Single head system, Analog output 4 mA ... 20 mA, Extremely small unusable area, TEACH-IN, Series: -F42, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 analog output 4 ... 20 mA, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 5-pin, Housing: ABSfa
Single head system, Switching output, 5 different output functions can be set, Program input, Series: -F54, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 switch output E5, PNP, NO/NC, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 5-pin, Housing: ABSfa
Non disponibile per l'acquisto: Single head system, Separate evaluation, With temperature sensor, Direct detection mode, Series: VariKont®, Operating voltage: 20 ... 30 V DC , ripple 10 %SS, Output type: 1 pulse output for temperature 1-level: > 4 V (100 µA), 0-level: < 0.5 V (100 µA) 1 pulse output for echo propagation time 1-level: ≥ UB -3 V (< 10 mA), 0-level: ≤ 1 V (100 µA), UL approval: cULus Listed, General Purposefa
Non disponibile per l'acquisto: Single head system, Serial digital output, 3 different output options can be programmed, Paramaterization input, Series: -18GM, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 serial output, push/pull, programmable, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 5-pin, Housing: brass, nickel-platedfa
Non disponibile per l'acquisto: Single head system, 2 switch outputs, Program input, Temperature compensation, Series: -18GM, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 2 switch outputs NPN, NO/NC, programmable, Connection: 5-pin V15 (M12 x 1) connector, Housing: brass, nickel-platedfa
Non disponibile per l'acquisto: Single head system, Switch output, 5 different output functions can be set, Program input, Series: -18GM, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 switching output E4, NPN, NO/NC, programmable, Connection: 5-pin V15 (M12 x 1) connector, Housing: brass, nickel-platedfa
Non disponibile per l'acquisto: Single head system, Switch output, 5 different output functions can be set, Program input, Series: -18GM, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 switching output E5, PNP NO/NC, programmable, Connection type: Connector plug M12 x 1 , 5-pin, Housing: brass, nickel-platedfa
Non disponibile per l'acquisto: Single head system, Switching output, 5 different output functions can be set, Selectable sound lobe width, Series: -18GM, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 switching output E5, PNP NO/NC, programmable, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 5-pin, Housing: brass, nickel-platedfa
Non disponibile per l'acquisto: Single head system, 2 switch outputs, 3 different output functions can be set, Program input, Series: -18GM, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 2 switch outputs PNP, NO/NC, programmable, Connection type: Connector plug M12 x 1 , 5-pin, Housing: brass, nickel-platedfa
Non disponibile per l'acquisto: Single head system, 2 switch outputs, 3 different output functions can be set, Selectable sound lobe width, Series: -18GM, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 2 switch outputs PNP, NO/NC, programmable, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 5-pin, Housing: brass, nickel-platedfa
Non disponibile per l'acquisto: Single head system, 2 switch outputs, 3 different output functions can be set, Program input, Series: -18GM, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 2 switch outputs NPN, NO/NC, programmable, Connection: 5-pin V15 (M12 x 1) connector, Housing: brass, nickel-platedfa
Le attrezzature per girapacchi e movimentazione cataste utilizzano numerosi sensori industriali di Pepperl+Fuchs ... della distanza Soluzione di sensori: UB500-18GM, UB500-F54, UC500-L2, VDM28 Vantaggi per il cliente: Rilevamento preciso della posizione indipendentemente dal colore o dalla finitura del pallet Uscite analogiche e discrete Soluzioni a ultrasuoni e fotoelettriche ...
Le applicazioni di stampa a bobina vengono semplificate grazie ai sensori a ultrasuono o fotoelettrici di Pepperl+Fuchs ... e vibrazioni Immunità al colore dei rulli Uscite analogiche e discrete Soluzioni di fotocellule e sensori a ultrasuono Tensionamento bobina Soluzione di sensori: Misurazione della distanza VDM28, UB500-F54 Vantaggi per il cliente: Garanzia di una tensione ...
I sensori Pepperl+Fuchs trovano impiego nelle macchine fustellatrici ... UB500-18GM, UB500-F54, UC500-L2, VDM28 Vantaggi per il cliente: Rilevamento preciso della posizione indipendentemente dal colore o dalla finitura del pallet Uscite analogiche e discrete Soluzioni a ultrasuoni e fotoelettriche Rilevamento dei fogli doppi ...
Pepperl+Fuchs offre un'ampia varietà di sensori industriali per le applicazioni di stampa a fogli ... stretti assicurano immunità alle interferenze dalle superfici riflettenti Il controller di sicurezza modulare SafeBox collega tutti i componenti di sicurezza in una unità Rilevamento pallet Soluzione di sensori: Misura della distanza UB500-18GM, UB500-F54 ...
Porte automatiche, ascensori, scale mobili, barriere o trasporto pubblico: i sensori della gamma Pepperl+Fuchs sono adatti per un'ampia gamma di applicazioni negli ingressi automatizzati ... di accesso dei tram. A tale scopo, i sensori ad ultrasuoni serie UB500 sono installati nelle pedane ad estensione automatica, in cui misurano la distanza tra pedana e piattaforma. Monitoraggio flessibile del punto cieco Il monitoraggio dei punti ciechi ...