Product |
|
|
The product 'PSE2-SC-02' is now added to your watch list.
The product 'PSE2-SC-02' is already on your watch list.
|
Safety control unit, For evaluating safety thru-beam sensors PSE4-SL, Safety category 3 according to EN61496-1, 24 V DC supply voltage, 1 safe output contact, Performance level PLd (EN13849-1) is attainable, Component of PSE4 modular system, Operating voltage: 24 V DC +20/-10 % 24 V AC ± 10 %, Number of channels: 4-channelfa |
|
|
|
The product 'PSE4-SC-01' is now added to your watch list.
The product 'PSE4-SC-01' is already on your watch list.
|
Safety control unit, For evaluating safety thru-beam sensors PSE4-SL, Safety category 4 according to EN61496-1, 24 V DC supply voltage, 2 safe output contacts, Performance level PLe (EN13849-1) is attainable, Component of PSE4 modular system, Operating voltage: 24 V DC +20/-10 %, Number of channels: 1-channelfa |
|
|
|
The product 'SB4 Cape' is now added to your watch list.
The product 'SB4 Cape' is already on your watch list.
|
cover sheetfa |
|
|
|
The product 'SB4 Housing 4' is now added to your watch list.
The product 'SB4 Housing 4' is already on your watch list.
|
Empty housing for Evaluation unit SB4fa |
|
|
|
The product 'SB4 Housing 5' is now added to your watch list.
The product 'SB4 Housing 5' is already on your watch list.
|
Empty housing for Evaluation unit SB4fa |
|
|
|
The product 'SB4 Module 2E' is now added to your watch list.
The product 'SB4 Module 2E' is already on your watch list.
|
OSSD-R/E-stop-module, Safety outputs OSSD, external status displays OSSD, 2 sensor channels, Operating mode can be selected by means of DIP switches, Start/Restart disable , Relay monitor, Stop function Cat.0 or Cat.1 and central stop function Cat.0, Time function, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 24 V DC ± 20 % , 24 V DC ± 20 % , via SB4 Housingfa |
|
|
|
The product 'SB4 Module 4C' is now added to your watch list.
The product 'SB4 Module 4C' is already on your watch list.
|
Sensor module, 4 sensor channels, Single module for safety thru-beam sensors SLA12 and SLA29 and for 2 channel safety devices (emergency off), Operating mode can be selected by means of DIP switches, Screw terminals or spring terminals, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 24 V DC ± 20 % , via SB4 Housingfa |
|
|
|
The product 'SB4 Module 4CP' is now added to your watch list.
The product 'SB4 Module 4CP' is already on your watch list.
|
Sensor module, 4 sensor channels, Single module for safety thru-beam sensors SLA12 and SLA29 and for 2 channel safety devices (emergency off), Micro-Controller controls, Operating mode can be selected by means of DIP switches, Screw terminals or spring terminals, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 24 V DC ± 20 % , via SB4 Housingfa |
|
|
|
The product 'SB4 Module 4M' is now added to your watch list.
The product 'SB4 Module 4M' is already on your watch list.
|
Muting module, 4 sensor channels, Double muting, Emergency muting for the correction of the material jam, Operating mode can be selected by means of DIP switches, Screw terminals or spring terminals, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 24 V DC ± 20 % , 24 V DC ± 20 % , via SB4 Housingfa |
|
|
|
The product 'SB4 Module 4XP' is now added to your watch list.
The product 'SB4 Module 4XP' is already on your watch list.
|
Sensor module, 4 sensor channels, Micro-Controller controls, Operating mode can be selected by means of DIP switches, Individual module for SLA5(S), SLA20, SLA25, SLA28 and SLA40 security through-beam sensors; for SLP safety light grids, for SLC safety light curtains; for switching pads and emergency stop buttons of categories 2 or 4, Screw terminals or spring terminals, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4fa |
|
|
|   |