IPH-FP-C1D1
  • Explosion-proof housing
  • Connection via screw terminals
  • Approved for Class I, Groups C, D

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH, also apply to Pepperl+Fuchs AG.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  IPH-FP-C1D1

Product Description
LF read/write head, for IDENTControl, for hazardous areas
General specifications
Operating frequency125 kHz
Transfer rate2 kBit/s
Sensing range
Read distance0 ... 52 mm
Write distance0 ... 43 mm
Widthmax. 62 mm
UL File NumberE305142
Functional safety related parameters
MTTFd710 a
Mission Time (TM)10 a
Diagnostic Coverage (DC)0 %
Indicators/operating means
LED green/yellowgreen: power on
green flashing: read/write attempt performed
yellow: data carrier detected
Electrical specifications
Power consumption≤ 1.2 W
Supplyfrom the IDENTControl
Compliance with standards and directives
Directive conformity
R&TTE Directive 1995/5/ECEN 301489-1 V1.8.1 (2008-04), EN 301489-3 V1.4.1 (2002-08), EN 300330-2 V1.3.1 (2006-04), EN 60950-1:2006
Standard conformity
Electromagnetic compatibilityEN 61326
Degree of protectionEN 60529
Approvals and certificates
UL approvalClass I, Division 1, Groups C, D
FCC approvalThis device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation.
Caution:
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Degree of protectionNEMA Type 4, 7, 9
ConnectionTerminals
Material
Housingdiecast aluminum
Basediecast aluminum
Installation
Distance between two headsMultiplex on: ≥ 65 mm
Multiplex off: ≥ 515 mm
Massapprox. 4080 g

CAD+CAE: IPH-FP-C1D1

CADFile TypeFile Size
Dimension drawing 2-D (DWG) / Abmessungszeichnung 2-D (DWG)ZIP1024 KB

Associated Products: IPH-FP-C1D1

Accessories

Data carrierfa

Data carrierfa

Code carrierfa
Code carrier, ISO check cardfa
Data carrierfa
Visit the RFID Hub

Visit our "RFID Hub"—this special website is a knowledge base for RFID. Get answers on frequently asked questions and learn about typical RFID applications …