, Measuring method PRT (Pulse Ranging Technology), Non-contact precision measurement, Ultra-fast data acquisition, Active dynamic control, Modern lightweight design, extremely robustfa

Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 150 m, PROFIBUS, M12 plug, Measuring method PRT (Pulse Ranging Technology), Non-contact precision measurement, Ultra-fast data acquisition, Active dynamic control, Modern lightweight design, extremely robustfa

Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 50 m, SSI interface - switchable to RS-422, M12 plug, Measuring method PRT (Pulse Ranging Technology), Active dynamic control, Switchable SSI/RS 422 interface, Non-contact precision measurement, Ultra-fast data acquisitionfa

Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 300 m, SSI interface - switchable to RS-422, M12 plug, Measuring method PRT (Pulse Ranging Technology), Non-contact precision measurement, Switchable SSI/RS 422 interface, Ultra-fast data acquisition, Active dynamic controlfa

Optical data coupler for PROFIBUS, 120 m detection range, infrared light, M12 plug, Devices for PROFIBUS, Problem-free light beam interruption due to TVT (Telegram Verification Technology), Plug connection for fast mounting, Simple programming without opening the device, Usable up to detection range 0fa

Optical data coupler for PROFIBUS, 120 m detection range, infrared light, M12 plug, Devices for PROFIBUS, Problem-free light beam interruption due to TVT (Telegram Verification Technology), Plug connection for fast mounting, Simple programming without opening the device, Usable up to detection range 0fa

Optical data coupler for PROFIBUS, 240 m detection range, infrared light, M12 plug, Devices for PROFIBUS, Problem-free light beam interruption due to TVT (Telegram Verification Technology), Plug connection for fast mounting, Simple programming without opening the device, Usable up to detection range 0fa

Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 150 m, SSI interface - switchable to RS-422, M12 plug, Measuring method PRT (Pulse Ranging Technology), Non-contact precision measurement, Switchable SSI/RS 422 interface, Ultra-fast data acquisition, Active dynamic controlfa

Optical data coupler for PROFIBUS, 240 m detection range, infrared light, M12 plug, Devices for PROFIBUS, Problem-free light beam interruption due to TVT (Telegram Verification Technology), Plug connection for fast mounting, Simple programming without opening the device, Usable up to detection range 0fa
Optical data coupler for INTERBUS, 120 m detection range, infrared light, M12 plug, Devices for INTERBUS, Plug connection for fast mounting, No parameterization, Usable up to detection range 0, Line indicator for signal strengthfa
Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 300 m, PROFIBUS, M12 plug, Measuring method PRT (Pulse Ranging Technology), Non-contact precision measurement, Ultra-fast data acquisition, Active dynamic control, Modern lightweight design, extremely robustfa
Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 300 m, SSI interface - switchable to RS-422, M12 plug, Measuring method PRT (Pulse Ranging Technology), Non-contact precision measurement, Switchable SSI/RS 422 interface, Ultra-fast data acquisition, Active dynamic controlfa
Distance sensor with EtherNet/IP-Interface, Measuring method PRT (Pulse Ranging Technology), Non-contact precision measurement, Ultra-fast data acquisition, Active dynamic control, Modern lightweight design, extremely robustfa
Distance sensor with EtherNet/IP-Interface, Measuring method PRT (Pulse Ranging Technology), Non-contact precision measurement, Ultra-fast data acquisition, Active dynamic control, Modern lightweight design, extremely robustfa
Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 300 m, INTERBUS, M12 plug, Measuring method PRT (Pulse Ranging Technology), Non-contact precision measurement, Ultra-fast data acquisition, Active dynamic control, Modern lightweight design, extremely robustfa
Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 50 m, INTERBUS, M12 plug, Measuring method PRT (Pulse Ranging Technology), Non-contact precision measurement, Ultra-fast data acquisition, Active dynamic control, Modern lightweight design, extremely robustfa
Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 150 m, INTERBUS, M12 plug, Measuring method PRT (Pulse Ranging Technology), Non-contact precision measurement, Ultra-fast data acquisition, Active dynamic control, Modern lightweight design, extremely robustfa
Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 50 m, PROFIBUS, M12 plug, low temperature version, Measuring method PRT (Pulse Ranging Technology), Version for low temperature applications, Non-contact precision measurement, Ultra-fast data acquisition, Active dynamic controlfa
Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 150 m, PROFIBUS, M12 plug, low temperature version, Measuring method PRT (Pulse Ranging Technology), Version for low temperature applications, Non-contact precision measurement, Ultra-fast data acquisition, Active dynamic controlfa
Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 50 m, SSI interface - switchable to RS-422, M12 plug, low-temperature version, Measuring method PRT (Pulse Ranging Technology), Version for low temperature applications, Non-contact precision measurement, Switchable SSI/RS 422 interface, Ultra-fast data acquisitionfa
Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 150 m, SSI interface - switchable to RS-422, M12 plug, low-temperature version, Measuring method PRT (Pulse Ranging Technology), Version for low temperature applications, Non-contact precision measurement, Switchable SSI/RS 422 interface, Ultra-fast data acquisitionfa
Distance sensor with EtherNet/IP-Interface, Measuring method PRT (Pulse Ranging Technology), Non-contact precision measurement, Ultra-fast data acquisition, Active dynamic control, Modern lightweight design, extremely robustfa
Optical data coupler for INTERBUS, 120 m detection range, infrared light, M12 plug, Devices for INTERBUS, Plug connection for fast mounting, No parameterization, Usable up to detection range 0, Line indicator for signal strengthfa
Optical data coupler for INTERBUS, 240 m detection range, infrared light, M12 plug, Devices for INTERBUS, Plug connection for fast mounting, No parameterization, Usable up to detection range 0, Line indicator for signal strengthfa
Optical data coupler for INTERBUS, 240 m detection range, infrared light, M12 plug, Devices for INTERBUS, Plug connection for fast mounting, No parameterization, Usable up to detection range 0, Line indicator for signal strengthfa
Optical data coupler for INTERBUS, 120 m detection range, infrared light, M12 plug, low temperature version, Devices for INTERBUS, Version for low temperature applications, Plug connection for fast mounting, No parameterization, Usable up to detection range 0fa
Optical data coupler for INTERBUS, 120 m detection range, infrared light, M12 plug, low temperature version, Devices for INTERBUS, Version for low temperature applications, Plug connection for fast mounting, No parameterization, Usable up to detection range 0fa
Optical data coupler for PROFIBUS, 120 m detection range, infrared light, M12 plug, low temperature version, Devices for PROFIBUS, Version for low temperature applications, Problem-free light beam interruption due to TVT (Telegram Verification Technology), Plug connection for fast mounting, Simple programming without opening the devicefa
Optical data coupler for PROFIBUS, 120 m detection range, infrared light, M12 plug, low temperature version, Devices for PROFIBUS, Version for low temperature applications, Problem-free light beam interruption due to TVT (Telegram Verification Technology), Plug connection for fast mounting, Simple programming without opening the devicefa
Optical data coupler for INTERBUS, 240 m detection range, infrared light, M12 plug, low temperature version, Devices for INTERBUS, Version for low temperature applications, Plug connection for fast mounting, No parameterization, Usable up to detection range 0fa
Optical data coupler for INTERBUS, 240 m detection range, infrared light, M12 plug, low temperature version, Devices for INTERBUS, Version for low temperature applications, Plug connection for fast mounting, No parameterization, Usable up to detection range 0fa
Optical data coupler for PROFIBUS, 150 m detection range, infrared light, M12 plug, Devices for PROFIBUS, Identical units communicate with each other, Problem-free light beam interruption due to TVT (Telegram Verification Technology), Plug connection for fast mounting, Simple programming without opening the devicefa
Industrial standard housing ∅58 mm, Ethernet interface with Powerlink, 30 Bit multiturn, Two Ethernet connectors with built in hub, Recessed hollow shaft, Protocol: Powerlink standard protocolfa
Industrial standard housing ∅58 mm, Ethernet interface with Powerlink, 16 Bit singleturn, Two Ethernet connectors with built in hub, Recessed hollow shaft, Protocol: Powerlink standard protocolfa
Industrial standard housing ∅58 mm, Ethernet interface with Powerlink, 30 Bit multiturn, Two Ethernet connectors with built in hub, Servo or clamping flange, Protocol: Powerlink standard protocolfa
Industrial standard housing ∅58 mm, Ethernet interface with Powerlink, 16 Bit singleturn, Two Ethernet connectors with built in hub, Servo or clamping flange, Protocol: Powerlink standard protocolfa
Industrial standard housing ∅58 mm, Ethernet interface with TCP/IP, 30 Bit multiturn, Integrated webserver, Recessed hollow shaftfa
Industrial standard housing ∅58 mm, Ethernet interface with TCP/IP, 16 Bit singleturn, Integrated webserver, Recessed hollow shaftfa
Industrial standard housing ∅58 mm, Ethernet interface with TCP/IP, 30 Bit multiturn, Integrated webserver, Servo or clamping flangefa
Industrial standard housing ∅58 mm, Ethernet interface with TCP/IP, 16 Bit singleturn, Integrated webserver, Servo or clamping flangefa
Small fire protection photoelectric sensor for safety devices on fire barriers, Approval in accordance with VdS Test Report FSA and externally monitored manufacture (Ü Symbol), High protection against contact, Not sensitive to ambient light, even with switched energy saving lamps, Effective detection range: 0 ... 2.1 m (with H60 reflector), Light source: LED 645 nm, Light type: modulated visible red light, Operating voltage: 10 ... 30 V DCfa
Single head system, IO-Link interface for parameterization, Programmable via DTM with PACTWARE, Selectable sound lobe width, Series: -F77, Operating voltage: 18 ... 30 V DC , ripple 10 %SS
, Output type: 1 analog output 0 (4) ... 20 mA or
1 analog output 0 ... 10 V, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: cable PUR , 2 m, Housing: Polycarbonatefa
Single head system, IO-Link interface for parameterization, Programmable via DTM with PACTWARE, Selectable sound lobe width, Series: -F77, Operating voltage: 18 ... 30 V DC , ripple 10 %SS
, Output type: 1 analog output 0 (4) ... 20 mA or
1 analog output 0 ... 10 V, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: cable PUR , 5 m, Housing: Polycarbonatefa
Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 50 m, SSI interface, M12 plug, Maximum measurement accuracy, Red laser as the light emitter, Display and keypad for parameter settings, Compact and space-saving design, Measuring method PRT (Pulse Ranging Technology)fa
Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 150 m, SSI interface, M12 plug, Version for low temperature applications, Maximum measurement accuracy, Red laser as the light emitter, Display and keypad for parameter settings, Compact and space-saving designfa
Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 150 m, SSI interface, M12 plug, Maximum measurement accuracy, Red laser as the light emitter, Display and keypad for parameter settings, Compact and space-saving design, Measuring method PRT (Pulse Ranging Technology)fa
Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 50 m, SSI interface, M12 plug, Version for low temperature applications, Maximum measurement accuracy, Red laser as the light emitter, Display and keypad for parameter settings, Compact and space-saving designfa
Cable, PVC/PVC, 5-core greyfa