Serviceline Industrial Sensors
Serviceline Explosion Protection

Resistance Thermometer for Cold Junction Compensation KC-CJC-1BU

KC-CJC-1BU
  • 2-pin
  • For KC modules of K-System
  • Integrated Cold Junction Compensation
  • Packaging unit: 1 piece KC-CJC, 1 piece KC-STP-BU

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  KC-CJC-1BU

Product Description
Resistance thermometer for cold junction compensation for KC modules
Mechanical specifications
Massapprox. 15 g
Dimensions23 x 10 x 17 mm (0.9 x 0.4 x 0.67 inch)

Classifications

SystemClasscode
ECLASS 13.027219090
ECLASS 12.027219090
ECLASS 11.027219290
ECLASS 10.0.127219290
ECLASS 9.027219290
ECLASS 8.027219290
ECLASS 5.127279290
ETIM 9.0EC003015
ETIM 8.0EC003015
ETIM 7.0EC003015
ETIM 6.0EC003015
ETIM 5.0EC003015
UNSPSC 12.139121008

Details: KC-CJC-1BU

Function

The resistance thermometer is suitable for K-System applications.

The resistance thermometer can be used for connection of signals from the hazardous area.

This type Pt100 resistance thermometer is encapsulated in the housing.

Product Documentation: KC-CJC-1BU

Language Selection:
Brief InstructionsLanguageFile TypeFile Size
Brief Instructions - OHV100-F222 / Kurzanleitung - OHV100-F222ALLPDF354 KB

Associated Products: KC-CJC-1BU

Accessory of

1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 12.5 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 19 ... 30 V DC, Type: 2-wire connection, Type [2]: 3-wire connection, Type [3]: 4-wire connectionpa
1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 12.5 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 19 ... 30 V DC, Type: 2-wire connection, Type [2]: 3-wire connection, Type [3]: 4-wire connectionpa
Safety Products Selector

Choose from various selection criteria like safety integrity level, performance level, device function, and signal type and find the SIL/PL assessed device that you are looking for.