Redundancy Base Backplane LB9029A

LB9029A
  • Max. 12 slots for I/O modules
  • Redundancy (field bus and power supply)
  • For PROFIBUS DP, PROFIBUS DP V1 and MODBUS RTU
  • Not extendable
  • Backplane for LB-System
  • Mounting in Zone 2, Class I/Div.2 or in the safe area

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of LB9029A

General specifications
Suitable componentsbackplane LB9024S , LB8105* , LB8106* , LB8108* , LB8109* , LB8107*
Slots
Bus coupler2
Supply3
I/O modules (single width)max. 12
I/O modules (dual width)max. 6
Supply
Maximum safe voltage Um60 V DC (SELV/PELV)
Input voltage range18 ... 32 V DC (SELV/PELV)
Fieldbus interface
Fieldbus typePROFIBUS DP/DP-V1 or MODBUS RTU , depends on bus coupler
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2006
Conformity
Electromagnetic compatibilityNE 21
Degree of protectionEN 60529
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F) , 70 °C (non-Ex)
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Vibration resistancefrequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles
frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Mechanical specifications
Degree of protectionIP20
Massapprox. 1380 g
Dimensions(W x H x D)
440 x 127 x 80 mm (17.3 x 5 x 3.15 inch) , without modules
Data for application in connection with hazardous areas
CertificatePF 08 CERT 1234 X
MarkingEx-Hexagon II 3 G Ex nA IIC T4 Gc
Directive conformity
Directive 2014/34/EUEN 60079-0:2009
EN 60079-15:2010
International approvals
ATEX approvalPF 08 CERT 1234 X
UL approvalE106378
Control drawing116-0321
Approved forcUL (Canada): CL I Zn. 2 IIC; IS circuits for CL I Zn. 0 IIC
ULus (USA): CL I Div. 2 Grp. A, B, C, D; IS circuits for CL I, II, III Div. 1 Grp. A, B, C, D, E, F, G
IECEx approvalBVS 09.0037X
Approved forEx nA IIC T4 Gc
EAC approvalRussia: RU C-IT.MIII06.B.00129
Marine approval
Lloyd Register15/20021
DNV GL MarineTAA0000034
American Bureau of ShippingT1450280/UN
Bureau Veritas Marine22449/B0 BV

Documents: LB9029A

ManualsLanguageFile TypeFile Size
Manual LB HardwareENGPDF3826 KB
Handbuch LB-HardwareGERPDF3830 KB
Instructions, short instructions, safety information
ИнструкцииBULPDF134 KB
Návod k poużitíCZEPDF129 KB
Instruktions manualDANPDF128 KB
Instruction manualENGPDF53 KB
KasutusjuhendESTPDF125 KB
KäyttöohjeFINPDF0 KB
Manuel d'instructionsFRAPDF69 KB
BetriebsanleitungGERPDF55 KB
Οδηγίες χρήσηςGREPDF138 KB
HandleidingHOLPDF0 KB
Instruction manual / BetriebsanleitungHRVPDF0 KB
Használati útmutatóHUNPDF130 KB
Manuale di istruzioniITAPDF66 KB
Lietošanas pamācībaLAVPDF128 KB
Instrukciju vadovasLITPDF0 KB
Instrukcja obsługiPOLPDF0 KB
Manual de instruçõesPORPDF0 KB
Manual de utilizareRONPDF128 KB
Návod na poużitieSLKPDF129 KB
Navodila za uporaboSLVPDF127 KB
Manual de instruccionesSPAPDF67 KB
ManualSWEPDF127 KB

Approvals+Certificates: LB9029A

Statements of complianceCertificate No.File TypeFile Size
EU-Declaration of conformity / EU-KonformitätserklärungDOC-1048CPDF233 KB
Certificates
American Bureau of Shipping (ABS) Marine15-HG1450280-PDAPDF1468 KB
Bureau Veritas (Maritime) Marine22449/B0 BVPDF287 KB
Canada UL cULE106378 cUL (QUZW7)LINK---
DEKRA EXAM IECEx Certificate of ConformityIECEx BVS 09.0037XLINK---
DNV GL MarineTAA0000034PDF334 KB
Europe Pepperl+Fuchs II 3 G Declaration of ConformityPF 08 CERT 1234 XPDF1503 KB
Lloyd's Register Marine15/20021PDF2013 KB
USA ULE106378 UL (QUZW)LINK---
Control drawings
Control Drawing UL, cUL / Control Drawing UL, cUL   PDF40 KB

Associated Products: LB9029A

Matching system components
Standard enclosure for LB-System, Max. 12 slots for I/O modules, Installation in Zone 2 or safe area, For PROFIBUS DP, PROFIBUS DP V1 and MODBUS RTU, Housing: polyester , impact resistant, glass fiber reinforcedpa
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Communication via PROFIBUS DP, Mounting in Zone 2, Class I/Div.2 or in the safe areapa
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Communication via PROFIBUS DP, Mounting in Zone 2, Class I/Div.2 or in the safe areapa
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Communication via PROFIBUS DP, Mounting in Zone 2, Class I/Div.2 or in the safe areapa
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Communication via PROFIBUS DP, Mounting in Zone 2, Class I/Div.2 or in the safe areapa
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Communication via PROFIBUS DP, Mounting in Zone 2, Class I/Div.2 or in the safe areapa
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Communication via PROFIBUS DP, Mounting in Zone 2, Class I/Div.2 or in the safe areapa
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Communication via PROFIBUS DP, Mounting in Zone 2, Class I/Div.2 or in the safe areapa
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Communication via PROFIBUS DP, Mounting in Zone 2, Class I/Div.2 or in the safe areapa
Interface between the I/O modules and the PCS/PLC, Com unit for 20 analog or 40 digital channels, Communication via FOUNDATION Fieldbus H1, Mounting in Zone 2, Class I/Div.2 or in the safe areapa
Matching system components

Max. 24 slots for I/O modules, 5 SIL 2 output shutdown segments, Redundancy (power supply), Fieldbus type determined by base backplanepa