Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Download the complete datasheet as a PDF:
Product Description | ||
---|---|---|
Distance sensor |
General specifications | ||
---|---|---|
Measurement range | 100 ... 300 mm | |
Reference target | standard white, 100 mm x 100 mm | |
Light source | LED | |
Light type | modulated visible red light | |
LED risk group labelling | exempt group | |
Angle deviation | max. +/- 1.5 ° | |
Diameter of the light spot | approx. 8 mm at a distance of 300 mm | |
Angle of divergence | 1.8 ° | |
Ambient light limit | EN 60947-5-2 : 45000 Lux | |
Resolution | 0.1 mm | |
Functional safety related parameters | ||
MTTFd | 600 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
Operation indicator | LED green: constantly on - power on flashing (4Hz) - short circuit flashing with short break (1 Hz) - IO-Link mode |
|
Function indicator | LED yellow: constantly on - switch output active constantly off - switch output inactive |
|
Control elements | Teach-In key | |
Control elements | 5-step rotary switch for operating modes selection | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
Ripple | max. 10 % | |
No-load supply current | < 25 mA at 24 V supply voltage | |
Protection class | III | |
Interface | ||
Interface type | IO-Link ( via C/Q = pin 4 ) | |
Device profile | Identification and diagnosis Smart Sensor type 0/type 3.3 |
|
Transfer rate | COM 2 (38.4 kBaud) | |
IO-Link Revision | 1.1 | |
Min. cycle time | 3 ms | |
Process data width | Process data input 4 byte Process data output 2 bits |
|
SIO mode support | yes | |
Device ID | 0x111904 (1120516) | |
Compatible master port type | A | |
Output | ||
Switching type | The default setting is: C/Q - Pin4: NPN normally open, PNP normally closed, IO-Link Q2 - Pin2: NPN normally open, PNP normally closed |
|
Signal output | 2 push-pull (4 in 1)outputs, short-circuit protected, reverse polarity protected, overvoltage protected | |
Switching voltage | max. 30 V DC | |
Switching current | max. 100 mA , resistive load | |
Usage category | DC-12 and DC-13 | |
Voltage drop | ≤ 1.5 V DC | |
Response time | 2 ms , see table 1 | |
Conformity | ||
Communication interface | IEC 61131-9 | |
Product standard | EN 60947-5-2 | |
Measurement accuracy | ||
Temperature drift | 0.05 %/K | |
Warm up time | 5 min | |
Repeat accuracy | < 0.5 % , see table 1 | |
Linearity error | 0.5 % | |
Approvals and certificates | ||
UL approval | E87056 , cULus Listed , class 2 power supply , type rating 1 | |
CCC approval | CCC approval / marking not required for products rated ≤36 V | |
Ambient conditions | ||
Ambient temperature | 10 ... 60 °C (50 ... 140 °F) | |
Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Mechanical specifications | ||
Housing width | 15 mm | |
Housing height | 50.6 mm | |
Housing depth | 41.7 mm | |
Degree of protection | IP67 / IP69 / IP69K | |
Connection | 4-pin, M12 x 1 connector, 90° rotatable | |
Material | ||
Housing | PC (Polycarbonate) | |
Optical face | PMMA | |
Mass | approx. 37 g |
Technical information | Language | File Type | File Size |
---|---|---|---|
Installation and user instructions for offline parameterization of IO-Link sensors | ENG | 1788 KB | |
Installations-/Benutzeranweisungen für die Offline-Parametrierung von IO-Link-Sensoren | GER | 1764 KB | |
Product information | |||
Product information R10x and R20x Series Standard Housings - All Sensing Modes | ENG | 1783 KB | |
Produktinformation Serien R10x und R20x Alle Funktionsprinzipien - In Standardgehäusen | GER | 1799 KB |
CAD | File Type | File Size | |
---|---|---|---|
3-D model in IGS format / 3-D-Modell im IGS-Format | IGS | 3055 KB | |
3-D model in STP format / 3-D-Modell im STP-Format | STP | 1499 KB | |
CAD Portal / CAD Portal | LINK | --- | |
EPLAN | |||
EPLAN Data Portal / EPLAN Data Portal | LINK | --- | |
EPLAN macro P+F.OMT300-R200-2EP-IO-V1 / EPLAN-Makro P+F.OMT300-R200-2EP-IO-V1 | EDZ | 72 KB |
Statements of compliance | Certificate No. | File Type | File Size |
---|---|---|---|
Declaration of Conformity for simple apparatus / Konformitätserklärung für einfache Betriebsmittel | DOC-3935 | 162 KB | |
Certificates | |||
Canada USA UL Ordinary Location | 20170306-E87056 | 407 KB | |
IO-Link Manufacturer Declaration | CERT-4527 | 318 KB |
Device type managers | Release Info | File Type | File Size |
---|---|---|---|
DTM for OMT/OQT R20x series / DTM für OMT/OQT R20x Serie | V1.0.0.1 / 2019-08-23 | ZIP | 8412 KB |
IO Device Description (IODD) | |||
IODD for OMT-R200 series / IODD für OMT-R200 Serie | V1.00.002 / 2019-03-30 | ZIP | 808 KB |
Software Tools | |||
IO-Link Offline Parameterization Tool / IO-Link Offline-Parametriertool | V1.00.004 / 2020-06-01 | ZIP | 63827 KB |
Accessories | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
The optical sensors in the series are the first devices to offer an end-to-end solution in a medium-sized standard design – from the thru-beam sensor through to the measuring distance sensor. As a result of this design, the sensors are able to perform practically all standard automation tasks.
The entire series enables sensors to communicate via IO-Link.
The DuraBeam laser sensors are durable and can be used in the same way as a standard sensor.
Multi Pixel Technology (MPT) ensures that the standard sensors are flexible and can be adapted to the application environment.