Serviceline Industrial Sensors
Serviceline Explosion Protection

Read/write head hazardous area IQH1-FP-V1-Ex GUBW1

IQH1-FP-V1-Ex GUBW1
  • Read/Write Head for Hazardous Areas
  • Flameproof enclosure
  • ATEX-approval for zone 1 and zone 21
  • For connection to IDENTControl control interface

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  IQH1-FP-V1-Ex GUBW1

Product Description
HF read/write head, ISO 15693, for IDENTControl, hazardous areas
General specifications
Operating frequency13.56 MHz
Transfer rate26 kBit/s
Operating distancetyp. 40 mm
Indicators/operating means
LED green/yellowgreen: power on
green flashing: read/write attempt performed
yellow: data carrier detected
Electrical specifications
Power consumption≤ 1.3 W
Supplyfrom the IDENTControl
Directive conformity
Radio equipment
Directive 2014/53/EUEN 301489-1
EN 301489-3
EN 300330
EN 62368-1
EN 50364
RoHS
Directive 2011/65/EU (RoHS)EN 50581
Standard conformity
Degree of protectionEN 60529
RFIDISO/IEC 15693-2
ISO/IEC 15693-3
ISO/IEC 18000-3
Approvals and certificates
IECEx approvalIECEx INE 14.0042X
ATEX approvalINERIS 14 ATEX 0035X
Device type: GUBW1.D.CP-IQH1-FP-V1
Device number: 70117532
MarkingEx-Hexagon II 2 GD
Ex db IIC T6 Gb
Ex tb IIIC T85°C Db
Ambient conditions
Ambient temperature-25 ... 55 °C (-13 ... 131 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Degree of protectionIP66
ConnectionTerminal block with screw connection
Max. clamping range 0.13 mm² ... 2.5 mm² M20 barrier gland for unarmored cables, clamping range 3 mm ... 8.5 mm
Material
HousingSeawater-resistant aluminum
Installation
Distance between two headsMultiplex on: ≥ 155 mm
Multiplex off: ≥ 350 mm
Massapprox. 6900 g
Equipment protection level Gb
CE marking[*PD-Z20124A*]
ATEX markingEx-Hexagon II 2 GD Ex db IIC T6 Gb
Directive conformity2014/34/EU
StandardsEN 60079-0:2012+A11:2013, EN 60079-1:2014, EN 61241-0:2006, EN 61241-1:2004
Flameproof enclosure ignition protection class
Use is restricted to the following stated conditions

Documents: IQH1-FP-V1-Ex GUBW1

ManualsLanguageFile TypeFile Size
Manual Read / Write Ranges and Passing Speeds RFIDENGPDF3640 KB
Handbuch Schreib- und Leseabstände und Vorbeifahrgeschwindigkeiten RFIDGERPDF3642 KB
Short instructions, safety information
Brief Instructions GUB* / GUBX*ENGPDF930 KB
Kurzanleitung GUB* / GUBX*GERPDF898 KB
Brief Instructions GUB* / GUBX*RUSPDF1151 KB

Approvals+Certificates: IQH1-FP-V1-Ex GUBW1

Statements of complianceCertificate No.File TypeFile Size
EU-Declaration of conformity / EU-KonformitätserklärungDOC-4760PDF99 KB
Certificates
Europe INERIS ATEXINERIS 14 ATEX 0035XPDF5709 KB
Worldwide INERIS IECEx Certificate of ConformityIECEx INE 14.0042XLINK---

Associated Products: IQH1-FP-V1-Ex GUBW1

Accessories

Control interface unit IDENTControl with PROFIBUS DP interfacefa

IDENTControl control interface with Ethernet interface for TCP/IP, PROFINET, EtherNet/IP, and MODBUS TCP protocolsfa

Control interface unit IDENTControl Compactwith serial interface RS-232 and RS-485fa

Control interface unit IDENTControl Compact with interface for PROFIBUS DPfa

IDENTControl Compact control interface with Ethernet interface for TCP/IP, PROFINET, EtherNet/IP, and MODBUS TCP protocolsfa

Control interface unit IDENTControl Compact with EtherCAT interfacefa

Data carrierfa

Data carrierfa

Data carrierfa

Data carrierfa

Data carrierfa

Data carrierfa

Data carrierfa

Data carrierfa
Data carrierfa
Data carrier for hazardous areafa
Visit the RFID Hub

Visit our "RFID Hub"—this special website is a knowledge base for RFID. Get answers on frequently asked questions and learn about typical RFID applications …