WirelessHART Gateway WHA-GW-F2D2-0-AS-Z2-ETH.EIP

WHA-GW-F2D2-0-AS-Z2-ETH.EIP
  • EtherNet/IP WirelessHART Gateway
  • Graphical network analysis
  • Simple and automatic configuration options
  • Ethernet and RS 485 interface
  • HART protocol via both interfaces
  • EtherNet/IP protocol via Ethernet interface
  • Input WirelessHART wireless interface
  • 24 V DC supply
  • Redundant power supply connections

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Scarica il Datasheet completo in formato PDF:


Estratto del Datasheet: Dati tecnici del  WHA-GW-F2D2-0-AS-Z2-ETH.EIP

Supply
Rated voltage20 ... 30 V DC SELV/PELV
Power consumption< 5 W
External bus
Connectionscrew terminals for
- 0.2 ... 4 mm2 (rigid wire)
- 0.2 ... 2.5 mm2 (flexible wire)
Interface 1Ethernet
10 BASE-T/100 BASE-TX , full galvanic isolation
ProtocolHART UDP, EtherNet/IP
Cable lengthmax. 100 m , depending on cables and transfer rate
ConnectionUTP, STP or FTP
Interface 2RS-485
ProtocolHART
Daisy-chain capabilitysupported by duplicated connection terminals
Transfer ratemax. 115 kBit/s
Cable lengthmax. 1200 m , depending on cables and transfer rate
Bus terminationintegrated termination resistor , adjustable via DIP switch and software
Input
Interfaceomnidirectional dipole antenna, removable
CommunicationWirelessHART specifications
- physical layer: IEEE 802.15.4.2006
- frequency band: 2.4 GHz (ISM band, licence free)
- transmission rate: 250 kBit/s
- maximum transmit power: +10 dBm (EIRP)
- transmission range: outdoor 250 m, indoor 50 m (under reference conditions)
- communication standard: WirelessHART acc. to IEC 62591
Galvanic isolation
Interface/power supplybasic insulation according to IEC 61140, rated insulation voltage 50 Veff
Interface/interfacebasic insulation according to IEC 61140, rated insulation voltage 50 Veff
Indicators/settings
Display elementsLED PWR (power supply status), one green LED
LED COM (communication status), three yellow LEDs
LED FLT (fault signal), one red LED
Control elements2 push buttons:
- restore HART configuration
- restore communication configuration
DIP switches:
- baud rate
- RS-485 address
- RS-485 termination
- security mode
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013
Radio and telecommunication terminal equipmentThe usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning.
Directive 2014/53/EUEN 300328: V2.1.1
EN 301489-17: V1.3.2
FCC CFR47 Part 15 B and CANSI C63.4-2003 , FCC ID: SJC-M2140
Conformity
Degree of protectionIEC 60529
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity5 ... 95 %, noncondensing
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
test setup and execution acc. to EN 60068-2-60
Mechanical specifications
Degree of protectionIP66/IP67
Massapprox. 1 kg
Dimensions258 mm x 114 mm x 84 mm
without antenna and cable glands
Mountingwall mounting
Data for application in connection with hazardous areas
EU-Type Examination CertificateFM 12 ATEX 0061
MarkingEx-Hexagon II 3 G Ex nA IIC T4 Gc
Directive conformity
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-15:2010
International approvals
FM approvalCoc3042646
Approved forNI Class I, Div. 2, GPS A-D
NI Class II, Class III, Div. 2, GPS E-G
IECEx approvalIECEx FMG 12.0002
Approved forEx nA IIC T4 Gc , Ex nAc T4
General information
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Classifications

SystemClasscode
ECLASS 13.027210990
ECLASS 12.027210990
ECLASS 11.027210990
ECLASS 10.0.127210990
ECLASS 9.027210990
ECLASS 8.027210990
ECLASS 5.127242692
ETIM 9.0EC001603
ETIM 8.0EC001603
ETIM 7.0EC001603
ETIM 6.0EC001603
ETIM 5.0EC001603
UNSPSC 12.139121008

Details: WHA-GW-F2D2-0-AS-Z2-ETH.EIP

Product Documentation: WHA-GW-F2D2-0-AS-Z2-ETH.EIP

Language Selection:
System DescriptionsLinguaFile tipoDimensioni
Patent InformationENGPDF365 KB
Brief Instructions
Brief Instructions - WirelessHART NetworkENGPDF2045 KB
Safety and Security Documentation
Manuale di istruzioniITAPDF126 KB
Manuals
ManualENGPDF11226 KB
Software Information
Software Release Notes WirelessHART GatewayENGPDF54 KB

Approvals: WHA-GW-F2D2-0-AS-Z2-ETH.EIP

Language Selection:
CertificatesCertificato NumeroLinguaFile tipoDimensioni
Canada FMCoC 3042646CALLPDF64 KB
Europe FM ATEX Category 3 GFM 12 ATEX 0061ALLPDF219 KB
FM Sealed Device nC Non-Sparking nA IECEx Certificate of ConformityIECEx FMG 12.0002ALLLINK---
Singapore IMDA Radio ApprovalN2700-20ALLPDF55 KB
USA FMCoC 3042646ALLPDF63 KB
Control Drawings
Control drawing FM / Control drawing FM   ALLPDF79 KB

Software: WHA-GW-F2D2-0-AS-Z2-ETH.EIP

Language Selection:
Device Description Files/Driversinformazioni sulla liberatoriaFile tipoDimensioni
AOP V1.8 for WirelessHART Gateway WHA-GW EIP Rev. 1 / AOP V1.8 für WirelessHART Gateway WHA-GW EIP Rev. 1ZIP76312 KB
EDS file WirelessHART Gateway WHA-GW EIP Rev. 1 / EDS-Datei WirelessHART Gateway WHA-GW EIP Rev. 1ZIP559 KB
DTM Collection WirelessHART V1.0.2.4 / DTM Collection WirelessHART V1.0.2.4ZIP22259 KB
Software Tools
Pepperl+Fuchs Discovery and Configuration Tool (PFDCT) / Pepperl+Fuchs Discovery and Configuration Tool (PFDCT)2.4.0.412ZIP4773 KB