Serviceline
Serviceline Industrial Sensors
Serviceline Explosion Protection

SMART Transmitter Power Supply HiD2022

HiD2022
  • 2-channel isolated barrier
  • 24 V DC supply (bus powered)
  • Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources
  • Output 0/4 mA ... 20 mA current source
  • Up to SIL 2 acc. to IEC 61508

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of HiD2022

General specifications
Signal typeAnalog input
Functional safety related parameters
Safety Integrity Level (SIL)SIL 2
Supply
ConnectionSL1: 1a(-), 1b(-); 2a(+), 2b(+)
Rated voltage18 ... 30 V DC bus powered via Termination Board
Ripplewithin the supply tolerance
Power dissipation≤ 1.4 W
Power consumption≤ 2.6 W
Input
Connection sidefield side
ConnectionSL2: 5a(+), 5b, 7a(-); 1a(+), 1b, 3b(-)
Input signal0/4 ... 20 mA , current limit 27 mA
Input resistancemax. 265 Ω SL2: 5b, 7a; 1b, 3b ; max. 330 Ω SL2: 5a, 7a; 1a, 3b
Available voltage≥ 16 V at 20 mA , SL2: 5a(+), 5b(-); 1a(+), 1b(-)
Output
Connection sidecontrol side
ConnectionSL1: 8a(+), 7a(-); 10a(+), 9a(-)
Load0 ... 650 Ω
Output signal0/4 ... 20 mA (overload > 25 mA)
Ripplemax. 50 µA rms
Transfer characteristics
Deviationat 20 °C (68 °F), 0/4 ... 20 mA
≤ 10 µA incl. calibration, linearity, hysteresis, loads and fluctuations of supply voltage
Influence of ambient temperature≤ 0.25 µA/K
Frequency rangefield side into the control side: band width with 1 Vpp signal 0 ... 7.5 kHz (-3 dB)
safe area to hazardous area: band width with 1 VSS signal 0.3 ... 7.5 kHz (-3 dB)
Settling time200 µs
Rise time/fall time100 µs
Galvanic isolation
Output/power supplyfunctional insulation, rated insulation voltage 50 V AC
Output/Outputfunctional insulation, rated insulation voltage 50 V AC
Indicators/settings
Display elementsLED
Labelingspace for labeling at the front
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Conformity
Electromagnetic compatibilityNE 21:2012
EN 61326-3-2:2008
Degree of protectionIEC 60529:2001
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Relative humidity5 ... 90 %, non-condensing up to 35 °C (95 °F)
Mechanical specifications
Degree of protectionIP20
Massapprox. 140 g
Dimensions18 x 106 x 128 mm (0.7 x 4.2 x 5 inch)
Mountingon Termination Board
Codingpin 1 and 3 trimmed
For further information see system description.
Data for application in connection with hazardous areas
EU-Type Examination CertificateCML 17 ATEX 2143X
MarkingEx-Hexagon II (1)G [Ex ia Ga] IIC
Ex-Hexagon II (1)D [Ex ia Da] IIIC
Ex-Hexagon I (M1) [Ex ia Ma] I
Input[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
Supply
Maximum safe voltage250 V (Attention! The rated voltage can be lower.)
EquipmentSL2: 5a(+), 5b(-); 1a(+), 1b(-)
Voltage Uo26.2 V
Voltage Uq27.25 V
Current Io93 mA
Power Po634 mW
EquipmentSL2: 5b(+), 7a(-); 1b(+), 3b(-)
Voltage Ui30 V
Current Ii115 mA
Power Pimax 1 W
Voltage Uo2 V
Current Io8.5 mA
Power Po4.3 mW
EquipmentSL2: 5a(+), 5b, 7a(-); 1a(+), 1b, 3b(-)
Voltage Uo26.2 V
Voltage Uq27.25 V
Current Io115 mA
Power Po784 mW
CertificateCML 17 ATEX 3144X
MarkingEx-Hexagon II 3G Ex ec IIC T4 Gc
Galvanic isolation
Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11:2012, voltage peak value 375 V
Input/power supplysafe electrical isolation acc. to IEC/EN 60079-11:2012, voltage peak value 375 V
Directive conformity
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-7:2015
International approvals
UL approval
Control drawingpending
IECEx approvalIECEx CML 17.0072X
Approved for[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
General information
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Documents: HiD2022

ManualsLanguageFile TypeFile Size
Functional Safety ManualENGPDF697 KB
Manual H-System Isolated Barriers and Termination BoardsENGPDF5551 KB
Handbuch Funktionale SicherheitGERPDF664 KB
Handbuch Trennbarrieren und Termination Boards H-SystemGERPDF5543 KB
Instruction manuals
ИнструкцииBULPDF63 KB
Návod k poużitíCZEPDF59 KB
Instruktions manualDANPDF57 KB
Instruction manualENGPDF49 KB
KasutusjuhendESTPDF54 KB
KäyttöohjeFINPDF55 KB
Manuel d'instructionsFRAPDF69 KB
BetriebsanleitungGERPDF51 KB
Οδηγίες χρήσηςGREPDF67 KB
HandleidingHOLPDF68 KB
Instruction manual / BetriebsanleitungHRVPDF67 KB
Használati útmutatóHUNPDF68 KB
Manuale di istruzioniITAPDF67 KB
Lietošanas pamācībaLAVPDF67 KB
Instrukciju vadovasLITPDF66 KB
Instrukcja obsługiPOLPDF70 KB
Manual de instruçõesPORPDF69 KB
Manual de utilizareRONPDF68 KB
Návod na poużitieSLKPDF128 KB
Manual de instruccionesSPAPDF68 KB
ManualSWEPDF65 KB

Approvals+Certificates: HiD2022

CertificatesCertificate No.File TypeFile Size
Belarus Pattern ApprovalNr. 11708PDF8943 KB
CML [Ex ia] Ex ec IECEx Certificate of ConformityIECEx CML 17.0072XLINK---
EAC EAC TP TC 020/2011TC RU C-DE.MH04.B.00397PDF680 KB
Europe CML ATEX Category 3 GCML 17 ATEX 3144XPDF124 KB
Europe CML I (M1) II (1) D ATEX II (1) GCML 17 ATEX 2143XPDF140 KB
Russia EAC Kazakhstan BelarusTC RU C-DE.AA71.B.00291PDF2516 KB
Russia VNIIMSDE.C.34.004.A No.64324/1PDF10397 KB
Worldwide TUV Rheinland968/FSP 1498.00/17 ENPDF679 KB