Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Download the complete datasheet as a PDF:
Application | ||
---|---|---|
Function principle | Limit detection maximum or minimum detection in tanks or pipelines containing liquids of any kind, even in hazardous areas |
|
Function and system design | ||
Measuring principle | The forks of the sensors vibrate at their intrinsic frequency. This frequency is reduced when covered with liquid. The change in frequency then activates the limit switch. |
|
Input characteristics | ||
Measured variable | limit level (limit value) | |
Measurement range | LVL-M1: depends on mounting point LVL-M2: depends on mounting point and pipe extension up to 6000 mm (20 ft) |
|
Medium density | adjustment on the electronic insert > 0,5 g/cm3 or > 0,7 g/cm3 (other on request) | |
Output characteristics | ||
Fail-safe mode | switch-over for minimum/maximum residual current safety on electronic insert MAX = maximum safety: The output switches to the power fail response when the fork is covered. for use with overspill protection for example MIN = minimum safety: The output switches to the power fail response when the fork is exposed. for use with dry running protection for example |
|
Switching time | when fork is covered: approx. 0.5 s, when fork is exposed: approx. 1.0 s (other switching times on request) additionally configurable for PROFIBUS PA (electronic insert FEL50A (PA)): 0.5 ... 60 s |
|
Switch-on response | When switching on the power supply the output assumes the alarm signal. After max. 2 s it assumes the correct switching mode. | |
Auxiliary energy | ||
Supply voltage | electronic insert FEL50A (PA): 9 ... 32 V DC electronic insert FEL51 (AC): 253 V AC, 50/60 Hz electronic insert FEL52 (E5): 10 ... 55 V DC electronic insert FEL54 (WA): 19 ... 253 V AC, 50/60 Hz or 19 ... 55 V DC electronic insert FEL55 (SI): 11 ... 36 V DC, PLC electronic insert FEL56 (N1), FEL58 (N2): isolating amplifier acc. to EN 60947-5-6 (NAMUR) |
|
Connecting cable | electronic inserts: cross section max. 2.5 mm2, lace in end splice in acc. with DIN 46228 ground lead in housing: cross section max. 2.5 mm2 external equipotential bonding: cross section 4 mm2 |
|
Power consumption | electronic insert FEL52 (E5): max. 0.83 W electronic insert FEL54 (WA): max. 1.3 W |
|
Current consumption | electronic insert FEL52 (E5): max. 15 mA | |
Measurement accuracy | ||
Reference operating conditions | ambient temperature: 23 °C (73.4 °F), medium temperature: 23 °C (73.4 °F), product density: 1 g/cm3 (water), viscosity: 1 mm2/s, medium pressure pe: 0 bar, sensor mounting: vertical from above, density switch: to > 0.7 g/cm3 |
|
Maximum measured error | max. ± 1 mm, specified by mounting position | |
Non-repeatability | 0.1 mm | |
Hysteresis | approx. 2 mm | |
Influence of medium density | max. +4.8 ... -3.5 mm (0.5 ... 1.5 g/cm3) | |
Influence of medium temperature | max. +1.4 ... -2.8 mm (-40 ... 150 °C (-40 ... 302 °F)) | |
Influence of medium pressure | max. 0 ... -2.5 mm (-1 ... 64 bar) | |
Operating conditions | ||
Installation conditions | ||
Installation position | LVL-M1: any position LVL-M2: with short pipe (up to 500 mm (19.7 inch)) any position, with long pipe vertical |
|
Ambient conditions | ||
Ambient temperature | -50 ... 70 °C (223 ... 343 K) , function with reduced data values see section ambient temperature |
|
Storage temperature | -50 ... 80 °C (223 ... 353 K) | |
Overvoltage protected | electronic insert FEL51 (AC), electronic insert FEL52 (E5), electronic insert FEL54 (WA), electronic insert FEL55 (SI): overvoltage category III | |
Process conditions | ||
Medium temperature | -50 ... 150 °C (-58 ... 302 °F), for exceptions see process connections | |
Medium pressure | pe = -1 ... 64 bar (-14.5 ... 928.3 psi) over the entire temperature range , exceptions see process connections | |
Test pressure | max. 100 bar (1.5 times the medium pressure pe), no function during test pressure, burst pressure of diaphragm 200 bar | |
Thermal shock resistance | max. 120 °C/s (max. 120 K/s) | |
State of aggregation | liquid | |
Density | min. 0.5 g/cm3 (compact housing 0.7 g/cm3), other density settings on request | |
Viscosity | max. 10000 mm2/s (max. 10000 cSt) | |
Solid contents | max. ∅ 5 mm | |
Mechanical specifications | ||
Degree of protection | polyester, steel, and aluminum housing: IP66/IP67 compact housing: - IP65 with valve connector PG11 or 1/2NPT - IP66/IP68 with M12 x 1 connector without LEDs (1.4435/316L) - IP69K with M12 x 1 connector with LEDs (1.4435/316L) |
|
Mechanical construction | ||
Construction type | LVL-M1: compact design LVL-M2: version with extension tube |
|
Dimensions | housing: diameter max. 85 mm, height max. 173 mm temperature separator, flameproof bushing: additional length L 140 mm process connection: length L 66.5 ... 80 mm extension: any length L from 148 ... 3000 mm, depending on the process connection extension: length type II, for vertical installation from above same switching point as Vibracon LVL1, LVL2 vibration fork: width 17.5 mm, fork width 10 mm, length 25 mm |
|
Mass | 600 g , basic weight: compact sensor, electronic insert, stainless steel housing, process connection G2*, additional weight is dependent on extension tube, housing and process connection | |
Additional weight | process connections: - A3* 1000 g, A4* 1200 g, A5* 1500 g, A6* 2400 g, A72 4800 g, A81 4900 g, A82 6800 g, A91 7000 g, A92 11.5 kg, A93 17.3 kg - C45 1400 g, C51 1200 g, C71 1600 g, C75 3200 g, C95 5900 g, CA3 5600 g - D45 1400 g, D51 1200 g, D71 1600 g, D75 3200 g, D7A 300 g, D7D 300 g, D95 5900 g, DA3 5600 g - F45 1400 g, F51 1200 g, F55 2000 g, F61 1400 g, F65 2400 g, F71 1600 g, F75 3200 g, F7F 2600 g, F81 2400 g, F85 4300 g, F93 4800 g, F95 5900 g, FA3 5600 g, FA5 7500 g - G3* 200 g - J13 no information, J16 no information, J17 1700 g, J19 no information, J1A no information, J1C 1700 g - N3* 200 g, N75 2900 g - R3* 200 g - T51 no information, T61 100 g extension tube, tempeprature spacers, flameproof bushings: - B* 900 g/m, C* 2300 g/100 inch - D* 100 g - J* 900 g/m and 600 g, K* 2300 g/100 inch and 600 g - L* 700 g - R* 900 g/m and 700 g, S* 2300 g/100 inch and 700 g - T* 800 g |
|
Material | wetted parts: - process connection and extension tube: 1.4435/316L or 2.4610/Alloy C4 - vibration fork: 1.4435/316L or 2.4610/Alloy C4 - flat seal for process connection G2* or G3*: elastomer fibre, asbestos-free housings: - polyester housing: PBT-FR with PBT-FR cover or with PA12 cover with sight glass, cover seal: EPDM - stainless steel housing: 1.4435/316L, cover seal: silicone - aluminum housing: EN-AC-AlSi10Mg, plastic-coated, cover seal: EPDM - compact housing with valve connector or M12 connector: 1.4435/316L cable gland: polyamide or brass, nickel-plated temperature spacer: 1.4435/316L flameproof bushing: 1.4435/316L |
|
Surface quality | Ra < 3.2 µm/80 grit: length, spacer, bushings *A, *B, *E | |
Switching point | see section switch point | |
Process connection | - cylindrical thread G3/4A, G1A to DIN ISO 228/1 with flat seal to DIN 7603 - conical thread R3/4, R1 to DIN 2999, part 1 - conical thread 3/4NPT, 1NPT to ANSI B 1.20.1 - flush-mounted with welding sleeve to factory standard (G3/4A, G1A) - flush-mounted with welding neck to factory standard (1 inch), sensor can be positioned - Triclamp 1-1/2 inch, 2 inch to ISO 2852 - flanges to EN 1092-1 from DN25, to ANSI B 16.5 from 1 inch, to JIS B 2238 (RF) from DN25 For further information see type code. |
|
Indication and operation | ||
Display elements | electronic inserts: - electronic inserts FEL50 A (PA), FEL58 (N2): green LED, yellow LED - electronic inserts FEL51 (AC), FEL52 (E5), FEL54 (WA), FEL55 (SI), FEL56 (N1): green LED, red LED compact housings: compact housing with valve connector - electronic version FEL51 (AC), FEL52 (E5): green LED, red LED - electronic version FEL58 (N2): green LED, yellow LED compact housing with M12 x 1 round connector without LEDs - electronic version FEL52 (E5): green LED, yellow LED, red LED - electronic version FEL58 (N2): green LED, yellow LED compact housing with M12 x 1 round connector with LEDs - electronic version FEL52 (E5): green LED, two yellow LEDs |
|
Control elements | electronic insert FEL50A (PA): 8 switches for device address setting electronic inserts FEL51 (AC), FEL52 (E5), FEL54 (WA), FEL55 (SI), FEL56 (N1): two switches for fail-safe mode and density change electronic insert FEL58 (N2): two switches for fail-safe mode and density change and one test button interrupts lead |
|
Function test | compact housing: function test with test magnet electronic versions FEL51 (AC), FEL52 (E5) and FEL58 (N2): During the test, the current state of the electronic switch is reversed. |
|
Certificates and approvals | ||
Explosion-hazardous area | KEMA 01 ATEX 1089, KEMA 01 ATEX 1147 X, KEMA 01 ATEX 2117 , for additional certificates see www.pepperl-fuchs.com | |
Type of protection | II 1/2G EEx ia IIC T3 ... T6 or EEx ia IIB T3 ... T6 and II 1/2D T80°C (KEMA 01 ATEX 1089) II 1G EEx ia IIC T3 ... T6 or EEx ia IIB T3 ... T6 (KEMA 01 ATEX 1147 X) II 1/2G EEx d IIC T3 ... T6 or EEx d IIB T3 ... T6 (KEMA 01 ATEX 2117) II 3G EEx nA/nC II T6 and II 3D T85°C |
|
SIL classification | up to SIL2 acc. to IEC 61508 | |
Overspill protection | Z-65.11-306 (overspill protection in acc. with WHG) | |
General information | ||
Directive conformity | ||
Directive 73/23/EEC | EN 61010-1 | |
Directive 89/336/EEC (EMC) | emitted interference to EN 61326, class B equipment noise immunity to EN 61326, annex A (industrial sector) If the fork tines are joined together on account of build-up, the useful signal is attenuated to such an extent that the original EMC values can no longer be completely observed (EN 61000-4-3 electromagnetic fields, EN 61000-4-6 HF coupling). |
|
Directive 94/9/EC (ATEX) | EN 50014, EN 50018, EN 500020, EN 500021, EN 50284, EN 50281-1-1 | |
Conformity | ||
Electromagnetic compatibility | NE 21 | |
Degree of protection | EN 60529 | |
Climate class | EN 60068, part 2-38, fig. 2a | |
Vibration resistance | EN 60068-2-6 , 10 ... 50 Hz, 0.15 mm, 100 cycles | |
Supplementary documentation | technical information TI328O operating instructions KA143O (LVL-M*) operating instructions KA220O (LVL-M** with compact housing) operating instructions BA141O (electronic insert FEL50A (PA)) operating instructions KA140O weld-in socket G1 (LVL-Z102) operating instructions KA141O weld-in adapter G1 (LVL-Z101) operating instructions KA142O weld-in adapter G¾ (LVL-Z100) operating instructions KA151O sliding sleeve for unpressurised operation G1A, 1 NPT (LVL-Z120, LVL-Z122) operating instructions KA152O sliding sleeve for unpressurised operation G1½A, 1½ NPT (LVL-Z121, LVL-Z123) operating instructions KA153O high pressure sliding sleeve G1A, 1 NPT (LVL-Z124, LVL-Z125, LVL-Z128, LVL-Z129) operating instructions KA154O high pressure sliding sleeve G1A, 1 NPT (LVL-Z126, LVL-Z127, LVL-Z130, LVL-Z131) safety information SI031O (KEMA 01 ATEX 2117) safety information SI063O (KEMA 01 ATEX 1089) safety information SI064O (KEMA 01 ATEX 1147 X) safety information SI154O (KEMA 01 ATEX 1089), PROFIBUS PA version safety information SI159O (KEMA 01 ATEX 11147 X), PROFIBUS PA version safety information SI182O ( II 3G EEx nA/nC II T6 and II 3D T85°C) approval ZE233O overspill protection acc. to WHG (Z-65.11-306) FM installation drawing ZD041O CSA control drawing ZD042O |
|
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
System | Classcode |
---|---|
ECLASS 13.0 | 27200518 |
ECLASS 12.0 | 27200518 |
ECLASS 11.0 | 27200518 |
ECLASS 10.0.1 | 27200518 |
ECLASS 9.0 | 27200589 |
ECLASS 8.0 | 27200589 |
ECLASS 5.1 | 27200589 |
ETIM 9.0 | EC001447 |
ETIM 8.0 | EC001447 |
ETIM 7.0 | EC001447 |
ETIM 6.0 | EC001447 |
ETIM 5.0 | EC001447 |
UNSPSC 12.1 | 41111950 |
Device Description Files/Drivers | Release Info | File Type | File Size |
---|---|---|---|
GSD / GSD | ZIP | 5 KB |
Accessories | ||||||
---|---|---|---|---|---|---|
|