Datasheet excerpt: Technical data of
GA18/GK18/59/115/161
Product Description |
Thru-beam sensor, M18 threaded housing design, plastic housing, front optical face, 20 m detection range, red light, dark on, AC/DC version, NPN-FET output, fixed cable |
System components |
Emitter | GA18/115 |
Receiver | GK18/59/115/161 |
General specifications |
Effective detection range | 0 ... 20 m |
Threshold detection range | 25 m |
Light source | LED |
Light type | modulated visible red light , 640 nm |
Diameter of the light spot | approx. 1000 mm at 25 m |
Angle of divergence | approx. 3 ° |
Optical face | frontal |
Ambient light limit | 30000 Lux |
Accessories provided | Mounting aids |
Indicators/operating means |
Operation indicator | LED green, statically lit Power on |
Function indicator | Receiver: LED yellow, lights up when light beam is free, flashes when falling short of the stability control ; OFF when light beam is interrupted |
Electrical specifications |
Operating voltage | 20 ... 250 V AC/DC |
No-load supply current | < 2.5 mA per device |
Output |
Switching type | dark on |
Signal output | N-channel MOSFET, short circuit protected |
Switching voltage | max. 250 V AC/DC |
Switching current | max. 200 mA |
Voltage drop | ≤ 3.5 V AC/DC |
Switching frequency | 50 Hz |
Response time | ≤ 10 ms |
Conformity |
Product standard | EN 60947-5-2 |
Compliance with standards and directives |
Standard conformity | |
| Standards | UL 508 |
Approvals and certificates |
EAC conformity | TR CU 020/2011 TR CU 004/2011 |
Protection class | II, rated insulation voltage ≤ 250 V AC with pollution degree 1-2 according to IEC 60664-1 |
UL approval | cULus Listed, Type 1 enclosure For overcurrent protection, install a fuse with a rated current of max. 3 A 250 V AC/DC |
CCC approval | Certified by China Compulsory Certification (CCC) |
Ambient conditions |
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
Storage temperature | -40 ... 70 °C (-40 ... 158 °F) |
Mechanical specifications |
Degree of protection | IP67 |
Connection | 2 m fixed cable |
Material | |
| Housing | ABS / PBT |
| Optical face | PMMA |
Mass | approx. 80 g per device |
Documents:
GA18/GK18/59/115/161
CAD+CAE:
GA18/GK18/59/115/161
Approvals+Certificates:
GA18/GK18/59/115/161
Associated Products:
GA18/GK18/59/115/161
Accessories |
|
|
|
Mounting flange, 18 mmfa |
|
|
|
|
Universal mounting bracket for cylindrical sensors with a diameter of 5 ... 30 mmfa |
|
|
|
|
Mounting Bracket with swivel nutfa |
|
|
|
|
Plastic mounting adapter, 18 mmfa |
|
Function:
GA18/GK18/59/115/161
The GLV/GLK18 series sensors help improve the efficiency of machines and systems. The design of the M18 plastic housing, the connection technology, and sensor properties are highly standardized. Concentrating on the key sensor requirements has produced a robust and reliable product series for DC and AC/DC voltage systems without any over-engineering. The mounting set included in the scope of delivery and the optimized potentiometer design ensure fast assembly and easy configuration.