Datasheet excerpt: Technical data of  V15B-G-15M-LIHCH-TP

Product Description
SSI bus cable, B-coded M12, 5-pin cable
General specifications
Number of pins5 + shield
Connection 1socket
Construction type 1straight
Threading 1M12
Connection 2cable end
Electrical specifications
Operating voltagemax. 48 V AC / 60 V DC
Operating currentmax. 4 A
Volume resistance< 3 mΩ
Compliance with standards and directives
Standard conformity
Specificationconnector M12 x 1 : IEC 61076-2-101
Ambient conditions
Ambient temperaturecable, flexing: -5 ... 70 °C (23 ... 158 °F)
cable, fixed: -30 ... 80 °C (-22 ... 176 °F)
Pollution degree3
Mechanical specifications
Degree of protectionIP67
Connection5-pin, M12 x 1 socket, B-coded
Material
ContactsCuSn
Contact surfaceAu
BodyZinc die-casting, nickel-plated
CablePolymer compound
Slotted nutZinc die-casting, nickel-plated
Cable3 pairs with 2 twisted cores each
Sheath diameter∅ 7.3 mm
Bending radius> 6 x cable diameter, fixed
> 15 x cable diameter, moving
Colorgrey
Cores3 x 2 x 0.25 mm2
Conductor construction14 x 0.15 mm ∅
Shieldgrid covering 85 %
Length15 m

Classifications

SystemClasscode
ECLASS 11.027060311
ECLASS 10.0.127060311
ECLASS 9.027060311
ECLASS 8.027279218
ECLASS 5.127279201
ETIM 8.0EC001855
ETIM 7.0EC001855
ETIM 6.0EC001855
ETIM 5.0EC002585

Approvals+Certificates: V15B-G-15M-LIHCH-TP

Statements of complianceCertificate No.File TypeFile Size
EU-Declaration of conformity / EU-KonformitätserklärungDOC-3302APDF286 KB

Associated Products: V15B-G-15M-LIHCH-TP

Accessory of

Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 50 m, SSI interface - switchable to RS-422, M12 plug, Measuring method PRT (Pulse Ranging Technology), Active dynamic control, Switchable SSI/RS 422 interface, Non-contact precision measurement, Ultra-fast data acquisitionfa

Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 300 m, SSI interface - switchable to RS-422, M12 plug, Measuring method PRT (Pulse Ranging Technology), Non-contact precision measurement, Switchable SSI/RS 422 interface, Ultra-fast data acquisition, Active dynamic controlfa

Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 150 m, SSI interface - switchable to RS-422, M12 plug, Measuring method PRT (Pulse Ranging Technology), Non-contact precision measurement, Switchable SSI/RS 422 interface, Ultra-fast data acquisition, Active dynamic controlfa
Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 50 m, SSI interface - switchable to RS-422, M12 plug, low-temperature version, Measuring method PRT (Pulse Ranging Technology), Version for low temperature applications, Non-contact precision measurement, Switchable SSI/RS 422 interface, Ultra-fast data acquisitionfa
Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 50 m, SSI interface, M12 plug, Maximum measurement accuracy, Red laser as the light emitter, Display and keypad for parameter settings, Compact and space-saving design, Measuring method PRT (Pulse Ranging Technology)fa
Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 150 m, SSI interface, M12 plug, Version for low temperature applications, Maximum measurement accuracy, Red laser as the light emitter, Display and keypad for parameter settings, Compact and space-saving designfa
Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 300 m, SSI interface - switchable to RS-422, M12 plug, Measuring method PRT (Pulse Ranging Technology), Non-contact precision measurement, Switchable SSI/RS 422 interface, Ultra-fast data acquisition, Active dynamic controlfa
Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 50 m, SSI interface, M12 plug, Version for low temperature applications, Maximum measurement accuracy, Red laser as the light emitter, Display and keypad for parameter settings, Compact and space-saving designfa
Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 150 m, SSI interface, M12 plug, Maximum measurement accuracy, Red laser as the light emitter, Display and keypad for parameter settings, Compact and space-saving design, Measuring method PRT (Pulse Ranging Technology)fa
Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 150 m, SSI interface - switchable to RS-422, M12 plug, low-temperature version, Measuring method PRT (Pulse Ranging Technology), Version for low temperature applications, Non-contact precision measurement, Switchable SSI/RS 422 interface, Ultra-fast data acquisitionfa