Servizio assistenza Sensori Industriali
Telefono: +39 039 69599 1
Fax.: +39 039 69599 30
Servizio assistenza Protezione contro le esplosioni
Telefono ++39 039 62921
Fax ++39 039 6292 390

RFID evaluation unit IC-KP2-1HRX-2V1

IC-KP2-1HRX-2V1
  • LED status indicator of bus communication and read/write head

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Scarica il Datasheet completo in formato PDF:


Estratto del Datasheet: Dati tecnici del  IC-KP2-1HRX-2V1

Descrizione prodotto
Control interface unit IDENTControl Compactwith serial interface RS-232 and RS-485
General specifications
Number of read/write headsmax. 1
UL File NumberE87056
MTBF80 a (Operation at +40 °C)
Indicators/operating means
LED 1Status indicator for read/write head
green: command at read/write head active
yellow: approx. 1 second long, if command was successfully executed
LED CH1green: read head detected
red: Configuration error
LED PWR/ERRgreen: power on
red: Hardware fault
LED TxDgreen: flashes in rhythm with the transmitted data
LED RxDgreen: flashes in rhythm of receiving data
Electrical specifications
Rated operating voltage20 ... 30 V DC , PELV
Ripple≤ 10 % at 30 V DC
Current consumption≤ 4 A incl. read/write heads
Power consumption2 W Without read/write head
Galvanic isolationbasic insulation acc. to DIN EN 50178, rated insulation voltage of 50 Veff
Interface 1
Interface typeserial
Physical RS-485
ProtocolASCII
Transfer rate1200; 2400; 4800; 9600; 19200; 38400 Bit/s
Interface 2
Interface typeserial
Physical RS 232
ProtocolASCII
Transfer rate1200; 2400; 4800; 9600; 19200; 38400 Bit/s
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61000-6-2
EN 61000-6-4
RoHS
Directive 2011/65/EU (RoHS)IEC/EN 63000
Standard conformity
Degree of protectionIEC 60529
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Climatic conditionsair humidity max. 96 %
Salt spray resistant to EN 60068-2-52
Shock and impact resistanceOscillation (Sine): 5 g, 10 - 1000 Hz to EN 60068-2-6
Shock (Half-sine): 30 g, 11 ms in accordance with EN 60068-2-27
Mechanical specifications
Degree of protectionIP67
Connectionread/write head: M12 plug connection, 4-pin, screened,
Power supply: M12 connector
Protective earth: M4 earthing screw
RS 232: M12 plug connection
RS 485: M12 connector
Material
Housingpowder coated aluminum
Installationscrew fixing
Massapprox. 300 g
Dimensions
Height42 mm
Width62 mm
Length137 mm

Classifications

SystemClasscode
ECLASS 13.027280401
ECLASS 12.027280401
ECLASS 11.027280401
ECLASS 10.0.127280401
ECLASS 9.027280401
ECLASS 8.027280401
ECLASS 5.127280401
ETIM 9.0EC002998
ETIM 8.0EC002998
ETIM 7.0EC002998
ETIM 6.0EC002998
ETIM 5.0EC002998
UNSPSC 12.143211710

Details: IC-KP2-1HRX-2V1

Informative Literature: IC-KP2-1HRX-2V1

Language Selection:
LiteratureLinguaFile tipoDimensioni
Application Report - RFID Systems in Industrial Metal StampingENGPDF1773 KB
Application Report - Safe Assignment of Workpiece and ToolENGPDF204 KB

Product Documentation: IC-KP2-1HRX-2V1

Language Selection:
Brief InstructionsLinguaFile tipoDimensioni
Brief Instructions - IC-KP2-*ENGPDF2285 KB
Manuals
Manual IC-KP2-1HRX-2V1ENGPDF1277 KB
Manual Read / Write Ranges and Passing Speeds RFIDENGPDF3640 KB

Design / Simulation: IC-KP2-1HRX-2V1

Language Selection:
CADLinguaFile tipoDimensioni
CAD 3-D / CAD 3-DALLSTP1536 KB
CAD Portal / CAD PortalALLLINK---

Approvals: IC-KP2-1HRX-2V1

Language Selection:
CertificatesCertificato NumeroLinguaFile tipoDimensioni
Canada, USA ULCoC UL-CA-L87056-31-61115002-0 / UL-US-L87056-11-61115002-0ALLPDF561 KB
Korea Radio ApprovalMSIP-REI-PF1-ICKP21HRX2V1ALLPDF364 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-0687EALLPDF111 KB
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F)DOC-6844ALLPDF108 KB

Software: IC-KP2-1HRX-2V1

Language Selection:
Software Toolsinformazioni sulla liberatoriaFile tipoDimensioni
Software RFIDControl Demo / Software RFIDControl DemoV 1.5.3ZIP5467 KB

Prodotti associati : IC-KP2-1HRX-2V1

Accessory of
UHF read/write head for hazardous areas, for IDENTControl, Canada, USA, and Mexicofa
Accessories

Cordset M12 socket straight to M12 plug angled A-coded, 4-pin, PUR cable grey, shieldedfa

Cordset M12 socket straight to M12 plug angled A-coded, 4-pin, PUR cable grey, shieldedfa

Cordset M12 socket straight to M12 plug angled A-coded, 4-pin, PUR cable grey, shieldedfa

Female cordset single-ended M12 straight A-coded, 4-pin, PUR cable grey, shieldedfa
Adapter cable M12 plug straight A-coded 4-pin to Sub-D-plug straight 9-pin, PUR cable grey, shieldedfa
Mounting aid for DIN railfa
Adapter cable M12 plug straight A-coded 4-pin to Sub-D-socket straight 9-pin, PUR cable grey, shieldedfa
Visita l'hub RFID

Visita il nostro "hub RFID": questo speciale sito Web offre una conoscenza di base per la tecnologia RFID. Qui troverai le risposte nella sezione domande frequenti e informazioni sulle applicazioni RFID più diffuse …