Serviceline Industrial Sensors
Serviceline Explosion Protection

Read/write station IQT1-FP-IO-V1

IQT1-FP-IO-V1
  • Operating frequency 13.56 MHz
  • IO-link interface
  • Conforms to ISO 15693
  • Suitable for FRAM transponder
  • LEDs as function indicators
  • Connection via V1 (M12 x 1) plug connection
  • Degree of protection IP67
  • For connection to IO-Link master

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  IQT1-FP-IO-V1

Product Description
HF read/write station with IO-Link in accordance with ISO 15693
General specifications
Operating frequency13.56 MHz
Transfer rate26 kBit/s
Sensing range
Read distance0 ... 130 mm
Write distance0 ... 130 mm
Widthmax. 100 mm
UL File NumberE87056
Functional safety related parameters
MTTFd280 a
Mission Time (TM)10 a
Diagnostic Coverage (DC)0 %
Indicators/operating means
LED red/greenGreen: power on
Flashing green: IO-Link communication
Flashing red/green: IO-Link communication interrupted
LED blue/yellowBlue: Write/read attempt performed
Yellow: Read/write tag detected
Electrical specifications
Rated operating voltage20 ... 30 V DC , ripple 10 %SS
Power consumption≤ 2 W
Interface
Interface typeIO-Link
ProtocolIO-Link V1.1
Cycle timemin. 4 ms
ModeCOM 3 (230.4 kBaud)
Process data width32 Byte
SIO mode supportno
Directive conformity
Radio equipment
Directive 2014/53/EUEN 301489-1
EN 301489-3
EN 300330
EN 62368-1
EN 50364
RoHS
Directive 2011/65/EU (RoHS)EN 50581
Standard conformity
Degree of protectionEN 60529
Communication interfaceEN 61131-9
RFIDISO/IEC 15693-2
ISO/IEC 15693-3
ISO/IEC 18000-3
Approvals and certificates
UL approvalcULus Listed, Class 2 Power Source, Type 1 enclosure
FCC approvalThis device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation.
Caution:
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
IC approvalThis device complies with Industry Canada licence-exempt RSS standard(s) and with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device.

Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
Radio approvalUSA: FCC IREIQT1FPIO
Canada: 7037A-IQT1FPIO
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Degree of protectionIP67
Connectionconnector M12 x 1
Material
HousingPBT
Basediecast aluminum
Encapsulation compoundCY 221/HY 2966
Installation
Distance between two heads≥ 150 mm
Massapprox. 380 g

CAD+CAE: IQT1-FP-IO-V1

CADFile TypeFile Size
3-D model in IGS format / 3-D-Modell im IGS-FormatIGS4298 KB
3-D model in STP format / 3-D-Modell im STP-FormatSTP1576 KB

Approvals+Certificates: IQT1-FP-IO-V1

Statements of complianceCertificate No.File TypeFile Size
EU-Declaration of conformity / EU-KonformitätserklärungDOC-3819APDF161 KB
Certificates
Canada CETECOM ICT Radio Approval7037A-IQT1FPIOPDF1829 KB
EAC???? N RU ?-DE.??01.?.02192/19PDF652 KB
IO-Link Manufacturer DeclarationCERT-4469PDF160 KB
USA CETECOM ICT FCC ApprovalIREIQT1FPIOPDF127 KB

Software: IQT1-FP-IO-V1

IO Device Description (IODD)Release InfoFile TypeFile Size
IODD for IQT1 series / IODD für IQT1-Serie1.01.000 / 2018-02-22ZIP239 KB
Software Tools
IO-Link Offline Parameterization Tool / IO-Link Offline-ParametriertoolV1.00.004 / 2020-06-01ZIP63827 KB

Associated Products: IQT1-FP-IO-V1

Accessories

Connecting cable, M12 to M12, PVC cable 4-pinfa

Connecting cable, M12 to M12, PVC cable 4-pinfa

Data carrierfa

Data carrierfa

Data carrierfa

Data carrierfa

Data carrierfa

Data carrierfa

Data carrierfa

Data carrierfa
Ethernet IO-Link module with 8 inputs/outputsfa
IO-Link master, supply via USB port or separate power supply, LED indicators, M12 plug for sensor connectionfa
Connecting cable, M12 to M12, PVC cable 4-pinfa
Data carrierfa
Data carrierfa
Visit the RFID Hub