Serviceline
Serviceline Industrial Sensors
Serviceline Explosion Protection

Inductive positioning system PMI104-F90-IU-V1

PMI104-F90-IU-V1
  • Analog output 0 V ... 10 V/4 mA ... 20 mA
  • Measuring range 0 ... 104 mm

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of PMI104-F90-IU-V1

General specifications
Switching element functionanalog, current or voltage output
Object distance0.5 ... 3 mm , recommended: 2 mm
Measurement range0 ... 104 mm
Linearity range1 ... 103 mm
Nominal ratings
Operating voltage18 ... 30 V DC
Reverse polarity protectionreverse polarity protected
Linearity errorwithin measuring range: ± 0.8 mm
within linearity range: ± 0.4 mm
Repeat accuracy± 0.1 mm
Resolution125 µm
Temperature drift± 0.5 mm (-25 °C ... 70 °C)
No-load supply current≤ 40 mA
Operating voltage indicatorLED green
Functional safety related parameters
MTTFd320 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Analog output
Output type1 current output: 4 ... 20 mA
1 voltage output: 0 ... 10 V
Load resistorcurrent output: ≤ 400 Ω
voltage output: ≥ 1000 Ω
Short-circuit protectionvoltage output: pulsing
Compliance with standards and directives
Standard conformity
StandardsEN 60947-5-2:2007
IEC 60947-5-2:2007
EN 60947-5-7:2003
IEC 60947-5-7:2003
Approvals and certificates
EAC conformityTR CU 020/2011
UL approvalcULus Listed, General Purpose, Class 2 Power Source
CCC approvalCCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection type4-pin, M12 x 1 connector
Degree of protectionIP67
Material
HousingABS
Targetmild steel, e. g. 1.0037, SR235JR (formerly St37-2)

Documents: PMI104-F90-IU-V1

Instruction leafletsLanguageFile TypeFile Size
Instruction leaflet / Beipackzettel ALLPDF169 KB
Instructions, short instructions, safety information
Linear positioning system F90, instruction manualENGPDF429 KB
Lineares Wegmessystem F90, BetriebsanleitungGERPDF396 KB
Technical information
Installation and Design Notes for Position Sensors, F90 SeriesENGPDF311 KB
Montage- und Konstruktionshinweise für Positionssensoren, Serie F90GERPDF320 KB

Approvals+Certificates: PMI104-F90-IU-V1

Statements of complianceCertificate No.File TypeFile Size
EU-Declaration of conformity / EU-KonformitätserklärungDOC-3053APDF170 KB
Certificates
US CA UL General PurposeE87056LINK---

Associated Products: PMI104-F90-IU-V1

Accessories

Female cordset, M12, 4-pin, PVC cablefa
Damping element for sensors of type F90, F112, and F166; side holefa
Mounting bracket for mounting of F90 sensorsfa
Damping element for sensors of type F90, F112, and F166; front holefa