Serviceline Industrial Sensors
Serviceline Explosion Protection

Vibration sensor VIM62PP-E1V16-0PE-I420V15

VIM62PP-E1V16-0PE-I420V15
  • Extended temperature range
  • Screw-in thread for simple installation
  • Simple electrical commissioning
  • Rugged stainless steel housing
  • Vibration velocity in mm/s via root mean square formation (rms)
  • Suitable for use in harzadous area up to Zone 1/21 with type of protection intrinsic safety

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

PDF 파일로 된 데이타 시트 다운로드:


데이타 시트 발췌: 기술 사양  VIM62PP-E1V16-0PE-I420V15

제품 설명
Vibration sensor with analog current output, increased temperature resistance, suitable up to Zone 1/21 with type of protection intrinsic safety
General specifications
TypeVibration sensor
Measuring technologyMEMS
SeriesPerformance Plus Line
Measured variableVibration velocity
Measurement range
Vibration velocity0 ... 16 mm/s
Measurement accuracy± 0.1 mm/s (calibration point: 90% of the measuring range; 159.2 Hz)
Complies with the tolerance requirements of DIN ISO 2954 for measurement range greater than 8 mm/s
Cross-sensitivity< 5 % of the partial lateral acceleration, which acts exactly 90° to the measuring axis
Frequency range10 ... 1000 Hz
Averaging timefor v-rms: 2 s
Electrical specifications
Fusingexternal fuse is required: 3 A , semi-time-lag , 30 V DC
Operating voltage10 ... 30 V DC
Current consumptionmax. 25 mA
Power consumptionmax. 750 mW
Time delay before availability10 s (rms filter is calculated intially with measurement data before they are available at the output)
Surge protectionup to 2 kV
Output 1
Output typeanalog output, current
output of the vibration variable
Output current4 ... 20 mA
Load resistor≤ 500 Ω
Standard conformity
Degree of protectionDIN EN 60529, IP66, IP67
Shock resistanceDIN EN 60068-2-27, 60 g, 6 ms
Vibration resistanceDIN EN 60068-2-6, 16.5 g, 10 ... 1000 Hz
Approvals and certificates
IECEx approval
Equipment protection level GbIECEx CSAE 22.0042X
Equipment protection level DbIECEx CSAE 22.0042X
ATEX approval
Equipment protection level GbCSANe 21 ATEX 1074 X
Equipment protection level DbCSANe 21 ATEX 1074 X
UL approval
Ordinary LocationE468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only.
adapters providing field wiring on request
Maximum permissible ambient temperaturemax. 60 °C (max. 140 °F)
Ambient conditions
Ambient temperature-40 ... 60 °C (-40 ... 140 °F)
Measuring head temperature-40 ... 125 °C (-40 ... 257 °F) directly at the mounting point
Storage temperature-40 ... 60 °C (-40 ... 140 °F)
Mechanical specifications
Connection typeplug
Housing materialStainless steel 1.4305 / AISI 303
Degree of protectionIP66 / IP67 only in connected state
Connector
ThreadingM12
Number of pins5
Massapprox. 200 g
Dimensions
Length82.35 mm
Diameter31 mm
General information
Use in the hazardous areasee instruction manuals
Only use accessories specified by the manufacturer.

Classifications

SystemClasscode
ECLASS 13.027271103
ECLASS 12.027201406
ECLASS 11.027201406
ECLASS 10.0.127201406
ECLASS 9.027201406
ECLASS 8.027201406
ECLASS 5.127201406
ETIM 9.0EC004309
ETIM 8.0EC004309
ETIM 7.0EC002959
ETIM 6.0EC002959
ETIM 5.0EC001758
UNSPSC 12.141114624

Details: VIM62PP-E1V16-0PE-I420V15

Informative Literature: VIM62PP-E1V16-0PE-I420V15

Language Selection:
Literature언어파일 타입파일 크기
Product Overview - Vibration SensorsENGPDF1351 KB

Product Documentation: VIM62PP-E1V16-0PE-I420V15

Language Selection:
Brief Instructions언어파일 타입파일 크기
Instruction leaflet / BeipackzettelALLPDF252 KB
Safety and Security Documentation
Instruction manualENGPDF219 KB
Manuals
Manual VIM6*-Vibration SensorsENGPDF2498 KB

Design / Simulation: VIM62PP-E1V16-0PE-I420V15

Language Selection:
CAD언어파일 타입파일 크기
CAD 3-D / CAD 3-DALLSTP1973 KB
CAE
CAE EPLAN Data Portal / CAE EPLAN Data PortalALLLINK---
CAE EPLAN macro EDZ / CAE EPLAN Makro EDZALLEDZ121 KB

Approvals: VIM62PP-E1V16-0PE-I420V15

Language Selection:
Certificates인증서 번호언어파일 타입파일 크기
Canada, USA UL Ordinary LocationE468231ALLPDF610 KB
Europe CSA ATEX Category 2CSANe 22 ATEX 1074 XALLPDF1221 KB
Worldwide IECEx Certificate of ConformityIECEx CSAE 22.0042 XALLLINK---
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-6808ALLPDF332 KB
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F)DOC-6850ALLPDF326 KB

관련문서: VIM62PP-E1V16-0PE-I420V15

Accessories
Mounting adapter for VIM3*/VIM6*/VIM8* vibration sensors, internal thread M8 x 1.25 x 10, external thread M8 x 1.25, screw-in depth 19.5fa
Protective rubber sleeve for VIM6* vibration sensors against ingress of moisture and mechanical effectsfa
Mounting adapter for VIM3*/VIM6* vibration sensors, internal thread M8 x 1.25 x 10, external thread M10 x 1.5, screw-in depth 18fa
Mounting adapter for VIM3*/VIM6*/VIM8* vibration sensors, internal thread M8 x 1.25 x 10, external thread M30 x 3.5, screw-in depth 45fa
Mounting adapter for VIM3*/VIM6* vibration sensors, internal thread M8 x 1.25 x 10, external thread NPT1/2", screw-in depth 24fa
EMC adapter for VIM3*/VIM6* vibration sensors, internal thread M8 x 1.25 x 10, external thread M8 x 1.25, screw-in depth 8fa
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA ... 20 mA, Terminals with test points, Up to SIL 2 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, HART communication, Test sockets, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 35 V DC, Field device: 2-wire transmitter, Field device [2]: 3-wire transmitter, Field device [3]: current sourcepa
Female cordset single-ended M12 gewinkelt A-coded, 5-pin, shield on pin 5, PUR cable 4-core blue, NAMUR, shielded, UL approved, drag chain suitable, oil resistantfa
Mounting adapter for VIM3*/VIM6* vibration sensors, internal thread M8 x 1.25 x 10, external thread M6 x 1.0, screw-in depth 10fa
Mounting adapter for VIM3*/VIM6*/VIM8* vibration sensors, internal thread M8 x 1.25 x 10, external thread M16 x 2.0, screw-in depth 27fa
Mounting adapter for VIM3*/VIM6*/VIM8* vibration sensors, internal thread M8 x 1.25 x 10, external thread M20 x 2.5, screw-in depth 34fa
Mounting adapter for VIM3*/VIM6*/VIM8* vibration sensors, internal thread M8 x 1.25 x 10, external thread M24 x 3.0, screw-in depth 40fa
Magnetic adapter for VIM3*/VIM6* vibration sensors, internal thread M8 x 1.25 x 10, holding force 35 kgfa