1-channel signal conditioner, 24 V DC supply, Logic input 19 V DC ... 26.4 V DC, Recommended connectable voltage 8 V DC ... 60 V DC, Relay contact output for energized to safe function , Line fault transparency (LFT), Diagnostic function, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Diagnostics function, Line fault transparency, ETS function (energized to safe), Safety Integrity Level (SIL): SIL 3, Systematic capability (SC): SC 3, Rated voltage: 19 ... 26.4 V DCpa
1-channel signal conditioner, 24 V DC supply, Logic input 19 V DC ... 26.4 V DC, Recommended connectable voltage 50 V AC ... 230 V AC, 60 V DC ... 110 V DC, Relay contact output for energized to safe function , Line fault transparency (LFT), Diagnostic function, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Diagnostics function, Line fault transparency, ETS function (energized to safe), Safety Integrity Level (SIL): SIL 3, Systematic capability (SC): SC 3pa
1-channel signal conditioner, 24 V DC supply, Logic input 20.5 V DC ... 26.4 V DC, Recommended connectable voltage 50 V AC ... 230 V AC, 60 V DC ... 110 V DC, Relay contact output for energized to safe function , Line fault transparency (LFT), Diagnostic function, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Diagnostics function, Line fault transparency, ETS function (energized to safe), Safety Integrity Level (SIL): SIL 3, Systematic capability (SC): SC 3pa
Advanced Diagnostic Module, Kit for Stand-Alone Operation
Comprehensive diagnostics for the fieldbus physical layer, Module and motherboard for retrofit of any installation, Precise measurements through passive circuits, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Europe, USA, Canada, Device coupler location: non-explosion hazardous area Zone 2 - high-power trunk Zone 1 - high-power trunk Division 2 - high-power trunk Division 1 - high-power trunkpa
Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface
System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, Simple automatic setup of Advanced Diagnostics, Common alarm handling, For FOUNDATION Fieldbus and PROFIBUS PA, International, Europepa
Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O
System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, Simple automatic setup of Advanced Diagnostics, Alarm handling and integrated I/O for cabinet monitoring/control, For FOUNDATION Fieldbus and PROFIBUS PA, International, Europe, Device coupler location: non-explosion hazardous area Zone 2 - high-power trunk Zone 1 - high-power trunk Division 2 - high-power trunk Division 1 - high-power trunkpa
Dispositivo Bluetooth compatto, semplice da usare, Generazione di un rapporto di installazione completo in caso di approvazione del sito, Controlli delle prestazioni su loop e installazione, Compatibile con tutti i loop detector LC20, Gamma operativa fino a 17 mfa
Magnetic, non Contact, Clear function verification via two-color LEDs (red/green), Simple installation and adjustment using assistance functions reduce costs, Self-diagnostics including the magnetic wheel provide quality assurance, Internal intelligence provides easy setup and reliable operation , The elastomer coating of the magnetic wheel provides resistance to dirt as well as thermal and mechanical shock, Enclosure type: Rectangular type, Type of shaft: non-contactfa
Analisi per barriere fotoelettriche dirette di sicurezza SLA12 e SLA29 e per sistemi di sicurezza a doppio canale (arresto di emergenza), Slot per unità di controllo SB4 per funzionalità opzionale migliorata, Con autosorveglianza (tipo 4 a norme IEC/EN 61496-1), Modi operativi selezionabili mediante DIP switch, Indicatore diagnostico a 7 segmenti, Uscite di sicurezza OSSD, indicatori di stato esterni OSSD, Livello d'integrazione sicurezza (SIL): SIL 3, Livello di performance (PL): PL e, Categoria: 4fa
Non disponibile per l'acquisto: Comprehensive diagnostics for the fieldbus physical layer, Mobile kit for the fieldbus professional, Precise measurements through passive circuits, For commissioning and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Europe, Device coupler location: non-explosion hazardous area Zone 2 - high-power trunk Division 2 - high-power trunk Division 1 - high-power trunk, Device coupler location [2]: Zone 2 - high-power trunk, Device coupler location [4]: Division 2 - high-power trunkpa
Non disponibile per l'acquisto: Software user interface for Advanced Diagnostic Modules, Access to mobile ADM via USB-port, Embedded expert system gives pointed advice in clear text, Includes Commissioning Wizard, data historian, oscilloscope..., For FOUNDATION Fieldbus H1 and PROFIBUS PApa
Non disponibile per l'acquisto: System integration kit for Advanced Diagnostics, PCS integration via Ethernet, Simple automatic setup of Advanced Diagnostics, Common alarm handling, For FOUNDATION Fieldbus and PROFIBUS PApa
Non disponibile per l'acquisto: Magnetic, Non Contact, Clear function verification via two-color LEDs (red/green), Simple installation and adjustment using assistance functions reduce costs, Self-diagnostics including the magnetic wheel provide quality assurance, Internal intelligence provides easy setup and reliable operation , The elastomer coating of the magnetic wheel provides resistance to dirt as well as thermal and mechanical shock, Output type: push-pull, incrementalfa
Non disponibile per l'acquisto: Analisi per barriere fotoelettriche dirette di sicurezza SLA12 e SLA29, Con autosorveglianza (tipo 4 a norme IEC/EN 61496-1), Modi operativi selezionabili mediante DIP switch, Interdizione di avviamento/riavviamento , Monitor relè, Indicazione riserva operativa, Indicatore delle funzioni ben visibile, Indicatore diagnostico a 7 segmenti, Livello d'integrazione sicurezza (SIL): SIL 3, Livello di performance (PL): PL e, Categoria: 4, Tensione di esercizio: 24 V DC, -15 %/+20 %fa
Griglia optoelettronica di sicurezza con un'unità di analisi integrata
Non disponibile per l'acquisto: Distanza utile fino a 20 m, Esecuzione a 2-, 3-, e 4 raggi, Distanza raggi 300, 400 e 500 mm, Con autosorveglianza (tipo 4 a norme IEC/EN 61496-1), Interdizione di avviamento/riavviamento , Grado di protezione IP67, Indicatore diagnostico a 7 segmenti, Indicazione riserva operativa, Modo operativo: A scelta con o senza interdizione di avviamento/riavviamento, Livello d'integrazione sicurezza (SIL): SIL 3, Livello di performance (PL): PL efa
Griglia optoelettronica di sicurezza con un'unità di analisi integrata
Non disponibile per l'acquisto: Distanza utile fino a 20 m, Esecuzione a 2-, 3-, e 4 raggi, Distanza raggi 300, 400 e 500 mm, Con autosorveglianza (tipo 4 a norme IEC/EN 61496-1), Grado di protezione IP67, Indicatore diagnostico a 7 segmenti, Indicazione riserva operativa, Attacco mediante connettore M12 x b1, Modo operativo: A scelta con o senza interdizione di avviamento/riavviamento, Livello d'integrazione sicurezza (SIL): SIL 3, Livello di performance (PL): PL efa
Non disponibile per l'acquisto: Omologazione ATEX per la zona 2 e la zona 22, Distanza del fascio di 500 mm, Con autosorveglianza (tipo 4 a norme IEC/EN 61496-1), Uscite di sicurezza OSSD, indicatori di stato esterni OSSD, Interdizione di avviamento/riavviamento , Indicatore diagnostico a 7 segmenti, Indicazione riserva operativa, Grado di protezione IP66, Modo operativo: A scelta con o senza interdizione di avviamento/riavviamento, Livello d'integrazione sicurezza (SIL): SIL 3, Livello di performance (PL): PL efa
Griglia optoelettronica di sicurezza con un'unità di analisi integrata
Non disponibile per l'acquisto: Distanza utile fino a 20 m, Esecuzione a 2-, 3-, e 4 raggi, Distanza raggi 300, 400 e 500 mm, Con autosorveglianza (tipo 4 a norme IEC/EN 61496-1), Interdizione di avviamento/riavviamento , Grado di protezione IP67, Indicatore diagnostico a 7 segmenti, Indicazione riserva operativa, Modo operativo: A scelta con o senza interdizione di avviamento/riavviamento, Livello d'integrazione sicurezza (SIL): SIL 3, Livello di performance (PL): PL efa
Griglia optoelettronica di sicurezza con un'unità di analisi integrata
Non disponibile per l'acquisto: Distanza utile fino a 20 m, Esecuzione a 2-, 3-, e 4 raggi, Distanza raggi 300, 400 e 500 mm, Con autosorveglianza (tipo 4 a norme IEC/EN 61496-1), Interdizione di avviamento/riavviamento , Grado di protezione IP67, Indicatore diagnostico a 7 segmenti, Indicazione riserva operativa, Modo operativo: A scelta con o senza interdizione di avviamento/riavviamento, Livello d'integrazione sicurezza (SIL): SIL 3, Livello di performance (PL): PL e, Uscita di sicurezza: 2 uscite a relè, contatti NO forzatifa
1-10/76Elementi per pagina:
Nessun risultato trovato?
Suggerimento: usa il carattere * prima del tuo termine di ricerca, modifica la tua ricerca, verificare i termini di ricerca per gli errori ortografici, contattaci per le tue specifiche richieste.