Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Download the complete datasheet as a PDF:
Product Description | ||
---|---|---|
EtherNet/IP IO-Link master with 8 inputs/outputs |
General specifications | ||
---|---|---|
UL File Number | E360395 | |
Indicators/operating means | ||
LED indication | see manual | |
Rotary switch | Setting the IP address | |
Electrical specifications | ||
Rated operating voltage | 20 ... 30 V DC | |
Nominal voltage | 24 V DC | |
Current consumption | typ. 120 mA | |
Current loading capacity | Max. 2 x 16 A per module (Loop-through current via L-coded power supply) Total current: max. 6.7 A per module |
|
Galvanic isolation | between US and UA | |
Interface 1 | ||
Interface type | Industrial Ethernet | |
Physical | M12, D-coded | |
Protocol | EtherNet/IP + Modbus TCP + OPC UA | |
Transfer rate | 10/100 Mbps | |
Inputs/Outputs | ||
Number/Type | 8 x IO-Link Class A (X1 – X8)
Configurable as:
Max. 8 IO-Link and 8 digital inputs
Max. 16 digital inputs
Max. 8 digital inputs and 8 digital outputs short-circuit protected |
|
Sensor supply | Port 1: max. 1.6 A Via L+ (pin 1) Port 3: max. 1 A via L+ (pin 1) Ports 2 and 4 – 8: max. 500 mA per port via L+ (pin 1) |
|
Output rated operating current | max. 200 mA Per port via C/Q (pin 4) | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61000-6-2 , EN 61000-6-4 | |
Standard conformity | ||
Degree of protection | EN 60529 | |
Fieldbus standard | Type 1 according to IEC 61131-2, EN 61131-9 | |
Electrical safety | CSA C22.2 No. 61010-1-12 UL 61010-1, IEC 61010-2-201 |
|
Emitted interference | EN 61000-6-4, FCC Part 15 Subpart B, ICES-001, AS/NZS CISPR 11 | |
Noise immunity | EN 61000-6-2 , EN 61131-2 , EN 61131-9 | |
Shock resistance | EN 60068-2-27 | |
Ambient conditions | ||
Ambient temperature | -25 ... 60 °C (-13 ... 140 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | max. 95 % | |
Altitude | 0 ... 2000 m | |
Shock and impact resistance | 15g, 11ms, half-sine | |
Mechanical specifications | ||
Housing length | 30 mm | |
Housing width | 65 mm | |
Housing height | 212 mm | |
Degree of protection | IP67 | |
Connection | Power Supply M12, L-coded Fieldbus M12, D-coded Inputs/Outputs M12, A-coded |
|
Material | ||
Housing | Molded Polyamide 66 | |
Mass | 454 g | |
Tightening torque, fastening screws | 8 Nm | |
Tightening torque, cable gland | max. 0.5 Nm |
Manuals | Language | File Type | File Size |
---|---|---|---|
ICE2/ICE3 MQTT | ENG | 880 KB | |
Manual | ENG | 27177 KB | |
Handbuch | GER | 19017 KB |
CAD | File Type | File Size | |
---|---|---|---|
3-D model in IGS format / 3-D-Modell im IGS-Format | IGS | 20978 KB | |
3-D model in STP format / 3-D-Modell im STP-Format | STP | 6572 KB |
Statements of compliance | Certificate No. | File Type | File Size |
---|---|---|---|
EU-Declaration of conformity / EU-Konformitätserklärung | DOC-4275B | 258 KB | |
Certificates | |||
Canada, USA UL UL | E360395 | LINK | --- |
Korea | R-R-PF1-C0087 | 316 KB | |
Worldwide IO-Link Manufacturer Declaration | CERT-5231A | 56 KB |
Commissioning files | Language | File Type | File Size |
---|---|---|---|
AOI (Add On Instruction) files for RSLogix 5000 / AOI (Add On Instruction) Dateien für RSLogix 5000 | ALL | ZIP | 2070 KB |
Software Tools | Release Info | File Type | File Size |
---|---|---|---|
EtherNet/IP EDS files ICE2 modules / EtherNet/IP EDS-Dateien ICE2 Module | 11/2020 | ZIP | 33 KB |
Ethernet/IP Tag Description Generator. Assists the user in visualizing the input, output, status and event data. Also can generate a CSV file for upload in to RSLogix/Studio 5000. / Software Tools_a | 01/2021 | ZIP | 26974 KB |
PortVision DX v5.02 / PortVision DX v5.02 | 2020-03 | ZIP | 26026 KB |
Accessory of | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
|
||||||
|
||||||
Matching System Components | ||||||
|
||||||
Accessories | ||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
The module is an EtherNet/IP fieldbus module with 8 type A IO-Link master ports according to IO-Link standard V1.1.
The fieldbus module serves as an interface between the controller of an EtherNet/IP fieldbus system and IO-Link devices in the field level.
The integrated web server and IODD interpreter enabling complete configuration of the fieldbus module and attached IO-Link devices without the need for special software tools. Information regarding the status of the module is also displayed and network parameters such as the IP address and subnet mask can be configured. The module is capable of storing all configuration enabling stand-alone usage without a higher-level PLC. MutliLink simultaneously provides data access via different communication protocols like EtherNet/IP, Modbus/TCP and OPC UA to multiple controllers. An L-coded M12 connector plug used for supplying power enables a current rating of up to 2 x 16 A.
The inputs and outputs are equipped with A-coded M12 connector plugs. Connection to the fieldbus is achieved using a D-coded M12 connector plug.
Status information for each channel is displayed via LEDs as a diagnostic function.