AS-Interface power supply VAN-115/230AC-K16

VAN-115/230AC-K16
  • AS-Interface certificate
  • PELV/SELV
  • LED operating display
  • 8 A output load
  • 115 V AC / 230 V AC switchable
  • AS-Interface data decoupling
  • Overload protection using FUSE mode

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  VAN-115/230AC-K16

Product Description
AS-Interface power supply, data decoupling, 8 A
General specifications
UL File NumberE223176
MTBF100 a
Indicators/operating means
Reset push-button switchFUSE mode reset
Power selection switchchangeover switch for 115 V AC/230 V AC
LED Overloadred LED, flashes in the FUSE mode
LED IR onred LED:
ON: Plug-in jumper position 2-3
OFF: Plug-in jumper position 1-2
Plug-in jumperPosition 1-2: Communication Mode
Position 2-3: IR addressing
LED AS-i okoperating display; LED green
Electrical specifications
FusingT8A/250 V AC HBC (not accessible)
Capacity factor> 0.5
Rated operating voltagenominal: 100 ... 120 V AC/220 ... 240 V AC (front end selectable)
permissible: 85 ... 132 V AC/184 ... 264 V AC/230 ... 375 V DC
Rated operating current6,0 A (Switch position 115 V)
2.8 A (Switch position 230 V)
Supply frequency47 ... 63 Hz or DC
Efficiencytyp. 92 % (at 230 V AC/8 A)
Surge protectionlimited to max. 55 V
Output
Short-circuit protection/overloadFUSE Mode (2 ... 5 s current, then trips)
Current limit> 8.4 A
Voltage30.55 V DC ± 3 %
Current8 A
Galvanic isolationovervoltage category III
Residual ripple≤ 50 mVss (500 kHz bandwidth, 50-Ω-measurement with ohmic load)
Short-circuit current12 ... 25 A (max. 5 s)
Standard conformity
Electromagnetic compatibilityemitted interference in accordance with EN 50081-2 class B (EN 55011, EN 55022)
noise immunity in accordance with EN 61000-6-2, EN 61000-4-2 to EN 61000-4-6, EN 61000-4-11
Ambient conditions
Ambient temperature-10 ... 70 °C (14 ... 158 °F) (Measured 25 mm below the device)
from 60° C 6W/°C power recovery necessary
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Pollution degree2
Mechanical specifications
Degree of protectionIP20 according to EN 60529
Protection class1 (IEC 60536); Protective conductor connection necessary
ConnectionConnection terminals, max. conductor cross-section
flexible: 0.5 ... 4 mm2
fixed: 0.5 ... 6 mm2
stripped length 7 mm, connector sleeves are permissible
Material
Housingmetal
Massapprox. 890 g
Dimensions
Height124 mm
Width91 mm
Length102 mm

Classifications

SystemClasscode
ECLASS 13.027040301
ECLASS 12.027040301
ECLASS 11.027040301
ECLASS 10.0.127040301
ECLASS 9.027040301
ECLASS 8.027040301
ECLASS 5.127040301
ETIM 9.0EC002540
ETIM 8.0EC002540
ETIM 7.0EC002540
ETIM 6.0EC002540
ETIM 5.0EC002540
UNSPSC 12.139121004

Details: VAN-115/230AC-K16

Function

The primary pulsed DIN rail power pack is used for special power supply of AS-Interface networks via a two-wire line. It supplies a fully loaded AS-Interface system with an output current of 8 A.

The voltage input range of the device can be selected on the front side. This makes it possible to operate the device on all single-phase power supply voltages commonly used worldwide.

Certification of the device according to international and various national standards allows for worldwide usage.

Safe operation using FUSE mode:

To protect against overload and excess temperature, the device has a FUSE mode (electronically simulated fuse), for permanent shutoff of the output in the event of failure. This turns off the device in the event of overload, short circuit or excess temperature, thus protecting the AS-Interface cable and the attached components. A flashing LED indicates that the FUSE mode has been triggered. Turning the device on again requires deliberately pressing a Reset button on the front side of the unit. This prevents unwanted startup from occurring.

Operation without the AS-Interface string:

This AS-Interface power pack has an inductive output. For operation without the AS-Interface string (for example lab measurements) we recommend connecting a 470 μF/35 V capacitor between AS-Interface + and AS-Interface -. Standard commercial laboratory loads frequently tend to oscillate and together with the data decoupling form a resonance that exceeds the permitted modulation voltage.

Product Documentation: VAN-115/230AC-K16

Language Selection:
Brief InstructionsLanguageFile TypeFile Size
Instruction leaflet / BeipackzettelALLPDF181 KB
Manual / HandbuchALLPDF86 KB

Design / Simulation: VAN-115/230AC-K16

Language Selection:
CADLanguageFile TypeFile Size
CAD 3-D / CAD 3-DALLSTP10419 KB
CAD Portal / CAD PortalALLLINK---
CAE
CAE EPLAN Data Portal / CAE EPLAN Data PortalALLLINK---
CAE EPLAN macro EDZ / CAE EPLAN Makro EDZALLEDZ40 KB

Approvals: VAN-115/230AC-K16

Language Selection:
CertificatesCertificate No.LanguageFile TypeFile Size
US CA ULCoC E223176 RptRef E223176-20070416ALLPDF444 KB
US CA ULE223176ALLLINK---
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-4814AALLPDF163 KB

Associated Products: VAN-115/230AC-K16

Accessories
AS-Interface Power supply and network checking utilityfa