General specifications
Passage speed≤ 8 m/s
Measuring rangemax. 10000 m
Light typeIntegrated LED lightning (white/blue)
Read distance100 mm
Depth of focus± 20 mm
Reading field120 mm x 80 mm
Ambient light limit100000 Lux
Resolution± 0.2 mm  
Nominal ratings
Camera
TypeCMOS , Global shutter
Processor
Clock pulse frequency600 MHz
Speed of computation4800 MIPS
Functional safety related parameters
MTTFd99 a
Mission Time (TM)49 a
Diagnostic Coverage (DC)0 %
Indicators/operating means
LED indicator7 LEDs (communication, alignment aid, status information)
Electrical specifications
Operating voltage15 ... 30 V DC , PELV
No-load supply currentmax. 400 mA
Power consumption6 W
Interface
Interface typeCANopen , galvanically isolated
Data output codebinary code
Transfer ratemax. 1 MBit/s
Interface 2
Interface typeUSB Service
Input
Input type1 funtion input
0-level: -UBor unwired
1-level: +8 V ... +UB , programmable
Input impedance≥ 27 kΩ
Output
Output type1 to 3 switch outputs ,     programmable , short-circuit protected
Switching voltageOperating voltage
Switching current150 mA each output
Standard conformity
Emitted interferenceEN 61000-6-4:2007+A1:2011    
Noise immunityEN 61000-6-2:2005    
Shock resistanceEN 60068-2-27:2009
Vibration resistanceEN 60068-2-6:2008
Approvals and certificates
UL approvalcULus Listed, General Purpose, Class 2 Power Source, Type 1 enclosure
CCC approvalCCC approval / marking not required for products rated ≤36 V
Ambient conditions
Operating temperature0 ... 60 °C (32 ... 140 °F) ,   -20 ... 60 °C (-4 ... 140 °F) (noncondensing; prevent icing on the lens!)
Relative humidity90 % , noncondensing
Mechanical specifications
Connection type8-pin, M12x1 connector, standard (supply+IO)
5-pin, M12x1 socket, A-coded (bus out/termination)
5-pin, M12x1 connector, A-coded (bus in)
Housing width70 mm
Housing height70 mm
Housing depth50 mm
Degree of protectionIP67
Material
HousingPC/ABS
Massapprox. 200 g

Documents: PGV100-F200A-B16-V15

ManualsLanguageFile TypeFile Size
Manual Code Cards to configure the fieldbus addressENGPDF5321 KB
Manual PGV*-F200*-B16-V15ENGPDF4858 KB
Handbuch Codekarten zur Konfiguration der FeldbusadresseGERPDF5326 KB
Handbuch PGV*-F200*-B16-V15GERPDF3946 KB
Instruction leaflets
Instruction leaflet / Beipackzettel ALLPDF597 KB

Approvals+Certificates: PGV100-F200A-B16-V15

Statements of complianceCertificate No.File TypeFile Size
EU-Declaration of Conformity / EU-KonformitätserklärungDOC-1998EPDF95 KB

Software: PGV100-F200A-B16-V15

DriversRelease InfoFile TypeFile Size
EDS file PGV...-F200x-B16-V15 / EDS-Datei PGV...-F200x-B16-V1505/2016ZIP3 KB
Software Tools
Software Vision Configurator / Software Vision ConfiguratorV6.0.00.4814ZIP20670 KB

Associated Products: PGV100-F200A-B16-V15

Matching system components
Data Matrix code tape, High chemical resistance, Low weight, Self-adhesive mounting, High temperature resistance, High mechanical stabilityfa
Blind plug for M12 socketsfa
Control code tape für PGV System, High chemical resistance, Low weight, Self-adhesive mounting, High temperature resistance, High mechanical stabilityfa
Protective film for PGV code tape, High chemical resistance, Low weight, Self-adhesive mounting, High temperature resistance, High mechanical stabilityfa
Accessories

Female cordset, M12, 8-pin, shielded, PUR cablefa
Grounding clip for PCV system, Stainless steel version, Low weight, M12 plug connection, High mechanical stabilityfa
Terminal resistor for DeviceNet, CANopenfa
Marker head for 25 mm code tape, For 25 mm code tapes, Can be used for PCV80..., PCV100..., and PCV130... readers, Includes 2 x edding® 3000 permanent markersfa
Mounting bracket for PCV* read headfa
DeviceNet/CANopen bus cable, M12, PUR cable, 5-pinfa
DeviceNet/CANOpen bus cable, M12 to M12, PUR cable 5-pinfa
DeviceNet/CANOpen bus cable, M12 to M12, PUR cable 5-pinfa
Female cordset, M12, 8-pin, shielded, PUR cablefa
Female cordset, M12, 8-pin, shielded, PUR cablefa
PGV color-tape blue, Self-adhesive mounting, High mechanical stabilityfa
PGV color-tape green, Self-adhesive mounting, High mechanical stabilityfa
PGV color-tape red, Self-adhesive mounting, High mechanical stabilityfa
PGV color-tape yellow, Self-adhesive mounting, High mechanical stabilityfa
Operating software for camera-based sensorsfa
USB cable unit with power supply, Power supply for 95 - 230 V AC, For SSI interface, For PROFIBUS DP, For CANopen, For PROFINET, For EtherNet/IPfa
Functional Safety Hub from Pepperl+Fuchs

Several hundred products with a SIL/PL assessment, free tools, and brochures in one place: the "Functional Safety Hub" is your starting point when you have to implement safety functions.

Absolute positioning systems safePXV and safePGV