Serviceline Industrial Sensors
Serviceline Explosion Protection

Temperature Multi-Input Device for Cabinet Installation RD0-TI-Ex8.PA.*

RD0-TI-Ex8.PA.*
  • For 8 temperature or analog sensors
  • Installation in Zone 1/Div. 1, intrinsically safe
  • Sensors in Zone 0/Div. 1
  • Connection to fieldbus acc. to FISCO or Entity
  • For PROFIBUS PA
  • DCS integration via GSD and FDT/DTM
  • Monitors sensor condition
  • For T/C, RTD 2-, 3-, 4-wire, voltage and resistance
  • Cold junction compensation
  • Removable terminals

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  RD0-TI-Ex8.PA.*

General specifications
Design / MountingCabinet installation
Fieldbus connection
Fieldbus typePROFIBUS PA
Firmware updatevia separate plug connection
FDE (Fault Disconnect Equipment)6.7 mA
Polaritynot polarity sensitive
Rated voltage9 ... 32 V
Rated currentmax. 23 mA
PROFIBUS PA
Profile3.02
Indicators/operating means
LED PWRgreen: on, bus voltage existent
LED COM ERRred, continuous lightning: hardware error; red, flashing: no bus activities or bus fault; off: no error
LED CHANNEL ERRORred: 2 Hz flashing: lead breakage, overrange; off: no error
Input
Number8
Sensor typessee table 1
Groundinggrounding of thermoelements possible
Error detectionlead breakage, wiring error, hardware device error
Common mode voltageInput to Input 600 Vpeak
Transfer characteristics
Deviation
Cold junction compensation± 0.5 °C (32.9 °F)
Resolution/accuracysee table 2
Influence of ambient temperaturesee table 3
LinearizationT/C input 0.1°C RTD input 0.03°C
Internal measurement cyclefor all sensor types max. 1 s
Galvanic isolation
Fieldbus/inputssafe galvanic isolation acc. to EN 60079-11, voltage peak value 375 V
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013
Standard conformity
Galvanic isolationEN 60079-11
Electromagnetic compatibilityNE 21:2011
Degree of protectionIEC 60529
Fieldbus standardIEC 61158-2
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6
Ambient conditions
Ambient temperature-40 ... 70 °C (-40 ... 158 °F) hazardous area
-40 ... 85 °C (-40 ... 185 °F) safe area
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity≤ 95 % non-condensing
Shock resistance15 g , 11 ms
Vibration resistance5 g , 10 ... 150 Hz
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
Mechanical specifications
Connection typeplug-in terminals , spring terminal and screw terminal
Core cross-section
Busup to 2.5 mm2
Inputsup to 2.5 mm2
Housing materialPolycarbonate
Degree of protectionIP20
Mass360 g
Mountingmounting on DIN rail in cabinet
Data for application in connection with hazardous areas
EU-type examination certificatePTB 03 ATEX 2237
MarkingEx-Hexagon II 2 (1) G Ex ia [ia Ga] IIC T4 Gb , Ex-Hexagon II (1) G [Ex ia Ga] IIC , Ex-Hexagon II (1) D [Ex ia Da] IIIC , Ex-Hexagon II 3 G Ex ic IIC T4 Gc
BusFISCO see EC-Type Examination Certificate
Voltage Ui24 V
Inputssee EC-Type Examination Certificate
CertificatePTB 03 ATEX 2238 X
MarkingEx-Hexagon II 3 G Ex nA IIC T4 Gc
Galvanic isolation
Bussee Statement of Conformity
Inputsee EC-Type Examination Certificate
Directive conformity
Directive 2014/34/EUEN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010
International approvals
FM approvalCoC 3025732
CSA approvalCoC 3025732C
IECEx approvalIECEx PTB 05.0001 , IECEx PTB 05.0002X
Approved forEx ia [ia Ga] IIC T4 Gb , [Ex ia Ga] IIC , [Ex ia Da] IIIC , Ex ic IIC T4 Gc , Ex nA IIC T4 Gc
Certificates and approvals
Marine approvalDNV A-14038
General information
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

Classifications

SystemClasscode
ECLASS 11.027242610
ECLASS 10.0.127242610
ECLASS 9.027242610
ECLASS 8.027242610
ECLASS 5.127242610
ETIM 8.0EC001601
ETIM 7.0EC001601
ETIM 6.0EC001601
ETIM 5.0EC001604
UNSPSC 12.139121008

Documents: RD0-TI-Ex8.PA.*

ManualsLanguageFile TypeFile Size
ManualENGPDF4255 KB
Instruction manuals
ИнструкцииBULPDF204 KB
Návod k poużitíCZEPDF199 KB
Instruktions manualDANPDF0 KB
Instruction manualENGPDF73 KB
KasutusjuhendESTPDF0 KB
KäyttöohjeFINPDF193 KB
Manuel d'instructionsFRAPDF137 KB
BetriebsanleitungGERPDF76 KB
Οδηγίες χρήσηςGREPDF0 KB
HandleidingHOLPDF0 KB
Instruction manual / BetriebsanleitungHRVPDF197 KB
Használati útmutatóHUNPDF199 KB
Manuale di istruzioniITAPDF134 KB
Lietošanas pamācībaLAVPDF197 KB
Instrukciju vadovasLITPDF199 KB
Instrukcja obsługiPOLPDF200 KB
Manual de instruçõesPORPDF0 KB
Manual de utilizareRONPDF0 KB
Návod na poużitieSLKPDF199 KB
Navodila za uporaboSLVPDF0 KB
Manual de instruccionesSPAPDF134 KB
ManualSWEPDF196 KB
Short instructions, safety information
Release information Device Description (EDDL) for Siemens SIMATIC PDMENGPDF403 KB

CAD+CAE: RD0-TI-Ex8.PA.*

CADFile TypeFile Size
3-D model / 3-D-ModellSTP8801 KB

Approvals+Certificates: RD0-TI-Ex8.PA.*

Statements of complianceCertificate No.File TypeFile Size
EU Declaration of Conformity / EU-KonformitätserklärungDOC-0148FPDF2042 KB
Certificates
Canada FMCoC 3025732CPDF316 KB
DNV GL MarineTAA0000272PDF78 KB
Europe PTB ATEX Category 2 (1)PTB 03 ATEX 2237PDF884 KB
Europe PTB ATEX Category 3 GPTB 03 ATEX 2238XPDF617 KB
India PESO (India) CCOEA/P/HQ/KA/104/5828 (P489740)PDF79 KB
PTB IECEx Certificate of ConformityIECEx PTB 05.0001LINK---
PTB IECEx Certificate of ConformityIECEx PTB 05.0002XLINK---
Russia Belarus Kazakhstan EAC EAC TP TC 020/2011 EMCEAEC N RU D-DE.EA11.B.00318PDF2892 KB
South Africa MASCMASC S/18-2698PDF484 KB
USA FMCoC 3025732PDF316 KB

Software: RD0-TI-Ex8.PA.*

DriversRelease InfoFile TypeFile Size
Device Description (EDDL) for Siemens SIMATIC PDM / Gerätebeschreibung (EDDL) für Siemens SIMATIC PDM1.0.0.585ZIP473 KB
GSD file / GSD-DateiRev. 1.0ZIP6 KB
Device type managers
DTM Collection FieldConnex / DTM-Kollektion FieldConnex1.8.0.2200ZIP35320 KB

Associated Products: RD0-TI-Ex8.PA.*

Matching System Components
For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PA, IECEx approval, Dust protection, Europe, USA, Canada, Device coupler location: non-explosion hazardous area
Zone 2 - high-power trunk
Zone 1 - high-power trunk
Division 2 - high-power trunk
Division 1 - high-power trunk, Device coupler location [2]: Zone 2 - high-power trunkpa
8 channel universal temperature interface, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For PROFIBUS PA, Device coupler location: non-explosion hazardous area
Zone 2 - high-power trunk
Zone 1 - high-power trunk
Zone 1/2 - intrinsically safe high-power trunk
Zone 1 - intrinsically safe trunk, Device coupler location [2]: Zone 2 - high-power trunkpa
8 channel universal temperature interface, Stainless steel, electropolished, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For PROFIBUS PA, Device coupler location: non-explosion hazardous area
Zone 2 - high-power trunk
Zone 1 - high-power trunk
Zone 1/2 - intrinsically safe high-power trunk
Zone 1 - intrinsically safe trunk, Device coupler location [2]: Zone 2 - high-power trunk, Device coupler location [3]: Zone 1 - high-power trunkpa
Accessories
User interface for PROFIBUS components, Simple access to measurements, diagnostic and configuration data, Supports any FDT/DTM hostpa
Software for connecting people, information, systems, and devices, For applications developed using .NET, Required to run PACTwarepa
Universal DTM host platform, For all DTMs of Pepperl+Fuchs, Approved FDT/DTM technology, Free of charge, Download from Pepperl+Fuchs websitepa
Universal DTM host platform, For all DTMs of Pepperl+Fuchs, Approved FDT/DTM technology, Free of charge, Internet download possiblepa

Function: RD0-TI-Ex8.PA.*

The Temperature Multi-Input (TM-I) for DIN rail installation connects up to 8 analog inputs to the DCS via fieldbus. It is installed in a typically pre-wired field enclosure close to the sensors in the hazardous area. The TM-I is certified intrinsically safe and as associated apparatus: inputs are intrinsically safe even when the fieldbus connection is not. Analog inputs can be resistance temperature sensors with 2, 3, and 4 wires, measuring sensors, thermocouples, or millivolt signals.

The TM-I communicates all data, configuration, and alarms via one fieldbus address to the DCS. DCS integration utilizes GSD and FDT/DTM technology. Inputs can be configured all at once or individually. Fieldbus powers the sensors and the temperature interface itself. Additional power or wiring is not required.

Cold junction compensation for thermocouples is integrated. The TM-I detects and reports lead breakage and short circuit conditions.

Ethernet-APL enables continuous communication across all hierarchy levels. Learn more about the pioneering technology …

From decisions to planning, installation, and commissioning up to operation and maintenance: Discover how to make the most out of your fieldbus infrastructure …

The Quick Select Product Guide for interface technology, FieldConnex®, and remote I/O connection technologies will help you select the right technology and systems when designing plants.