Serviceline Industriële Sensoren
Serviceline Explosiebeveiliging

Temperatuurmodules

Kies uw product

Product


4 channels, Inputs Ex ia, Mounting in Zone 2, Class I/Div.2 or in the safe area, Converter for 2-, 3- and 4-wire RTDs (Pt100 ... Pt1000), slide wire sensors etc., Explosion protection: Ex ia, Field device: resistance thermometer, Field device [2]: slide-wire sensors, Field device [3]: potentiometer, Connection: 2-wire sensor, Connection [2]: 3-wire sensor, Connection [3]: 4-wire sensorpa


4 channels, Inputs Ex ia, Mounting in Zone 2, Class I/Div.2 or in the safe area, Converter for thermocouples and mV-signals, Explosion protection: Ex ia, Compensation (reference junction CJC): internal cold junction compensation or external cold junction, Field device [2]: Thermocouple, Field device [4]: mV source, Compensation (reference junction CJC): internal cold junction compensation or external cold junctionpa

4 channels, Converter for 2-, 3- and 4-wire RTDs (Pt100 ... Pt1000), slide wire sensors etc., Installation in Zone 2 or safe area, Simulation mode for service operations (forcing), Explosion protection: Ex ic, Field device: resistance thermometer, Field device [3]: slide-wire sensors, Field device [5]: potentiometer, Connection: 2-wire sensor, Connection [2]: 3-wire sensor, Connection [3]: 4-wire sensorpa

4 channels, Converter for thermocouples and mV-signals, Installation in Zone 2 or safe area, Simulation mode for service operations (forcing), Explosion protection: Ex ic, Compensation (reference junction CJC): internal cold junction compensation or external cold junction, Field device [2]: Thermocouple, Field device [4]: mV source, Compensation (reference junction CJC): internal cold junction compensation or external cold junctionpa

1-channel, Input Ex ia, Mounting in Zone 2, Class I/Div.2 or in the safe area, Converter for 2-, 3- and 4-wire Pt100, slide wire sensors, Explosion protection: Ex ia, Field device: resistance thermometer, Field device [3]: slide-wire sensors, Connection: 2-wire sensor, Connection [2]: 3-wire sensor, Connection [3]: 4-wire sensorpa

1-channel, Input Ex ia, Mounting in Zone 2, Class I/Div.2 or in the safe area, Converter for thermocouples and mV-signals, Explosion protection: Ex ia, Compensation (reference junction CJC): internal cold junction compensation or external cold junction, Field device [2]: Thermocouple, Field device [4]: mV source, Compensation (reference junction CJC): internal cold junction compensation or external cold junctionpa

Filter Op

PROFINET-gateway

De nieuwe Zone 2-, Class I/Div. 2-gecertificeerde Remote I/O PROFINET-gateway van Pepperl+Fuchs maakt de weg vrij voor Industrie 4.0-toepassingen in procesindustrieën.