Product |
|
|
The product 'PSE2-SC-02' is now added to your watch list.
The product 'PSE2-SC-02' is already on your watch list.
|
Safety control unit, For evaluating safety thru-beam sensors PSE4-SL, Safety category 3 according to EN61496-1, 24 V DC supply voltage, 1 safe output contact, Performance level PLd (EN13849-1) is attainable, Component of PSE4 modular system, Operating voltage: 24 V DC +20/-10 % 24 V AC ± 10 %, Number of channels: 4-channelfa |
|
|
|
The product 'PSE4-SC-01' is now added to your watch list.
The product 'PSE4-SC-01' is already on your watch list.
|
Safety control unit, For evaluating safety thru-beam sensors PSE4-SL, Safety category 4 according to EN61496-1, 24 V DC supply voltage, 2 safe output contacts, Performance level PLe (EN13849-1) is attainable, Component of PSE4 modular system, Operating voltage: 24 V DC +20/-10 %, Number of channels: 1-channelfa |
|
|
|
The product 'SB4 Cape' is now added to your watch list.
The product 'SB4 Cape' is already on your watch list.
|
cover sheetfa |
|
|
|
The product 'SB4 Housing 2' is now added to your watch list.
The product 'SB4 Housing 2' is already on your watch list.
|
Empty housing for Evaluation unit SB4fa |
|
|
|
The product 'SB4 Housing 3' is now added to your watch list.
The product 'SB4 Housing 3' is already on your watch list.
|
Empty housing for Evaluation unit SB4fa |
|
|
|
The product 'SB4 Housing 4' is now added to your watch list.
The product 'SB4 Housing 4' is already on your watch list.
|
Empty housing for Evaluation unit SB4fa |
|
|
|
The product 'SB4 Housing 5' is now added to your watch list.
The product 'SB4 Housing 5' is already on your watch list.
|
Empty housing for Evaluation unit SB4fa |
|
|
|
The product 'SB4 Housing 6' is now added to your watch list.
The product 'SB4 Housing 6' is already on your watch list.
|
Empty housing for Evaluation unit SB4fa |
|
|
|
The product 'SB4 Module 2E' is now added to your watch list.
The product 'SB4 Module 2E' is already on your watch list.
|
OSSD-R/E-stop-module, Safety outputs OSSD, external status displays OSSD, 2 sensor channels, Operating mode can be selected by means of DIP switches, Start/Restart disable , Relay monitor, Stop function Cat.0 or Cat.1 and central stop function Cat.0, Time function, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 24 V DC ± 20 % , 24 V DC ± 20 % , via SB4 Housingfa |
|
|
|
The product 'SB4 Module 4C' is now added to your watch list.
The product 'SB4 Module 4C' is already on your watch list.
|
Sensor module, 4 sensor channels, Single module for safety thru-beam sensors SLA12 and SLA29 and for 2 channel safety devices (emergency off), Operating mode can be selected by means of DIP switches, Screw terminals or spring terminals, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 24 V DC ± 20 % , via SB4 Housingfa |
|
|
|   |