Serviceline
Serviceline Industrial Sensors
Serviceline Explosion Protection

Inductive positioning system PMI120-F90-IE8-V15

PMI120-F90-IE8-V15
  • Analog output 4 mA ... 20 mA
  • Adjustable switch points
  • Measuring range 0 ... 120 mm

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of PMI120-F90-IE8-V15

General specifications
Switching element functionAnalog current output with PNP binary NO
Object distance0.5 ... 3 mm , recommended: 2 mm
Measurement range0 ... 120 mm
Linearity range1 ... 119 mm
Nominal ratings
Operating voltage18 ... 30 V DC
Reverse polarity protectionreverse polarity protected
Linearity errorwithin measuring range: ± 0.8 mm
within linearity range: ± 0.4 mm
Repeat accuracy± 0.1 mm
Resolution125 µm
Temperature drift± 0.5 mm (-25 °C ... 70 °C)
No-load supply current≤ 40 mA
Operating voltage indicatorLED green
Functional safety related parameters
MTTFd270 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Switching output
Output type2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected
Operating current≤ 100 mA
Switching window± 1 mm
Switching hysteresis0.4 mm
Voltage drop≤ 3 V
Short-circuit protectionpulsing
Analog output
Output type1 current output: 4 ... 20 mA
Load resistor≤ 400 Ω
Compliance with standards and directives
Standard conformity
StandardsEN 60947-5-2:2007
IEC 60947-5-2:2007
Approvals and certificates
UL approvalcULus Listed, General Purpose, Class 2 Power Source
CCC approvalCCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection type5-pin, M12 x 1 connector
Degree of protectionIP67
Material
HousingABS
Targetmild steel, e. g. 1.0037, SR235JR (formerly St37-2)

Documents: PMI120-F90-IE8-V15

Instruction leafletsLanguageFile TypeFile Size
Instruction leaflet / Beipackzettel ALLPDF175 KB
Instructions, short instructions, safety information
Linear positioning system F90, instruction manualENGPDF429 KB
Lineares Wegmessystem F90, BetriebsanleitungGERPDF396 KB
Technical information
Installation and Design Notes for Position Sensors, F90 SeriesENGPDF311 KB
Montage- und Konstruktionshinweise für Positionssensoren, Serie F90GERPDF320 KB

CAD+CAE: PMI120-F90-IE8-V15

CADFile TypeFile Size
3-D model in IGS format / 3-D-Modell im IGS-FormatIGS2915 KB
3-D model in STP format / 3-D-Modell im STP-FormatSTP688 KB
CAD Portal / CAD PortalLINK---

Approvals+Certificates: PMI120-F90-IE8-V15

Statements of complianceCertificate No.File TypeFile Size
EU-Declaration of conformity / EU-KonformitätserklärungDOC-3053APDF170 KB
Certificates
US CA UL General PurposeE87056LINK---

Associated Products: PMI120-F90-IE8-V15

Accessories

Female cordset, M12, 5-pin, PVC cablefa

Female cordset, M12, 5-pin, PVC cablefa
Damping element for sensors of type F90, F112, and F166; side holefa
Mounting bracket for mounting of F90 sensorsfa